Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: High-pressure w/Power Saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: M6, PVDF, Lead Wire Length: -, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material/Port Size: Rc1/8, PVDF, Lead Wire Length, Electrical Entry, Light/Surge Suppressor: -, CE Compliant: -

Model: 21, Orifice Diameter: 2 mm, Valve/Body Configuration: N.C. for Manifold, Solenoid Valve Option: Brass Body, FKM Seal, Class B, Suffix: Standard, Manifold Designation: Brass, Stainless Steel Base Material, Voltage: 24VDC, Lead Wire: Conduit

Dispense Volume: 100 to 200 μL, Type: Body Ported, Voltage: 24 VDC, Fluid Contact Material: Body: PP; Diaphragm: EPDM; Check Valve: EPDM, Port Size: M5

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 2, Insulation Class: B, Pipe opening type (details): Base Mounted Type, Voltage: 24 V DC, Power

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Series: 2 (VQ2000), Actuation: 5 (3 Position Pressure Center), Body: 0, Seal Type: 1 (Rubber Seal), Function: VQ2: Standard, 0.4 W; VQ5: Standard, 0.95 W), Coil Voltage: 5 (24VDC), Electrical Entry: None, Light/Surge Suppressor: Yes, Manual Override: C (Locking Type, Manual), Enclosure: Dustproof

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

The VX3000 series is a direct operated, 3 port solenoid valve, for use with a wide variety of fluids. When used in combination with the manifold, configuration can be changed from N.C. to N.O. and from N.O. to N.C. by simply changing a gasket. Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure

SMC has developed the VXE series energy saving type, 2 port solenoid valve to help with environmental issues.  The PWM (Pulse Width Modulation) method was used to allow for less power consumption.  By reducing the energy consumption we have also reduced the heat produced by the coil. This series is available in three styles VXE directed operated, VXED pilot operated, and VXEZ zero differential

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 1 (Bracket)

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 1 (Bracket)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 2 (Manual Override)