SMC Corporation of America
Elite Part Number Search
Search Results "RDLQA63TF-75-B"

D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30

AB AH AO AT B E EE LF+ P+ S SA+ WF XA+ 500 (5") 1.000 3/4-16 1.13 .63 2.75 .63 .19 1.500 5.50 1/2 NPT 4.50 2.88 4.25 7.88 1.38 7.25 600 (6") 1.375 1-14 1.63 .75 3.25 .63 .19 2.000 6.50 3/4 NPT 5.00 3.13 5.25 8.50 1.63 8.00 800 (8") 1.375 1-14 1.63 .75 4.25 .69 .25 2.000 8.50 3/4 NPT 5.13 3.25 7.13 8.75 1.63 8.56 MS2 Side lug style (S) LF + Stroke WF A P + Stroke 2-EE KK B MM LH ST TS SB

Material: Carbon steel 20 Series MU Auto Switch Proper Mounting Position (Detection at stroke end) and Mounting Height D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V B B A A Hs Hv D-M9 D-M9W D-M9AL D-M9V D-M9WV D-M9AVL D-A9 D-M9V D-M9WV D-M9AVL Size A B A B Hs Hv A B A B Hs Hv 25 5 5 5 5 7.5 27.5 1 1 1 1 32 5 5 5 5 14.5 30 1 1 1 1 40 5.5 5.5 5.5 5.5 16.5 37 1.5 1.5 1.5 1.5 50 7

How to Order S 2 B P H S4 200 LEY 63 A2 w y !0 i o e r t q u !1 !2 !3 !

B B B B B B AW20K-D 30 34 43.9 5.4 15.4 55 2.3 29.7 28.5 14 6 104.9 91.4 87.4 93.9 AW30K-D 41 40 46 6.5 8 53 2.3 31.3 38.5 19 7 157 123.9 122.2 117.8 122.3 137.8 142.3 AW40K-D 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 186.9 155.6 153.9 149.5 154 169.5 174 AW40K-06-D 50 54 55.5 8.5 10.5 70 2.3 35.5 42.5 21 7 188.9 157.6 155.9 151.5 156 171.5 176 AW60K-D 70 75 66 11 22 113 3.2 273.9 242.6 240.9

OUT OUT Proper Auto Switch Mounting Positions (Stroke End) Proper Auto Switch Mounting Positions(Series CE1) Auto switch (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 41 47.5 55.5 79.5 82.5 86 D-A7lH, A80H, A73C, A80C, D-F7l, J79, F7lV, J79C 4.5 13.5 17.5 39.5 44.5 42 A B 38 44.5 52.5 76.5

DXT170-75-1 Connection/Disconnection of socket with lead wire Connection Insert lead wire and crimped socket into square holes (Indicated as A,B, COM) of connector. Press the socket in fully until the hook of the socket locks into the groove of the connector housing. Confirm the locked positon by lightly pulling on the lead wire.

Gasket DXT192-10-5 (Use caution to the orientation.) 3-3-30 5 Port Solenoid Valve Base Mounted Series VZ3000 Flow Characteristics/Weight Flow characteristics (1) Port size Valve model Type of actuation Weight (g) 1 4/2 (P A /B) 4, 2 (A, B) 1, 5, 3 (P , EA, EB) 4/2 5/3 (A/B EA/EB) b C [dm3/(sbar)] Cv C [dm3/(sbar)] Cv b Grommet 125 (75) 170 (120) Single Double Closed center Exhaust center

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.

Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.

FT FX (mm) FZ Stroke range Bore size (mm) B FT FD FX FY FZ 40 50 63 12 16 16 80 100 112 58 61 75 100 125 138 9 9 12 74 78 100 to 1000 to 1000 to 1000 Rear flange type (G) 4-FD FY B FX FT ZZ + Stroke FZ (mm) Stroke range Bore size (mm) B FT FD FX FY FZ ZZ 40 50 63 12 16 16 80 100 112 58 61 75 100 125 138 9 9 12 74 78 100 190 211 237 to 1000 to 1000 to 1000 4 Series MGZ Construction Parts

Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)

Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)

a) .250 \-24 0.50 .624 .621 0.25 0.86 0.38 it-l6 .251 .zfi 0.75 0.25 o.34 It.oo o.75 o.62 o.12 # 1 8 o.75 1-?

Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

E s .9 6 5 o 25 50 75 Inpul siqnal (%F.s.) l 25 50 75 Inpul signal (%F.S.)

Bore size (Stroke (mm)) 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 6 8 12 16 20 25 Functional option Standard With buffer With end lock Axial piping type With buffer and end lock With buffer, Axial piping type Nil F R (2) P FR (2) FP Adjuster option Note