, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 12-REA63 Note 1) Stroke exceeding the standard stroke will be available upon request as special product.
Standard motor LJ1H202NF-K 100W to 250 [Tamagawa Seiki Co., Ltd.]
, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
Standard motor LJ1H202NF-K 100W to 250 [Tamagawa Seiki Co., Ltd.]
20 2BFlange 30 3BFlange 40 4BFlange 20 2BFlange 30 3BFlange 40 4BFlange Shape Piping support style Standing style 60 6BFlange How to Select Max.
CAT.ES20-148 A Clean Room Rodless Cylinder Series CYP 15, 32 Magnetically coupled rodless cylinder for transfer in clean environments Low particle generation: 1/20 Long strokes (Max. 700mm) (compared to previous series) High cleanliness is achieved with non-contact construction of the cylinder tube exterior and a stainless steel linear guide (specially treated).
N333 Clean Room Rodless Cylinder CYPSeries 15, 32 Magnetically Coupled Cylinder w/Guide Shock-Free Cushioning Structure Low Particulate Generation Cleaned, Assembled & Double Packaged in a Clean Room A Low particle generation: 1/20 Long strokes (Max. 700mm) (compared to previous series) P High cleanliness is achieved with non-contact construction of the cylinder tube exterior and a stainless
N333 Clean Room Rodless Cylinder CYPSeries 15, 32 Magnetically Coupled Cylinder w/Guide Shock-Free Cushioning Structure Low Particulate Generation Cleaned, Assembled & Double Packaged in a Clean Room A Low particle generation: 1/20 Long strokes (Max. 700mm) (compared to previous series) P High cleanliness is achieved with non-contact construction of the cylinder tube exterior and a stainless
Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS 10kFF) 2B (JIS 10kFF) 3B (JIS 10kFF) 4B (JIS 10kFF) 4B (JIS 10kFF) 14-16-2
Particle generation has been reduced to 1/20 compared to series 12-CY1B (previous SMC product) even without vacuum suction. MX Shock-free A sine cushion is used at the end of the stroke. Smooth acceleration and deceleration are possible at 0.5 G or less.
Ambient temperature 0 to 40C (No freezing) Ambient humidity 35 to 65%RH (No condensation) Material Case: PBT Emitter: Tungsten Weight (Body only) Standard nozzle 200 g Bypass nozzle 250 g Standards/Directive CE (EMC directive, RoHS directive), UKCA Ambient humidity 20 to 80%RH Safety standards IEC 62368-1 *4 An AC cord included with an AC adapter is only for use in Japan.
Maintenance P.17 1) Inspection P.17 2) Overhaul P.18 3) Disassembly P.18 4) Assembly P.19 5) Expendable supplies P.20 6) Replacement procedure of seal P.21 7) Inspection P.22 5. Troubleshooting P.23 6. Construction P.26 7.
Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3
Tighten the panel nut by hand without the use of tools. 3 Regulator for 2 MPa ARX 20 Options Pressure gauge Instructions for Pressure Gauge with Limit Gauge Indicators Dimensions B Removing the Cover Grasp the outer edge of the front cover with your fingers, push it in while turning to the left (about 6 to 7mm) until it stops, and then pull it off.
The Cv factor for valves with back pressure check valve will be about 20% less than in the table above. Vibration resistance: No malfunction when tested with one sweep of 8.3 to 2000Hz in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 1 4 3 8 4.1-71 Direct Air Operated 3 Port Valve/Manifold Series VVXA31/32 For Air, Gas, Vacuum and Oil Compatible with a wide variety of fluids.
220 200 140 30 60 2 x M8 x 1.25 thread depth 13 (External cover mounting screw) 11.5 4 x 13 through 4 x 11 4 x 20 counterbore depth 8 (Mounting hole) 18 (Clamp block mounting hole) 500.03 2 x 8H7 +0.015 0 14 117 45 23 35 20 140 40 10 118 82 17 15 46 200 170 20 114 436 W-R3-SPosition of fulcrum 2 x 18.5 Proximity switch mounting bracket 74 Proximity switch (Option) 158 65 2 x Rc3/8 14 12
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Supply pressure: 0.5 MPa IR1000-01 IR1000-01 IR1000-01 Back pressure: 0.5 MPa 0.5 0.204 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 0.15 Set point 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 40 20 80 60 100 140 120 0 50 100 200 250 150 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8
210 350 440 Large flow type (-T) 40 m 120 180 230 380 250 480 660 80 m Weight [kg] 0.08 0.18 0.36 Note 1) The size of solid particles collectable by the element 40 m (80 m) shall be 40 m (80 m) or more in depth x height x width.