SMC Corporation of America
Elite Part Number Search
Search Results "HRL100-AN-40-D1"

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets)

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Cooling Capacity: 400 (CH1: 37 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]

Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: -, Digital Pressure Switch: -, Exhaust Check Valve: -, Exhaust Solenoid Valve: -

M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3

L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420

Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, INSTRUMENTATION, IT200 E/P REGULATOR, D1, IT200 1/4INCH PART, .55000 lb