Install this product after discharging the drainage that has already accumulated in Mounting Example Compressor Aftercooler Air tank Main line filter Air dryer How to Order ADM200 Port size OUT IN Symbol 04 03 3 8 3 8 Construction/Dimensions 1 2 3 8 Voltage 100 VAC Hz 1 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC 12 VDC 2 3 4 5 6 7 Set screw Operating

(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.

(between lead wire and case) 1000 VAC for 1 min.

, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)

(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).

82 88 89 Breathing hole Note) 3.7 3.7 (M3 x 0.5) 13.7 1 SUP VAC EXH ATM OUT port (4, 5/32") Note) When used under conditions equivalent to IP65, use the regulator after piping a fitting/tube to the breathing hole.

VEX5511-062EZ-BG Body size 5, Select, External pilot solenoid Port size 3/4 200 VAC, Grommet terminal, with light/surge voltage suppressor OptionBracket, with pressure gauge 5 3 4 200 VAC 50/60 Hz 1 1 1 110 VAC 50/60 Hz 4 7 220 VAC 50/60 Hz 24 VDC 12 VDC 11 4 11 4 5 6 11 2 9 2 2 7 240 VAC 50/60 Hz Other 9 Option Thread type Nil F N T Rc G(1) NPT NPTF Note 1) Not conforming to ISO1179-1.

[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.

AC (50/60 Hz) Bracket CE-compliant 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Nil : Without bracket F : With bracket 3 port For type W, only DC voltage is available. Note) CE-compliant: For DC only. Actuation type Bracket 1 2 Normally closed Normally open Bracket is mounted. Brackets cannot be retrofitted. External pilot type is not available.

(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.

Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications

DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Bracket Nil: Without bracket F: With bracket AC (50/60 Hz) 3 port 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available. Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted.

IFW5 10 03 N 1 1 PSE Z I SE3 Diaphragm style flow switch PS Light 0 None Z I SE1 2 1 With neon light (110 VAC, Red) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting

[115 VAC] 220 VAC [230 VAC] Lead wire length 0.6 m Connector type Lead wire length 3 m Connector type Note) The connector box type and serial transmission type are only available with 5 (24 VDC).

Electrical entry Rated voltage G Grommet 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz C Conduit D DIN terminal 3 110 VAC 50/60 Hz T Conduit terminal 4 220 VAC 50/60 Hz 7 240 VAC 50/60 Hz Refer to the table (1) given below for availability. 8 48 VAC 50/60 Hz 9 Other (Only AC) Table (1) Rated VoltageElectrical Entry-Electrical Option Caution Insulation type Electrical entry Electrical option 1 (100

(50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.

Specifications CD-P12 CD-P11 100 VAC Part No. 200 VAC 24 VDC Load voltage 25 mA 12.5 mA 50 mA Maximum load current Lead wire length Switch conneciton side 0.5 m Load connection side 0.5 m (Example) D-F9PWVL61 Flexible specification Auto Switch Hysteresis Internal Circuit The hysteresis is the difference between the position of the auto switch as it turns on and as it turns off.

(50/60 Hz), 200 to 230 VAC (50/60 Hz) Reference page Page 607 * Copper and zinc materials are used for the motors, cables, controllers/drivers. 545 25A-LEm Series Specific Product Precautions Be sure to read this before handling the products.