SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-AN-46"

Cutout window AM MGQ View A-A MGG Mounting dimensions MGC (mm) Bore size (mm) Stroke range (mm) MGF A AA AB AG AH AI AJ AK AL AM AN AO AP B I J K M N L 20 25 32 40 50 80 84 75 90 6.6 9 60 75, 100, 125, 150, 200 12 13 105 120 55 110 M6 22 106 25 44 38 25 MGZ 95 89 16 13 120 136 84 100 9 9 65 125 M8 27 120 30 52 70 46 32 105 94 16 13 134 150 92 108 9 9 75 140 M8 32 135 35 60 80 50 32 75, 100

These are installed with double clevis style and double knuckle joint style as standard. 2.4-17 Plate Cylinder Series MU Accessory Dimensions Single Knuckle Joint Double Knuckle Joint (mm) (mm) Applicable pin Model MUl25 MUl32 MUl40 MUl50 MUl63 Z LX RR 8.5 10 11 16 16 LD LU 11 14 15 20 20 LC 16 18 20 28 28 LB 27 31 36 46 46 Z LA 35.5 41 47 62 62 LX RR 8 10 10 16 16 LB 27 31 36 46 46 L 52.5

Can be locked in both directions An equal holding force can be obtained on either reciprocating stroke of the cylinder. Compact lock unit is light weight and saves space Overall length has been reduced by using an independent brake cylinder (15% compared to P/A products).

Note 11) For an actuator with lock, add the power consumption for the lock.

When in the locked state, do not apply a load accompanied by an impact shock, strong vibration or turning force, etc. Use caution, because an external action such as an impacting load, strong vibration or turning force, may damage the locking mechanism or reduce its life. 1. Be certain to connect the rod end to the load with the lock released.

Dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size A B C D E F H K L M N Model Note) Note) Q R Q R Q R S Q R S U 22 (23) 45 (52) 44 43 58 40.5 46.5 99 43 66 83 13.5 28 64 31 6.5 12.5 27 14 12.8 M4 4.5 1/8 VCL21 22 (23) 46 (53) 44 44 58 41.5 46.5 99 44 66 86 18 36 67.5 31 8.5 12.5 27 18 12.8 M4 6 1/4 24 (25) 56.5 (63.5) 46 54.5 60 52 48.5 101 54.5 68 99 22

An application which could have negative effects on people, property, or animals requiring special safety analysis. 4.

An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

If the allowable value is exceeded, an external cushioning mechanism such as an absorber needs to be installed. P. 305 Checking allowable load 5 M = 0.4 x 9.8 x 0.05 + 0.2 x 9.8 x 0.1 = 0.392 [Nm] If the allowable value is exceeded, an external bearing needs to be installed. Check if the load applied to the product is within the allowable range.

Besides, the whole accuracy after mounting on an equipment may be varied depending on the mounting condition and surroundings. As an equipment, calibration should be done by customer.

Cannot be used as an emergency shutdown valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutdown valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.

Also, BBA2 is included when an auto switch alone is shipped.

Also, BBA2 is included when an auto switch alone is shipped.

On the other hand, in ordinary counters, no. 1 is set to 9.98 and no. 2 is set to 10.06, and if no. 1 is ON and no. 2 is OFF, an acceptance decision is made. 2 points of output are used in order to check whether or not the product is within dimension tolerances. In this example, one preset of the CEU5 performs the same function as two presets of an ordinary counter.

On the other hand, in ordinary counters, no. 1 is set to 9.98 and no. 2 is set to 10.06, and if no. 1 is ON and no. 2 is OFF, an acceptance decision is made. 2 points of output are used in order to check whether or not the product is within dimension tolerances. In this example, one preset of the CEU5 performs the same function as two presets of an ordinary counter.

On the other hand, in ordinary counters, no. 1 is set to 9.98 and no. 2 is set to 10.06, and if no. 1 is ON and no. 2 is OFF, an acceptance decision is made. 2 points of output are used in order to check whether or not the product is within dimension tolerances. In this example, one preset of the CEU5 performs the same function as two presets of an ordinary counter.

Please place an order separately. You are requested to connect it to an SI unit and a valve manifold. When using the output block only (valve manifold is unused.), place an order for an end plate (!1 EX9-EA03) separately for connection.

Power consumption is decreased by approx. 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown below. Built-in strainer in the pilot valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side.

For mounting D-A9(V), M9(V), M9W(V), M9A(V) with 32 to 50 to a surface other than the port surface, order an auto switch mounting bracket separately.