SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KB10-125Z-M9P-B"

B When LECP1, LECP6 or LECPMJ is used.

CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.

30.5 31.5 18.5 19.5 Grommet (Perpendicular) Reed switch Model Model 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 D-A90V 5 25.5 26.5 13.5 14.5 A B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.

With lock/226) 28 (64) Stroke 39 (4) 21 Motor cable (6) 70 58 47 6.7 17.5 Vacuum port Rc1/8 Note 3) 35 Encoder cable (7) Lock cable (4.5) Motor option B: With lock 8H9 ( ) depth 6 +0.036 0 13 n x 6.8 B 30 8H9 ( ) depth 6 +0.036 0 140 200 E C x 200 (= D) 25 Note 1) Please consult with SMC for adjusting the Z-phase detecting position at the stroke end of the end side.

A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

(between case and cable) Ambient temperature -10 to 60 C Enclosure IEC 60529 criteria IP67, JISC0920 watertight construction Standard CE/UKCA marked -24No.D-S-OMJ0004-G Dimensions D-M9B(W/E)/D-M9N(W/E)/D-M9P(W/E) D-M9B(W/E)V/D-M9N(W/E)V/D-M9P(W/E)V -25No.D-S-OMJ0004-G Pre-wired connector A B D-M9### PC D-M9###DPC -26No.D-S-OMJ0004-G Revision history A: Standardize each contents for series

Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

Note) A B A B Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8, F9 type 2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) For other model nos. 3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type.

Refer to page 378 for minimum stroke with auto switch. 32 is for B-series rod size only. CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359.

C B A stroke A C 3) 2nd stage: B-A stroke operation Following the 1st stage, when the air pressure is supplied from the C port, the rod operates the B-A stroke. B B-A stroke B A C 4) Cylinder retraction When the air pressure is supplied from the B port, the rod retracts completely. B stroke A stroke A stroke or B stroke operation can be made individually.

B Stroke B-A Stroke B operation 1) Initial state (0 stroke position) Stroke B Stroke A C 2) Operation When the air pressure is supplied from the C port, the rod operates the stroke B. B B A Stroke B A C Stroke B Stroke A Double output is possible.

MRQ L r b a = K + mL2 K: The moment of inertia around the center of gravity of the load K = m r2 12 a2 + b2 = m In case of 4. Round plate 2 4. Round plate (Including column) Position of rotational axis: Passing through the center axis 9. Gear transmission (A) (B) No. of teeth = a 1. Find the moment of inertia B for the rotation of shaft (B). 2.

Hs Auto switch 12 D-B5/B6 15 22.5 A B 33 410 Auto Switch Mounting CHA Series Auto Switch Proper Mounting Positions (mm) D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-G39/K39D-A9/A9V D-A5/A6 D-A59W D-B5/B64 D-B59W D-A3/A44 Bore size (mm) CHQ A B A B A B A B A B A B A B A B A B A B A B CHK 40 20.5 21.5 17 18 22 23 12.5 13.5 10.5

D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F Auto switch model D-A9 D-A9V D-A59W D-F5NTL A A A A A A B B B A B B B B Bore size 125 140 160 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 9 7 14.5 13 3 9.5 8 6 13.5 6.5 12 2 8.5 5.5 Provided as guidelines for auto switch proper mounting position (detection at stroke end).

bolt A Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B Adjustment amount by adjustment bolt B 90 Rotation 90 Rotation 90 Rotation 278 Rotary Table/Rack & Pinion Style Series MSQ Construction CRB2 CRBU2 CRB1 MSU CRJ o i t !

CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]

C A B C A B C A B C A B C A B C LEY40 1100 Work load [kg] 1 1.5 3 2.5 5 10 4.5 9 18 7 14 28 1 1.5 3 1.2 2.5 5 Lead 4: LEY40C 800 900 1000 Pushing force 85% 65% 85% 65% 95% 95% Lead 8: LEY40B Lead 16: LEY40A 10 20 30 40 50 60 70 80 90 0 100 200 300 400 500 600 700 Force [N] Non-rotating Accuracy of Rod Size Non-rotating accuracy q 16 1.1 25 0.8 32 0.7 40 + Max. 65% Set value of pushing force

Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Non-rotating rod type, Bore sizes: 10 and

Solid State Auto Switch: D-M9B, D-M9N, D-M9P, D-M9BW, D-M9NW, D-M9PW Stroke B Stroke E Model A 40 50 150 10 20 30 40 75 100 125 150 10 20 30 125 75 100 50 B MXS6 -0.4 -0.4 -0.4 11.6 17.5 9.6 9.6 9.6 21.6 27.6 10 MXS8 4.9 -0.1 0.9 8.9 16.9 41.9 14.9 9.9 10.9 18.9 51.9 26.9 11.6 MXS12 32.4 22.4 12.4 14.4 45.4 74.4 24.4 22.4 12.4 2.4 4.4 14.4 35.4 64.4 15.6 MXS16 32.7 22.7 12.7 12.7 42.7

Next, B is entered to find A the inertial moment for the rotation of shaft (A) as 5 b a A = ( ) 2 B Number of teeth = b Kinetic Energy/Rotation Time Even in cases where the torque required for rotation of the load is small, damage to internal parts may result from the inertial force of the load.