SMC Corporation of America
Elite Part Number Search
Search Results "CDNGFA25-400-D-M9BL-C"

Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 75mm, Rod Boot: None

Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa):

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa):

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Air cushion, Operating Pressure(MPa

Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Air Cushion, Bore Size: 25mm, Port Thread: Rc, Stroke: 25mm, Rod Boot: None, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Air Cushion, Bore Size: 25mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: None, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Mounting: Front Flange, Cushion: Non-lube Air Cushion, Bore Size: 25mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -

(Parameter initial configuration Set the recommended parameter value Operation start) *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 26 - Recommended Parameter Values [LEY] LEY25/ LEY25D/ LEY32/ LEY32D/ LEYG25 LEYG25D LEYG32 LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.

VCHR 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVX c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.

7 5 A6063 2 1 6 SUS304 3 2 9 2 SUS304 SUS304 11 XL-OMY0001 5-2 C E E E KF K Fd Fn C D H B A G A mm A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMY0001 6. 200 []1 1.5 1 200 FKM 110Pa

Z (Example) F9BZ D-F9BA is available only as "L". Auto switches marked with a "" symbol are produced upon receipt of order. Note 1) Take note of hysteresis with 2 color indication type switches. Note 2) Refer to pages 53 through 65 for detailed auto switch specifications. Cylinder Bore Size MHS 2 D 50 32 to 63 Y59A Number of auto switches Nil S 2 pcs. 1 pc.

Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 9 Direct Operated Precision Regulator/Modular Style Series ARP20/30/40 Dimensions 2 x P1 Port size A Pressure gauge (Option) Q C OUT IN K V P2 Pressure gauge port size B R Bleed port F S D U N Bracket (Option) J M T Panel fitting dimension Y The dimensions for special applications (not including

AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B 8B C 2B, 3B, 4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 4B, 6B 870 M20 x l500 AMF1000 14-20-48

D-M9/D-A9 D-M9 D-M9W D-M9AVL D-M9V D-M9WV D-M9AL D-A9 D-A9V A B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) ( )D-A96 -15 D-P3DW D-P3DW A B Hs Ht 50 14.5 6.5 41 35 63 16.5 10 47 44 80 30.5 17 55 54 D-P3DW BQ6-032S -16 18 - 7-3. 7-3-1.D-M9D-A9 (-) -17 5~6mm D-A9(V)

This is a legacy product, and replaced byMDWBF63-150-M9BL MNB CYLINDER WITH FINELOCK . 63MM MNB DBL-ACT AUTO-SW. ACTUATOR. 63MM MNB DBL-ACT AUTO-SW. 13.62456 lb. PE .

This is a legacy product, and replaced byMXH10-15Z-M9BL, CYL, COMPACT SLIDE TABLE *LQA, ACTUATOR, 10MM MXU DBL-ACT AUTO-SW, .50540 lb