VK300-82-2-01 100 VAC V100 VK300-82-2-03 110V 110 VAC 200 VAC 220 VAC VK300-82-2-02 200V VK300-82-2-04 220V S070 240V 6V 12V 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal VQD VQD-V Light (Built-in connector) Marking Circuit with light AC Circuit diagram 12 VDC or less Circuit diagram 24 VDC or more Circuit
ZSE ISE ZSP Fig. (2) Equivalent circuit of an NPN switch with the output off PS PLC Low level 12 to 24 [VDC] Main circuit of switch ISA Max. 80 [mA] Max. 30 [V] Load PSE Current flows. Load is powered. IS ISG Fig. (3) Equivalent circuit of an NPN switch with the output on ZSM PNP 12 to 24 [VDC] Fig. (4) shows an example of a PNP switch.
Setting of the response time may improve the condition. -86No.PF-OMX0002-B Error indication Problem Possible causes Investigation method Countermeasure Incorrect power supply Check if the power supply voltage is 24 VDC 10%. Power supply voltage is 24 VDC 10%.
Check if a voltage of 24 VDC is applied to the EMG terminal. Stop command Apply 24 VDC to the EMG terminal. 5 Check if the wiring is connected correctly or if there is broken wire or short-circuit by referring to this Operation Manual. Correct the wiring and check that the input/output of each signal is correct.
. -11No.EX-OMI0003-H Common Specifications EX510 series common specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal
ZNR ZNR 12 to 24 VDC SOL DC () 100 to 200 VAC SOL 2 DC () ZSE ISE 2 ( ) PNP open collector output Conduit terminal DIN type connector With indicator light AC Circuit Conduit terminal With indicator light DC circuit PSE DC (+) 1 ( ) 1 DC (+) MAX 80 mA Rectifying device Z I SE3 OUT Load 12 to 24 VDC ZNR ZNR 100 to 200 VAC 12 to 24 VDC SOL SOL DC () PS 2 ( ) LED 2 DC () indicator light Z I
Voltage Symbol Type 5 24 VDC 6 12 VDC Note) For symbol, refer to page 741.
12 VDC Note 1) Refer to the below table (1) for combinations with light/surge voltage suppressors.
LED of COM A-D does not light up if the port is not set to be "used" by input point setting. 24 VDC 24 VDC 24 VDC 17 16 Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off. Open the cover, and set DIP switch with a small flat blade screwdriver, etc. UNIT STATUS setting (switch No.8) The setting is as follows.
The proof pressure is double the operating pressure range. 0 0.25 0.5 1 2 5 Response time [s] 6 LFE Series Internal Circuits and Wiring Examples (Integrated Display Type) NPN 2 output type LFElAlll PNP 2 output type LFElBlll Brown DC (+) Brown DC (+) Load Black OUT1 Black OUT1 Main circuit Main circuit Load Load 24 VDC 24 VDC White OUT2 White OUT2 Load Blue DC () Blue DC () Max. 28 V, 80
: Analog output 1 to 5 V Allowable load resistance 100 k or more P5: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) P2: Analog output 1 to 5 V Allowable load resistance 100 k or more P6: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) 339 LLB Series Refer to the operation manual for how to set
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
VQZ Note) Rubber seal only 3-position closed center 2(B) (A)4 Coil voltage SQ 3 24 VDC 12 VDC 5 Note) 6 (R1)5 1 (P) 3(R2) VFS Note) Only 24 VDC is available with the S kit. 3-position exhaust center D Slide locking type (Manual) VFR 2(B) (A)4 Light/surge voltage suppressor 4 VQ7 Yes None (Non-polar) Nil E Note1, 2) (R1)5 1 (P) 3(R2) Note 1) Not applicable to the S kit.
0.01 to 0.1 VDC 3.7 to 4.3 mA DC 0.02 to 0.2 mA DC 1 to 5 VDC 0 to 10 VDC 4 to 20 mA DC 0 to 20 mA DC 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 Note 1) Enter symbols above in VY1D00-.
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
the power supply voltage is 24 VDC) Output type Analogue output 6 Current output: 4 to 20 mA (Refer to analogue output graph) Voltage output Output impedance approx. 1 k Impedance Maxi. load impedance: 600 at 24 VDC Current output 300 at 12 VDC Mini. load impedance: 50 Response time 7 Linked with the response time of the switch output.
supply voltage is 24 VDC) Output type Analogue output 6 Current output: 4 to 20 mA (Refer to analogue output graph) Voltage output Output impedance approx. 1 k Impedance Maxi. load impedance: 600 at 24 VDC Current output 300 at 12 VDC Mini. load impedance: 50 Response time 7 Linked with the response time of the switch output.
Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply EX260-SPN1/-SPN3 PNP (negative common) / source Output type EX260-SPN2/-SPN4 NPN (positive common) / sink Solenoid valve connecting specification Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1.0 W or
FG Connect the grounding cable. 24V Connect the power supply cable 24 VDC for solenoid valve. 0V Connect the power supply cable 0 VDC for solenoid valve. N.C. Blank terminal -11No.EX-OMC0002-C Wiring for communication cable There are two methods of CompoBus/S slave connection, T branch type and Multi drop type.