Power supply Residual Load voltage at ON = voltage voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Example: Power supply is 24 VDC.
Note 2)For interface use, supply 24 VDC o10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions. When it is OFF (alarm occurs), stop the sequencer signal using the sequence program.
Size: 10 3 mounting holes with the marks are for tightening the actuator and not to be used for external mounting. 3 x M3 x 0.5 (Depth 6) 24 Chamfer (Rotation range is stated on page 54.) A port B port 29 9h9 0 0.036 4g7 0.004 0.016 0.5 2 x M3 x 0.5 9 24 14 29 3.6 3 9.5 9.5 1 18.5 19.8 35 67 2 15 When D-M9m is used *1.
Description Decimal Common Format "Data-INT" "Data-SINT" Input 100 100 Output 150 150 Configuration 105 105 (5) Size: Perform setting as shown below.
D I M E N S I O N S ( I N C H) S TA N D A R D S I N G L E A C T I N G S P R I N G E X T E N D D O U B L E C L E V I S T Y P E NCJ2D_-_T ZZ 50 100 150 200 300 400 500 3.73 3.94 4.23 4.71 3.91 4.12 4.41 4.89 5.31 5.92 6.69 *Clevis Pin Included S Z D GA NB U Bore Size A B C CD CX MM NA R 50 100 150 200 300 400 500 50 100 150 200 300 400 500 H 0.157 0.31 0.93 0.31 10 (3/8) 0.60 0.47 0.55 0.187
Auto Switch Weights Unit: g Auto Switch Internal Circuits Lead wire length Model 3m 5m D-P5DWL 150 240 Indicate "Z" at the end of the model number for 5m lead wire.
Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.
Rod Couplers Part # Rod Thread DMA-312 5 16-24 DMA-375 38-24 DMA-437 7 16-20 DMA-500 12-20 The Table on the right shows the Rod Couplers that offers. The thread shown is a male / female thread as the coupler has both a male and female end.
L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 EXH port silencer 63 Silencer is installed in the EXH port. 38 22 13 Silencer P/N Model VQZ100 VQZ200 VQZ300 NAN110-N01 NAN110-N01 NAN200-N02 NAN200-N02 NAN110-N01 24 Q Q Q Technical Reference 35 19.4 Q Q Series VQZ100200300 Q 5 5
600 300 150 1000 500 250 800 400 200 Different from the initial value. *5.
Application Weight (g) Model Actuator Polyacetal roller 110 140 150 150 160 220 210 220 210 220 200 VM430-01-00 VM430-01-01 VM430-01-01S VM430-01-02 VM430-01-02S Basic VM-08A VM-07AS VM-07A VM-06AS VM-06A VM-05A VM-02AS VM-02A VM-01AS VM-01A Mechanical operation Manual operation Roller lever Hard steel roller Polyacetal roller Hard steel roller One way roller lever Straight plunger VM430
Cutout window View A-A' Mounting Standard Stroke GK BP A AA AB AG AH AI AJ AK AL AM AN AO AP B BZ GC GD Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 11 13 75 32 28 54 134 150 108 140 M 8 135 110 4 9 9 104 86.5 15 16 88 37 29 62 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 15 16 88 37 30 62
Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30
ZPR10D 10 16 12 18 15 16 24 25 32.9 33.9 49 50 5 6 6 7 ZPR16D Applicable Tubing Applicable tubing O.D.
PE 12 E Bracket Main port R J D 1 2 3 I O M C N H B P: For mounting 4 locations G A Air Operated Type A B C D E F G H I J K L M N O Model SGHA130-10 SGHA230-3015 SGHA230-7015 SGHA330-3020 SGHA330-7020 SGHA430-3025 SGHA430-7025 Main port Pilot port 3 x 3/8 1/8 60 28 46 133 34 60 24 29 142 37.5 75 62 6.5 33 3 x 1/2 1/8 60 28 48 135 34 65 24 29 144 37.5 75 62 8.5 35 3 x 1/2 1/8 77 33 49 150
Applicable strokes: 150, 250, 350, 450 Example) LJ1H1011PB-150-F2-X2 Body weight Operating temperature range Work load Rated thrust Maximum speed Positioning repeatability Motor Encoder Lead screw Guide Motor/Screw connection Model Performance 0.02 AC servomotor (50W) Incremental system Ground ball screw 12mm, 12mm lead High rigidity direct acting guide With coupling LC1-1B1H(Refer to page
VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard) Monitor unit Monitor unit Monitor unit Monitor unit 3% F.S. (15 to 35C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) (15 to 35C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S.
/30 m/s2 (2) Shock/Vibration resistance IP65 (Dusttight, Low jetproof) Enclosure 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 12 VDC, 24 VDC, 100 VAC, 110 VAC, 200 VAC, 220 VAC (50/60 Hz) Coil rated voltage 10% of rated voltage Allowable voltage fluctuation 2 position double (Rubber) 3 position closed center Class B or equivalent Coil insulation type (A) 4 (B) 2 (A) 4 (B) 2 1 W DC (42 mA) 24 VDC
(mm) Electrical entry P Port size B C D E F H K L M N A Grommet: G Conduit: C Conduit terminat: T Model Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 27 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 27 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
to 3000 L/min 0 to 1 L/min 0 to 3 L/min 1 to 1 L/min 3 to 3 L/min 10 to 1000 L/min 1 to 50 L/min 10 to 100 L/min 20 to 200 L/min 300 to 6000 L/min 2 to 100 L/min 600 to 12000 L/min Power supply voltage 24 VDCp10% 24 VDCp10% 12 to 24 VDCp10% 12 to 24 VDCp10% (25C reference) characteristics p3%F.S.(15 to 35oC) p2%F.S.