SMC Corporation of America
Elite Part Number Search
Search Results "RS2H80A-40BM-DC"

Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.

D-F9BV D-F9PV D-F9NV D-F9B D-F9P D-F9N DC(+) Brown [Red] Lead wire length: 0.5m 6 7 7 6 7 7 Lead wire length: 3m 31 37 37 31 37 37 Main circuit of switch OUT Black [White] DC() Blue [Black] Dimensions D-F9N, D-F9P, D-F9B D-F9P(V) M2.5 x 4 Slotted set screw DC(+) Brown [Red] 2 Indicator light Main circuit of switch 2.7 2.8 22 OUT Black [White] 2.6 4 DC() Blue [Black] Most sensitive position

DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V E 15 V 1 k F420 mA 12 V 300 24 V 600 Max.28 V80 mA 1 V C 15 V 1 k D420 mA 12 V 300 24 V 600 -18No.PF-OMN0011CN-C NPN PF3W30G PNP PF3W30H DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V 30 ms Max.28 V80 mA 1 V 30 ms 2 PF3W30J/PF3W30K DC(+) DC(-) / J15 V 1 k K420 mA 12 V 300 24 V 600 -19No.PF-OMN0011CN-C

MN MO Without lead wire (Applicable to DC only) Without connector Grommet type G H Lead wire length 0.3 m (Applicable to DC only) Lead wire length 0.6 m (Applicable to DC only) Air operated Nil Note) In the case of K1 or J1 (combination of supply and release valves), M type plug connector can not be used.

Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.

D-F5PW, D-G5PW, D-H7PW D-F7PW, D-Y7PW(V), D-F9PW(V) D-F59, D-F79, D-F7NV, D-G59 D-H7A1, D-Y59A, D-Y69A, D-F9N(V) D-G59W, D-F59W, D-H7NW D-F7NWV, D-F79W, D-F9NW(V) D-Y7NW(V) DC(+) Brown [Red] DC(+) Brown [Red] DC(+) Brown [Red] Main circuit of switch Main circuit of switch OUT Black [White] OUT Black [White] OUT Black [White] Main circuit of switch DC() Blue [Black] DC() Blue [Black] DC()

DC (+) (Brown) DC (+) Sensor input: +1 to 5 VDC DC () Excess current is flowing into the switch output of OUT2.

Use of incorrect power supply will cause damage to equipment. 1 DC (+) ZSP ZNR 12 to 24 VDC SOL PS 2 DC () LED ISA Wiring PSE IS Individual wiring Centralized wiring Terminal block ISG 1: Brown 2: NC 3 0 1 2 3 4 Brown Blue Black DC (+) NC DC () OUT OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 ZSM 6 9 3: Blue DC () NC DC (+) OUT 6 4: Black 1.

(Maximum transmission distance 4 m) Master Slave (source of copy) (copy destination: up to 10 switches) Slave side (copy destination) 3-Color Display Digital Flow Switch for PVC Piping Master n units 1 unit 2 units (source of copy) (up to 10 switches) DC () COPY OUT2 OUT1 DC (+) DC () COPY OUT2 OUT1 DC (+) DC () COPY OUT2 OUT1 DC (+) DC () COPY OUT2 OUT1 DC (+) Brown Brown Brown Brown Blue

FUNC Blue DC () Blue DC () Output specification C NPN (1 output) + Analog voltage output Output specification D NPN (1 output) + Analog current output Brown DC (+) Brown DC (+) Load Load Load Load Black OUT1 Black OUT1 Main circuit Main circuit + + White OUT2 Analog output White OUT2 Analog output 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () Output specification E PNP (

24 VAC/DC or less: 50 mA 48 VAC/DC: 40 mA 100 VAC/DC: 20 mA VS4 Max. switch capacity Note 1) Voltage: 24 VDC to 100 VAC Inner voltage drop: 4 V Note 2) Combination of a valve VFS41 (single) and a release valve spacer can be used as an air release valve.

Gasket and Screw Assembly DC positive common Part no.

(+) 5 OUT1 4 OUT2 3 (FUNC) 2 DC(-) 1 -18No.PS-OML0002CN-G Z/ISE30A(F)--DC(+) OUT -N NPN 1 Max.28 V80 mA 1 V FUNC DC(-) DC(+) OUT -P PNP 1 Max.80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -A NPN 2 Max.28 V80 mA 1 V FUNC DC(-) DC(+) OUT1 OUT2 -B PNP 2 Max.80 mA 1 V FUNC DC(-) -19No.PS-OML0002CN-G DC(+) OUT1 -C OUT2 NPN 1 Max.28 V80 mA 1 V 1 k FUNC DC(-) DC(+) -D

) Orange [Yellow] OUT Black [White] OUT() Blue [Black] DC() Blue [Black] DC() Blue [Black] D-J59 D-F5BAL D-F5NTL OUT(+) Brown [Red] OUT(+) Brown [Red] DC(+) Brown [Red] Main switch circuit Main switch circuit Main switch circuit OUT Black [White] OUT() Blue [Black] DC() Blue [Black] OUT() Blue [Black] D-F59W D-J51 D-G39 DC(+) Brown [Red] DC(+) Terminal 1 Main switch circuit Main switch circuit

The allowable voltage fluctuation rate is 10% of the rated voltage value for both AC and DC. When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXD21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC.

the 5-pin type, only DC voltage is available.

(+) Power supply + Power supply cable 2 wires AWG20 (20 lines/0.16 mm2) 24 VDC Blue DC (-) I/O cable Symbol Color Signal name Contents Brown DC (+) DC (+) Brown Vcc GND Power supply cables for driving the actuator Pink OUT1 Load DC () Blue Main circuit Main circuit Power supply for signals Orange OUT2 Load 24 VDC + I/O cable 9 wires AWG28 (7 wires/0.127mm2) Yellow OUT3 Load Green OUT4 Symbol

Brown (2cables) DC() +24V +24V 24 VDC DC/DC Power supply Blue (2 cables) DC() Power supply 0V 0V 24VDC F.G. Be sure to ground.

Flow switch Blue (DC COM) Brown (DC 24V) Brown (DC 24V) Terminal No. 14 6 Terminal No. Flow switch 5 Terminal No. Blue (DC COM) 11 Terminal No. Black (Output1) 3 Terminal No. Black (Output1) Fig. 3-14 Wiring of the external switch (NPN open collector output) (example) Flow switch Blue (DC COM) Brown (DC 24V) Brown (DC 24V) 14 Terminal No. Blue (DC COM) 6 Terminal No.

DC VZ Red Diode VS Black Molded coil VFN Groove Pin DC polarity indicator L/M Plug Connector Type Cover AC Lever Coil Type L DC coil: + Red, Black Pin Black DC Lead wire Diode Coil Coil Coil Red Connector Socket part no.