Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.
Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.
Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally. 4. Do not use in an environment where there is excessive impact shock.
Since the dimensions of mounting style is the same as pages 6-4-13 to 6-4-20, refer to those pages.
Bore size/Stroke (mm) 6 10, 20, 30, 40, 50 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Adjuster option Nil Without adjuster Functional option AS Extension end adjuster AT Retraction end adjuster Nil Standard A Both ends adjuster P Note) Axial piping CS Extension
Main applications Cotton Stainless steel 304 20 to 100 0.5, 1, 5, 10, 20, 50, 75, 100 0.2 MPa 0.1 MPa Polypropylene Polypropylene 0 to 60 0.5, 1, 5, 10, 20, 50, 75, 100 Glass fiber Stainless steel 316 1, 5, 10, 20 0 to 400 Note) Size for all is 65 x L250. Different lengths are available as a special order up to 750 mm, only for cotton and polypropylene. Elements Part No.
by the following formula: = 10 x mg = 20 x mg mg F = x a 2 x 10 x Workpiece weight 20 x Workpiece weight Even in cases where the coefficient of friction is greater than = 0.2, for reasons of safety, select a gripping force which is at least 10 to 20 times greater than the workpiece weight, as recommended by SMC.
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).
well as the following instructions.
mA D side EVS Note 1) Combining valve VFR31 (single) and release valve spacer makes it possible to use this as an air release valve.
Actuator effective torque S x Ta (S is 10 times or more) ( ) If the mass of the clamp itself in the drawing below is considered in the calculations, it should be regarded as an inertial load. ( ) If the mass of the lever itself in the drawing below is considered in the calculations, it should be regarded as an inertial load.
Equipped with an auto switch (mountable on both sides) Magnet included as standard.
Lightning surge countermeasures should be applied directly to system components as necessary. 2. The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases. 20 mm or more Sheath Piping Connection Caution Insulator Cut the air tubing vertically.
D-F9N(V)/D-F9P(V)/D-F9B(V) Applicable Actuator Series Grommet Series Bore size (mm) Series Bore size (mm) CDU MXS, MXQ 6, 10, 16, 20, 25, 32 6, 8, 12, 16, 20, 25 MXP CDQ2 32, 40, 50, 63, 80, 100 10, 12, 16 * MTS CDQS 12, 16, 20, 25 20, 25, 32, 40 CY1R MY1 16, 20 6, 10, 15, 20 ; MK MXW 8, 12, 16, 20, 25 12, 16 MK2 MXF 8, 12, 16, 20 32, 40, 50, 63 6, 10, 16 *Not available for series CDQP2
Holding of pressure (including vacuum) Since valves are subject to air leakage, they cannot be used for applications such as holding pressure (including vacuum) in a pressure vessel. 6. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve.
Mixed single and double wiring is available as an option.
This seat is available as an option for high temperature applications or specific gas applications, such as N2O or CO2. [PEEK] Polyetheretherketone. This material has excellent heat, fatigue and chemical resistances as thermoplastic resin. This seat is available as an option for the regulators. [Viton] Trademark of DuPont Fluoro-rubber (FKM).
Transportation and installation 2.2 Installation 2.2.1 Environment (1) Do not use or store the product under the following conditions, as these may cause breakage of the product as well as a failure of the product to operate. In an environment where the product will come into direct contact with rain, wind and snow or with a lot of moisture (relative humidity 85% or more).
Allowable horizontal direction load l l m m0 l = 50mm Graph 1 l = 100mm Graph 2 v = 100mm/s or less Graph 6 v = 50mm/s or less Graph 5 300 300 MGF100 MGF100 50 200 200 MGF100 30 40 MGF100 MGF100 100 100 MGF63 30 MGF63 MGF63 20 50 40 50 40 MGF63 Load weight m0 (kg) Load weight m0 (kg) Load weight m (kg) Load weight m (kg) 30 30 20 20 20 MGF40 MGF40 10 10 10 MGF40 MGF40 10 5 4 3 5 4 3 2 2 5