32 40 MGPWA20-150 0.3 0.3 MGPWA -100 32 40 MGPWA20-100 0.2 0.2 MGPWA -50 32 40 MGPWA20-50 0.1 0.1 0 0 0 20 40 60 0 20 40 60 80 100 Load from lateral direction (N) Load from lateral direction (N) MGPWA25 MGPWA50, 63 0.5 0.5 Plate displacement amount (mm) Plate displacement amount (mm) MGJ 50 63 MGPWA -200 0.4 0.4 MGPWA25-200 JMGP 0.3 0.3 50 63 MGPWA -150 MGPWA25-150 0.2 0.2 MGP 50 63 MGPWA
Cylinder stroke (mm) Long stroke (mm) 35, 40, 45, 50, 75, 100 Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30 Action D Double acting 12, 16 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switch.
Rubber bumper is standard equipment for long stroke type. 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Action 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 D Double acting 25 For "Manufacture of Intermediate Strokes", refer to page 7-4-5. Applicable Auto Switch/Refer to page 7-9-1 for further information on auto switches.
J F C X B + Stroke L Z M A + Stroke E T 2-P (port size) I Q Metal connector Made by TAJIMI R04-J8M7.3 15.5 M14 x 1 38 (mm) G A C D E F H J K B I Bore size (mm) 32 40 50 63 Standard stroke 64 131 27 16 45 49.5 M14 x 1.5 4.5 14 90 14 50, 75, 100, 125, 150, 175, 200, 250, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64
150 0.3 MPa 0.3 MP 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 200 200 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 100 100 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80 120 160 200 Gripping point R (mm) Gripping point
350 kPa 150 kPa 350 kPa 150 kPa 350 kPa Flow [L/min] Flow [L/min] Flow [L/min] 150 kPa 750 kPa 750 kPa Number of needle rotations Number of needle rotations Number of needle rotations 14 PF2M7(-L) Series Flow Rate Characteristics at Negative Pressure (Reference Data) When the PF2M series is used with negative pressure (70 to 0 kPa), the measurable range (warranty range of the specifications
CN5 parallel I/O connector CN4 serial I/O connector 150 132 141 CN3 encoder connector CN2 motor power connector CN1 power supply connector 4.6 for body mounting b) DIN rail mounting (LEC6D-) Refer to page 19 for L dimension and part number of DIN rail. (11.5) (81.7) 35 66 1 31 64.2 35 167.3 (When locking DIN rail) 173.2 (When removing DIN rail) 150 132 (91.7) Note) When two or more controllers
Determination of kinetic energy of load (E) E > Es E Es Bore size determination Tentative determination of L type W V 2 E = () 2 1000 Note 2) E > Es Determination of pressure (P) when making intermediate stop P > Ps P Ps Consider made-to-order products, depending on an operating condition. Tentative determination of L type (For intermediate stops, refer to page 1515.)
Wn Weight mn X-axis Xn Y-axis Yn Z-axis Zn Z X Wa 0.88kg 65mm 0mm 5mm 111 Wb 4.35kg 150mm 0mm 42.5mm Y 210 Y Wc 0.795kg 150mm 111mm 42.5mm Wd 1.5kg 150mm 210mm 42.5mm n = a, b, c, d 3 Composite center of gravity calculation m3 = mn = 0.88 + 4.35 + 0.795 + 1.5 = 7.525kg 1 m3 X = x (mn x xn) 1 7.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 1.5 x 150) = 140.1mm 1 m3 Y = x (mn x yn) 1 7.525
a b c d e f g h i j k a ABS INC ABS() / / INC()// b c ) 0.5mm ()/ P.53 8.3 d e f )LEHZ(J)LEHFLEHS 40100% LEHZJ10L, LEHZJ16L 50100% g INP ON P.51 8.3 INP INP ON h 16 - )LEHZ(J)LEHS 550mm/secLEHF10 520mm/sec LEHF203240 530mm/sec /P.50,51 8.3 , i )150% P.52 8.3 j 2 AREA ON INC ABS() k () INP ON() )No.1 5 4 1( ) 17 - (1) a b c d e f g h i j k No.0 0 1<2 INP
3 y o q u e !0 w Parts list Material No. 1 2 3 4 5 6 7 Description Material No.
