DC12~24V10% DC12~24V10% DC(+) DC(-) 8 DC12~24V10% DC12~24V10% DC(+) DC(-) 9 ( ) 10 11 -72No.PS-OMU0005CN-C No. / / 5m 12 1015 10 SI (kPaMPa) ( ) SI kPa,MPa 13 14 15 16 FUNC 17 -73No.PS-OMU0005CN-C No. 4m 4m FUNC 18 (Er13) 10 10 () 19 ( ) / () -74No.PS-OMU0005CN-C 80mA 7F.S.(3.5F.S.) 1 1 F.S. 1 -75No.PS-OMU0005CN-C ZSE20B() ZSE20BF() ISE20B() 0.0-101.0 kPa -100.0100.0

Refer to pages 15 through 24 for safety instructions and precautions. Bore size (mm) Standard strokes (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting Caution Mounting and Accessories 1.

Micro mesh element EM810 Hydraulic fluid type (See Table 6-3) Table 6-4 Nominal filtration Symbol Nominal filtration 003 3m 005 5m 010 10m 020 20m 040 40m Note) Refer to the Table 6-7 for the product number of the O-ring for the element. 074 74m 105 105m 149 149m 270 270m 15 / 17 FGX-OM-F001-A [2] Replacement Differential pressure indicator Table 6-5 5.

Refer to 4-3Mounting to duAro flange (P.15). Hexagon socket head cap Positioning pin (510) 1pc. screw (M510) 2 pcs. 4 - 2. Parts description of the air gripper * This drawing shows with protective cover and attachments.

Refer to 4-3Mounting to NEXTAGE (P.15). Hexagon socket head Flange 1pc. Positioning pin (610) 1pc. cap screw (M610) 2 pcs. Hexagon socket head Positioning pin (510) 1pc. cap screw (M510) 2 pcs. 4 - 2.

Trouble Shooting 15 8. How to Replace the Components 16-19 8-1. Diaphragm Assembly Replacement 16 8-2. Valve Guide Assembly and Valve Assembly Replacement 17 8-3. Square Embedded Type Pressure Gauge Replacement 18 8-4. Blanking Plate Assembly Replacement 19 9. Disassembly Drawing 20-21 10.

If the switch output is unnecessary, it is available just like a pressure gauge. page 14 ON Indication color Selects the color to indicate. page 14 ON: Green OFF: Red Response time Sets of a response time prevents chattering in output. page 15 1 s Operation mode Selects the mode to operate the Pressure switch. page 15 Hysteresis mode Hysteresis page 17 0.01 MPa (1 psi) Output type Sets the

20 25 30 15.0 11.5 23.0 10 5 10 15 20 25 30 35 40 45 18.0 10.5 21.0 16 5 10 15 20 25 30 35 40 45 20.0 13.0 26.0 * The above numbers are references for the mounting positions of those auto switches that detect a stroke end.

Maintenance and Inspection 3.1 Inspection -P. 15 3.2 Maintenance -P. 15 3.3 Replacement Parts -P. 15 4. Troubleshooting -P. 16 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

bending radius 80 3.4 13 4.5 6 Series ITV0 Dimensions Single unit for manifolds 56 50 PWR ERR M8 x 1 Cable connection threads 15 15 9 84 86 3.7 Breathing hole Note) (M3 x 0.5) OUTx OUT port (4, 5/32") 8 2 5 18.5 Note) When used under the conditions equivalent to IP65, use the regulator after piping a fitting/tube into a breathing hole.

ON (+)ON 1 OFF ()ON OFF DC(+)DC(-) 2 ON 80 mA 3 () DC(+)DC(-) NPN PNP ( ) 4 OFF () ( ) 5 () DIN 6 -24No.PS-OMF0005CN-E No. 7 / ( 8 () ) -25No.PS-OMF0005CN-E ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 0.010.25 mm 0.030.50 mm (5 m) 30200 kPa 50200 kPa 1.5 20 50 kPa 5 10 L/min (ANR) 100 kPa 8 15 200 kPa 12 22 DC1224 V10 (p-p)10() 15 mA NPN PNP NPN PNP 1 1 1 80 mA 30 V(

Bore size (mm) Bore size (mm) DL DM HR LL MO DB Over 25 to 75st 98 Over 75 to 175st 118 Over 25 to 75st 13.5 Over 75 to 175st 33.5 Over 175st 25st or less 25st or less Over 175st 22 22 9.5 21 15 15 84.5 140 16 0 55.5 32 32 26 23 11.5 25.5 21 19 91 98 118 140 16 0 7 27 49 40 40 24 23 13 27 21 19 50 97 114 134 161 20 0 17 37 64 50 25 25.5 11 25 21 19 63 102 114 134 161 20 0 12 32 59 63

Series RSH 20, 32, 50, 63, 80 How to Order RSH 20 15 D L Z73 Heavy Duty Stopper Cylinder Bore size Number of auto switches 20mm 32mm 50mm 63mm 80mm 20 32 50 63 80 S 2 1 Auto switch Stroke Without auto switch (Cylinder built-in magnet) 15mm 20mm 30mm 40mm 20 32 50/63 80 * Refer to the table below for auto switch model nos.

AD27-A I.D. 2.5 (3/32") at min., Length 5m (200") at max. AD37, 47(N)-A I.D. 4 (3/16") at min., Length 5m (200") at max. AD38, 48(N)-A: I.D. 6.5 (1/4") at min., Length 5m (200") at max. Air Source WARNING Use clean air. Compressed air containing chemicals, organic solvent, synthetic oil or corrosive gas may lead to cause breakage of parts or malfunction.

Document No.AMX-OMZ0106 PRODUCT NAME Antibacterial Filter (5m) Antibacterial Filter (0.1m) Odor Removal Filter Bacteria Removal Filter MODEL / Series / Product Number HF2-BFA HF2-BFB HF2-BFC HF2-BFD Contents 1. Safety Instructions P.2 2. Application P.9 3. Standard specification P.9 4. How to order P.10 5. Replacement parts P.11 6. How to replace the element P.12 7.

AD17-A, AD27-A I.D. 2.5 (3/32") at min., Length 5m (200") at max. AD37, 47(N)-A I.D. 4 (3/16") at min., Length 5m (200") at max. AD38, 48(N)-A: I.D. 6.5 (1/4") at min., Length 5m (200") at max. Air Source WARNING Use clean air. Compressed air containing chemicals, organic solvent, synthetic oil or corrosive gas may lead to cause breakage of parts or malfunction.

AD27-A I.D. 2.5 (3/32") at min., Length 5m (200") at max. AD37, 47(N)-A I.D. 4 (3/16") at min., Length 5m (200") at max. AD38, 48(N)-A: I.D. 6.5 (1/4") at min., Length 5m (200") at max. Air Source WARNING Use clean air. Compressed air containing chemicals, organic solvent, synthetic oil or corrosive gas may lead to cause breakage of parts or malfunction.

With across flat of the guide bolt and tightening torque Width across flats Tightening torque (Nominal) (Nm) 10 1.5 0.27 16 2 0.54 20 2.5 0.95 25 3 2.25 0.2mm Gap gauge 0.2mm Surface plate 15 - 3-4.