Without driver Cable length A1 A2 B1 B2 Right Pulse input type (Incremental encoder) 100 V Pulse input type (Incremental encoder) 200 V 2 5 Left Top 2 m 5 m Axial entry Right entry Pulse input type (Absolute encoder) 100 V Pulse input type (Absolute encoder) 200 V Bottom entry A Bottom 10 m Cable entry direction Specifications 200 16.0 300 18.0 400 20.0 500 22.0 600 24.0 800 28.5 1000 1200
/min (ANR)) Supply pressure P1 (MPa) Relief flow rate (L/min (ANR)) IR2020-02 IR2020-02 IR2020-02 Supply pressure: 1.0 MPa Back pressure: 1.0 MPa IC 1.0 0.8 0.204 ITVH 0.9 Set pressure P2 (MPa) Set pressure (MPa) 0.7 Set pressure (MPa) 0.8 0.6 ITVX 0.202 0.7 Set point 0.5 0.6 PVQ 0.200 0.5 0.4 0.4 0.3 VY1 0.3 0.198 0.2 0.2 VBA VBAT 0.1 0.1 0.196 0 200 400 600 800 0 200 400 600 800 1000 1200
23 46 50 56 50 63 06 FGDFB FGESA Note 2) 410 3000 45 90 120 140 100 160 10 FGELA Note 2) 410 3600 50 120 140 170 110 210 20 FGETA FGESB Note 2) 800 3300 70 140 150 160 120 170 10 FGELB Note 2) 800 4200 90 170 180 210 140 230 20 FGETB FGESC Note 2) 1100 3400 83 150 160 170 120 170 10 FGELC Note 2) 1200 4400 120 190 200 220 150 230 20 FGETC FGGSB 160 270 300 320 290 360 FGGLB FGGSC 200
I , ~ R. t:l' t y X BN N X Y 1 S + Stroke H LS + Stroke ZZ + Stroke Long Stroke Bore size Stroke ) (mm) range (mm) RT RV 40 501-800 50 601 1000 1001 1200 30 76 , 63 601-1000 1001-1200 40 92 80 751-1000 1001 1400 45 112 100 7511000 . . .
AZ1300 150 psig (1.0 MPa) 75 psig (0.52 MPa) Inlet pressure: 100 psig (0.69 MPa) 40 0.28 140 0.97 35 0.24 120 0.83 Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig) Delivery pressure (psig) 30 0.21 100 0.69 25 0.17 80 0.55 20 0.14 60 0.41 15 0.10 40 0.28 10 0.07 20 0.14 5 0.03 0 0.00 0 0.00 0 100 200 300 400 500 600 700 Flow rate (slpm, N2) 0 200 400 600 800 1000 1200
1200 1 ,4QO , 80 25, 50, 7~ 100, 1 25, 150. 1 7~20~ 250,300, 350, 400,450.500, 600, 700, 800 100 1500 25, 50.75, 100, 125, 150,175,200, 250,300, 350,400,450,500,600,700,800 Intermediate strokes are available.
Recommended shim thickness) Arm length L: 10 in 0.14 0.04 0.10 1600 1400 1200 1000 800 600 400 200 0 Clamping force (lbf) 0.7MPa 0.5 MPa 0.3 MPa 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 187 Model Selection 2 Slim-line power clamp cylinder mounting When using a hard stop Arm length L (Distance to a hard stop) Clamp arm Cylinder Shim q Upper hard stop Clamping block Clamp arm Unclamping
126 32 90 110 105 126 4 CKZT -X2797 -X2798 Dimensions: Clamp Arm CKZT25-A000 S-X2797 C R L L: Left 26 18 52 40 16 C: Center R: Right 200.1 2 x 4H7 through 200.02 (8) 28 2 x 6.5 through 93 44 10 200.1 5 CKZT -X2797 -X2798 Model Selection Relation between arm length and clamping force Arm length Clamp arm Shim Clamping block Extension arm Fulcrum Load cell Bore Size: 25 Bore Size:32 270 [1200
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Intermediate strokes are available.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Flow-rate Characteristics Note) Values when the main valve is fully open Male thread nozzle High efficiency nozzle 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 400 VMG1-R02-400:4 KNH-R02-200 VMG1-R02-350:3.5 350 VMG1-R02-300:3 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 300 KN-R02-250:2.5 KN-R02-200:2 250 KN-R02-150:1.5 KNH-R02-150 200 KN-R02-100:1 150 KNH-R02-100
conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VZS3000 Model VK 1 4/2 (P A/B) C [dm3/(sbar)] C [dm3/(sbar)] b Cv 4/2 5/3 (A/B R1/R2) Flow characteristics (1) Response time (ms) (2) Weight (kg) (3) Max. operating cycle (CPM) Port size Rc VZ Model Type of actuation b Cv VF 2 position VZS3150 1200
Heater assembly quantity 200/40 200/50 400/100 600/150 800/220 1200/350 100V H4 100C Heater assembly quantity used Heater power W (Nominal value) In-rush/Power consumption (Option symbolOperating voltage) 800/40 800/50 1600/100 2400/150 3200/220 4800/350 200V 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs. 3 pcs. 4 pcs.
RSH20, 32 Graphq Graphw 1.0 RSH32 RSH32 RSH32 Bore size 50, 63, 80/ m =0 Bore size 50, 63, 80/ m =0.1 RSH20 RSH20 RSH20 0.9 Operating pressure : P (MPa) 1300 1300 0.8 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 800 800 0.2 50 Weight : W (kg) Weight : W (kg) 700 700 0.1 600 600 100 200 300 400 500 0 63 500 500 Lateral load: W (N) 50 400 400 RSH50, 63, 80 300 300 1.0
Standard Stroke Standard stroke (mm) Bore size (mm) Max. stroke 32 700 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Made to Order Specifications (For details, refer to page 6-17-19.) 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50,
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Intermediate strokes are available.
MB1 Standard Stroke Bore (mm) CA2 Standard stroke (mm) Max. stroke 32 CS1 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 C76 Made to Order Specifications (For details, refer to 6-6-39.) 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125,
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250,
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 16 100, 200, 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1400, 1600, 1800, 2000 3000 25, 40 5000 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. When exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards