0.1 x mcos + msin P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m mv P Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 29) 1 Review of operating conditions Determination of load factor () = Load mass (m) Maximum allowable load (m max) + Static moment (M) Allowable static moment (Mmax)+ Dynamic moment (ME) Allowable dynamic moment (MEmax
Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Port size Weight Valve model Grommet C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT307 VT307V (Vacuum spec. type) VT307E (Continuous duty type) VT307Y (Energy-saving type) VT307W (Energy-saving, Vacuum spec. type) VT307 VT307V (Vacuum spec. type) VT307E
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
ports) [With external pilot] 4-One-touch fitting (P, R ports) Applicable tube O.D.: 8 13.3 (Pitch) P= 10.5 13.3 24 24 16.2 16.2 17 34 34 36.7 B 2 B 2 B 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 PE R 3 R 3 R 3 R 3 P 1 P 1 P 1 P 1 X A 4 A 4 A 4 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 2-One-touch fitting (X, PE ports) Applicable tube O.D.: 6 2n-One-touch fitting (A, B ports) Applicable tube O.D.: 4 6 Applicable
Due to meter-in control, the cylinder moves from A to B regardless of whether it is an initial operation or a normal operation. When it reaches B, the head pressure (PH) rises quickly as indicated by the line from C to D.
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil Standard P Note 1) Axial piping Note 1) The combination of axial piping and both ends adjusters or retraction end adjusters is not available.
Plug Part Number Bore size [mm] Part number Port thread type Quantity 12 (10 x 2) 16 (12 x 2) P-M3 M3 8 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) P-M5 M5 8 P-R1 Rc1/8 8 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) P-N1 NPT1/8 8 P-G1 G1/8 8 P-R2 Rc1/4 8 80 (56 x 2) 100 (71 x 2) P-N2 NPT1/4 8 P-G2 G1/4 8 * 1 set includes 8 pieces.
I) (mm) Width across corners I 85 103 132 H 128 144.5 171.5 FX 73 90 110 FZ 93 114 138 GA 16 24 24 CT 8 10 10 CZ 36 45 45 D 32 40 50 E 64 77 98 FT 20 25 25 O A 221 243.5 299.5 B 93 99 128 CD 20 20 25 L 45 54 56 N 9 11 13 QA 10 12.5 12.5 QB 7 8.5 10 GB 16 24 35 Stroke 30 30 40 Bore size (mm) 50 63 80 14 depth 5 18 depth 6 20 depth 6 P (Piping port) TN NPT 1/8 NPT 1/4 NPT 1/4 R 40 47 54 S
5 CNA CNS Over 100 stroke 20, 25: 50 stroke or less CLS CLQ Extension locking (Type F) Retraction locking (Type B) MLGP N#2 u #6 y @2 u #6 #2 y #5 @2 i i RLQ MLU ML1C D-X Section B-B' Section B-B' 20Section A-A' !6 !6 Section A-A' Data Component Parts Description Material Note No. !7 !8 !
5 @8 B' @9 @0 A' A A' A B !6 !3 #0 40 to 63: Over 100 stroke !6 50 to 100 80, 100: Over 200 stroke Extension locking (Type F) Retraction locking (Type B) !9 @7 #9 #5 i o @5 #5 #9 @7 !9 i @5 o Section B-B' Section B-B' @5 !8@6!7 @5@6!7 !
C D M P R F G H J K L Bracket mounting dimensions Q 25 40 53 70 70 90 95 27 40 56 73 73 50 80 95 120 120 120 120 81.5 122 142 177 177 254 268 25 40 53 70 75 90 95 25.5 38 38 41 39 45 45 M5 X 0.8 AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 30 41 50 50 70 70 27 40 54 54 66 66 22 23 26 25 35 35 5.4 6.5 8.5 8.5 11 11 8.4 8 10.5 10.5 13 13 40 53 70 70 90 90 2.3 2.3 2.3 2.3 3.2 3.2 1/8,
Flow Rate Characteristics Flow rate characteristics 1 2 (P A) 2 3 (A R) Series C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv VG342-X87 26.6 0.04 5.5 28.6 0.03 5.6 Solenoid Specications Safety Limit Switch Specications Electrical entry DIN terminal Rated voltage 24 VDC Manufacturer OMRON Rockwell Automation Electrical wiring M12 connector Contact resistance 25 m or less 50 m or less Allowable voltage
Bore size/Stroke (mm) Data 10 25, 50, 75, 100 16 25, 50, 75, 100, 125, 150, 175, 200 End lock 20 25, 50, 75, 100, 125, 150, 175, 200 25 25, 50, 75, 100, 125, 150, 175, 200 R End lock 32 (25), 50, 75, 100, 125, 150, 175, 200 Nil None Note 1) For (25) stroke, the shock absorber is mounted on a single side of the plate.
(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 16 16 16 12 15 15 44 50 56
Hz*3 kW 2.0/2.5 Temperature stability*4 C CH1: 0.1, CH2: 0.5 Circulating fluid system Rated flow 50/60 Hz*5,*11 L/min CH1: 25/35 (0.5 MPa), CH2: 2/2 (0.5 MPa) Max. flow rate 50/60 Hz*11 L/min 55/65 Max. pump head m 50 Settable pressure range (-P) MPa 0.1 to 0.5 Min. operating flow rate 50/60 Hz*6 L/min CH1: 25/35 (-P: 15), CH2: 1/1 Tank capacity (CH1, 2 total) L Approx. 18 Circulating fluid
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
Plug position Type of actuation B port N.C. A port N.O. (A)4 2(B) (A)4 2(B) Locked position Number of solenoids Single 1 (P) (EA)5 3(EB) 1 (P) (EA)5 3(EB) LOCK 2(B) (A)4 2(B) (A)4 Double PUSH (EA)5 1 (P) 3(EB) (EA)5 1 (P) 3(EB) Caution How to Use Plug Connector When operating the locking type D with a screwdriver, turn it gently using a watchmakers screwdriver.
Improved noise reduction (Stroke end impact noise reduced) Decrease of 19dB or more (compared with CQ2 without cushion) Decrease of 14dB or more (compared with CQ2 with rubber bumper) Features 2 Compact Cylinder with Air Cushion Series RQ 20, 25, 32, 40, 50, 63, 80, 100 How to Order RQ B 32 32 50 50 F9BW With auto switch Without auto switch RDQ B Number of auto switches With auto switch (
MA B D-F9BAL A Proper auto switch mounting positions (mm) 32 to 100 D-Z7, D-Z8, D-Y5 D-Y, D-Y7 D-Y7V, D-Y7WV D-Y7BAL B Bore size (mm) D-Z7 D-Z8 D-Y5 D-Y7 D-Y7W A 10 12 13 16.5 18.5 26.5 B 16.5 18.5 22.5 26 35 44.5 32 40 50 63 80 100 A B D-Y6 D-Y7V D-Y7WV Auto switch mounting heights (mm) SMC D-Y7BAL Bore size (mm) SMC MA 32 40 50 63 80 100 32.5 37 43 51.5 62 74.5 Approx.
-RA Both ends tapped (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc1/8 NPT1/8 NPT1/8 G1/8 7.5 10.5 G1/8 Rc1/8 NPT1/8 NPT1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc1/8 NPT1/8 NPT1/8 G1/8 8 11 G1/8 56.5 39.5 8 11 52 50 41.4 Rc1/8 NPT1