SMC Corporation of America
Elite Part Number Search
Search Results "RS2H63-30DL-D-M9N"

D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV U A B [mm] Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV A B 12 5 2.5 16 5.5 3 20 6 6 25 6 7.5 32 8 8 40 11 9 50 11.5 11 63 13.5 13.5 80 16.5 18 100 19.5 21 Auto switch model Auto switch model D-M9mV Bore size Bore size U 12 19.5 16 21 20 23 25 24.5 32 28.5 40 31.5 50 36.5 63 43 80 52.5

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

.) < Applicable Auto switches > Solid state auto switch D-M9N(V)-900M9P(V)-900M9B(V)-900 D-M9NW(V)-900M9PW(V)-900M9BW(V)-900 Reed auto switch D-A90-900 Fig 4. How to Mount and Move the Auto Switch Fig 4.

Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5

When auto switches D-M9/M9W/Y59 D-M9A D-Y7, Y7W are used A B L Auto Switch Hysteresis MHZ When auto switches D-M9V/M9WV/Y69 D-M9AV D-Y7V, Y7WV are used Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. MHF A B MHL L MHR MHK MHS Max.

(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.

P.336 P.1785 (/) (/) 19 18-2. 12 16 20 25 32 40 50 63 80 100 1 2 1 2 1 15 2 15 1 15 2 15 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 10 15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.

Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide

current Application Indicator light Electrical entry the cylinder IC circuit DC4.528V , Relay Tie-rod D-M9N-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod D-M9NV-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod D-M9P-900 Yes Grommet Max.40mA Sequence mounting controller IC circuit DC4.528V , Relay Tie-rod

D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable

type D-Z7 type Note 1) Note 1) D-Z8 type D-A9 type D-F9 type D-Y6 type D-Y7 type Note 1) Vertical outlet types cannot be mounted.

Proper Auto Switch Mounting Position (Detection at stroke end) MX A B MTS MY MY3A D-A9, D-A9V (mm) D-F9W, D-F9(W)V (mm) D-M9, D-M9V (mm) CY A B Operating range Bore size 16 25 40 63 A B Operating range Bore size 16 25 40 63 B Operating range Bore size 16 25 40 63 A 088.5 084.5 26.5 084.5 22.0 26.5 2 06.5 3.0 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.

MDHR3-10 1122MDHR3-15 1122H L H When auto switch D-M9V is used When auto switch D-M9 is used When auto switch D-M9V is used Max. protrusion of auto switch from edge of body: L, H Max. protrusion of auto switch from edge of body: H (mm) (mm) D-M9 D-M9V D-M9V Auto switch model Auto switch model L H 1.3 The auto switch will not protrude in the case of D-M9. 2.3 H 939 Rotary Actuated Air