When an old IZN10 series ionizer was installed close to the main unit (manifold mounted), there was a possibility that the output (signal/LED) might malfunction due to the generation of high-voltage PCB noise by the ionizer.
As a countermeasure, a shielding sheet was made available (model: IZN10-A004).
New IZN10 series ionizers do not require a shielding sheet because countermeasures
If the PWR and NDL LEDs on the main unit are blinking green and the ION/HV LED is blinking red, there is a possibility of malfunction. This may be caused by noise in the CPU.
Possible countermeasures include ① moving the ionizer away from the noise source, ② separating wiring if the power line and ionizer are wired together, and ③ install a noise filter in the ionizer power supply.
When the NDL LED on the IZN main unit turns ON (orange or green), this indicates a maintenance warning. Due to contamination, wear, or damage to the emitter, the static neutralization performance may have decreased.
When a maintenance warning occurs, the ionizer main unit will continue to operate, but it is necessary to clean the emitter or replace the emitter assembly. In order to clear
Confirm that the ground terminal is grounded (100 Ω or less).
The ground terminal is used to obtain the reference potential for neutralization, so if it is not grounded, the discharge amount of the emitter may become unstable and the number of ions generated may decrease. In addition, even when the main unit power is ON without air purge, the discharge of the electrode needle may become
When the female threads for piping type is selected , the pressure inside the nozzle of the main body increases due to the shape of the piping nozzle. When the pressure rises, the ion generation rate decreases.
Because of this, sometimes the maintenance warning turns ON and the NDL LED lights up.
When attaching one of SMC’s various special order nozzles or piping prepared by the customer