Standard strokes Bore size (mm) Standard stroke (mm) Long stroke (mm) 75, 100, 125, 150, 175 350, 400, 450, 500, 600 40, 50, 63 200, 250, 300 700, 800, 900, 1000 Intermediate strokes and strokes of 75mm or less can also be manufactured.
0.016 0.043 +0.043 0 0.025 0.064 40 40 40 36 M20 x 1.5 30 27 22.4 9 19 60 255 M16 x 1.5 25 22 18 7 14 55 250 0.025 0.064 0.020 0.053 +0.052 0 50 50 46 40 M24 x 1.5 35 32 28 11 24 65 285 M20 x 1.5 30 27 22.4 9 19 60 280 63 63 55 46 M30 x 1.5 45 42 35.5 13 30 80 337.5 M24 x 1.5 35 32 28 11 24 70 327.5 0.030 0.076 0.025 0.064 +0.062 0 80 80 65 55 M39 x 1.5 60 57 45 15 41 95 382.5 M30 x 1.5
, 300, 350, 400 450, 500 15 1000 750 25 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800 2000 1500 Note) Intermediate strokes can be arranged in 1mm increments.
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
Note 4) When the stroke is 25 mm, the maximum speed will be 250 mm/sec. Note 5) Set to the pushing force when pushing. Note 6) The speed and force may change depending on the cable length, load and mounting conditions. Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m.
30 300 35 350 LMV20/Without air blow circuit T0806 (8 x 6) Applicable tubing Symbol Length T0425 (4 x 2.5) Applicable tubing Air adjusting needle for mist T0604 (6 x 4) Applicable tubing Oil adjusting needle Mixing valve (LMV20-) LMV201 L 46 (24) Double pipe nozzle AIR OIL D C B 12 E A 24 9.5 2 3 57(Max.) 12.5 AIR SMC 27.5 4 10 40 23.5 OIL L Dimension (mm) 20 200 25 250 30 300 35 350 7.5
Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1. Keep within the specified ambient temperature and humidity range.
x V x C x iT it m x C x (T0 Tt) it Q = = 1 x 250 x 4.186 x 103 x 12 900 = = 13953 [J/s] 14.0 [kW] m x C x (T0 Tt) it x 860 x V x 60 x C x iT it x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 14.0 [kW] x 1.2 = 1 x 250 x 60 x 1.0 x 103 x 12 15 x 860 16.8 [kW] = Thermo-chiller Q x t: Heat capacity [kJ] 13953 [W] = 14.0 [kW] Water bath 20C Cooling capacity = Considering
Stations n L1 L2 3 74 56 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 15 266 248 16 282 264 17 298 280 18 314 296 11 202 184 12 218 200 13 234 216 14 250 232 19 330 312 2 stations 58 40 20 stations 346 328 531 Manifold specifications 10-SYJ5000 Type 41: Side ported / 10-SS5YJ5-41Stations -M5 [ ]: AC Grommet (G) Approx. 300 (Lead wire length) L1 L2 4.5 Manual override
Control equipment connected to the barrier must not use or generate more than 250 V. 2. Installation should be in accordance with Canadian Electrical Code or ANSI/ISA RP12.6 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code or ANSI/NFPA 70. 3.
14 Inlet pressure 0.3 MPa Inlet pressure 0.3 MPa Inlet pressure 0.3 MPa 12 10 Inlet pressure 0.5 MPa 6 10 Inlet pressure 0.5 MPa Inlet pressure 0.5 MPa 8 Pressure drop [kPa] Pressure drop [kPa] Pressure drop [kPa] Max. flow capacity line 8 Max. flow capacity line Max. flow capacity line 6 4 6 4 4 2 2 2 Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa 0 150 0 50 0 300 250
Please contact SMC. 2) Tested with Helium gas inlet pressure 250 psig (1.7 MPa). 3) Mass, including individual boxed weight, may vary depending on connections or options. 4) Optional lever color available. Please contact SMC. 5) Handle must be pulled to turn open from closed. 6) Refer to the specification for options.
Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500
, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 Available Available (40 to 63) 11-/22-CG120 11-/22-CG125 11-/22-CG132 11-/22-CG140 11-/22-CG150 11-/22-CG163 11-/22-CG180 11-/22-CG1100 Non-lube Double acting, Available 20 25 32 40 50 63 80 100 single rod 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note) Consult SMC for long stroke.
Note3) For 16, 20 and 25, strokes up to 300, and for 32, strokes up to 250 are available as made-to-order. (-XB11) Built-in Magnet Cylinder Model End lock If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
R1), 3(R2) port) 3-3-25 Series VZ3000 Type 20 Manifold VV5Z3-20Station 1 Grommet (G), (H) (4(A), 2(B) port) (Pitch) (Mounting hole) 6-Rc 1/8 (1(P), 3/5(R) port) G: 300 mm H: 600 mm Manual override (Non-locking) (PE port) (Lead wire length) (mm) Stations 2 3 58 40 74 56 20 346 328 L1 L2 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 11 202 184 12 218 200 13 234 216 14 250
Vibration resistance allows for normal operation up to 30 m/s2 (45 to 250 Hz), but continuous vibration may cause a decline in durability. Arrange piping to avoid excessive vibrations or shocks. High temperature type (Model/XLA, XLC, XLD, XLF, XLG; Temperature specifications/H0, H2, H3) 1.
Bernoulli Type Cyclone Type High lift Vibration reducing High lifting force: Max. 44 N* Amplitude of the workpiece during gripping: 0.01 mm*or less * Solar battery silicon cell (l125 mm, t = 250 m) * In SMC conditions (How to calculate: Page 730) Non-contact gripper * Outer body diameter: 100 Lifting force (Supply pressure: 0.4 MPa) Workpiece (Solar battery silicon cell) Amplitude 50 40