15 15 70 Open F 24 24 4-M10 X 1.5 through (Thread for mounting attachment) B C D E F G H 110 158 202 J 202 282 366 Model MHL2-32D MHL2-32D1 MHL2-32D2 56 104 148 272 370 454 86 134 178 220 318 402 150 198 242 60 108 152 Note 1) J dimension is at fully closed.
Open F 4 x M8 x 1.25 through (Thread for mounting attachment) (mm) J 146 244 282 A B C D E F G H 66 120 138 Model MHL2-25D MHL2-25D1 MHL2-25D2 70 124 142 88 142 160 48 102 120 100 182 200 150 282 320 196 328 366 38 86 104 Note 1) J dimension is at fully closed.
A B C D E F G H P U Load (kN) Weight (g) Angle Bore size (mm) JA30-10-125 32 70 2.5 0.5 9 8 8 5 24 19.5 49.5 M10 x 1.25 17 JA40-12-125 40 160 4.4 0.75 13 11 11 6 31 20 60 M12 x 1.25 22 5 27 JA50-16-150 50, 63 300 11 1.0 15 13.5 14 7.5 41 22 71.5 M16 x 1.5 JAH50-20-150 80, 100 1080 18 2.0 18 16 32 24 59.5 11.5 28 31 101 M20 x 1.5 CJ1 CJP CJ2 CM2 CG1 MB MB1 CA2 Rod Clevis GKM (ISO 8140)
A B C D E F G H P U Load (kN) Weight (g) Angle Bore size (mm) JA30-10-125 32 70 2.5 0.5 9 8 5 8 24 19.5 49.5 M10 x 1.25 17 JA40-12-125 40 160 4.4 0.75 13 11 6 11 31 20 60 M12 x 1.25 22 5 27 JA50-16-150 50, 63 300 11 1.0 15 13.5 7.5 14 41 22 71.5 M16 x 1.5 JAH50-20-150 80, 100 1080 18 2.0 18 16 32 24 59.5 11.5 28 31 101 M20 x 1.5 CJ1 CJP CJ2 CM2 CG1 Courtesy of Steven Engineering, Inc.
JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200
L L+A Fig. 1 Fig. 2 L 2 1 V E = W ( ) 2 1000 Collision speed V = 1.4 Va Find the kinetic energy E (J) of the load. 1 420 E = 1 ( ) = 0.088 2 1000 V = 1.4 x 300 = 420 Correction factor (reference value) Find the allowable kinetic energy Ea (J).
Nh9 RW L LA0.1 LB PD0.05 PB0.02 E PC0.05 PA0.02 GB GA C 2 x 2 x P H7 depth D 2 x 2 x MM depth J 2 x 2 x NPT 1/4 G Rc Hexagon socket head plug RD B [mm] Bore size B C D E GA GB J L LA LB MM N P Rubber cover Metal cover 50 92 48 12 13.7 95 166 12 376.6 155.5 78.4 78.4 M8 x 1.25 19 8 63 110 54 15 16.6 99 171.5 12 391.6 161 78 78.4 M10 x 1.5 22 10 Bore size PA PB PC PD R RA RB RC RD RR W XB XC
Trace the arrow mark from the intersection D to obtain the intersection E. 4. The intersection E is the dew point under pressure 102 psi (0.7 MPa) with an ambient temperature 86F (30C) and a relative humidity 60%. The value for E is 144F (62C). 5. Trace the intersection E upward, and trace from the intersection D leftward to obtain the intersection C. 6.
Component Parts Replacement Parts No. u i Description Description Sub-plate Pilot valve No. q w e r t y Note Aluminum die-casted Part no.