WH 32 (E1) D 21 19 17.3 41.4 6.4 7/16-20 126.4 I 40 19 16.6 17.3 41.4 6.4 7/16-20 134.4 B2 BZ MM AL A 50 22.4 19.8 18.8 52.6 7.9 1/2-20 161.6 Plug bolt (4 pcs. included) K KA 8-J 63 22.4 19.8 18.8 52.6 7.9 1/2-20 161.6 (F1) C 0.1 80 S + Stroke ZZ + Stroke H 25.4 22.9 23.9 63.5 9.7 5/8-18 193.5 NA 100 31.8 29.3 27.8 69.9 10.7 3/4-16 200.9 80 and 100mm-X165US are a future release.

Slave unit 03 Connector with end resistance Master unit Twisted pair with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground Connect the shielding wire to the SD terminal.

Slave unit 03 Connector with end resistance Master unit Twisted pair with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground Connect the shielding wire to the SD terminal.

X, PE port F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins) Elbow fitting (Downward) B With external pilot spec. X, PE port PCW type There is no need to enter anything when the SUP/EXH block mounting position M is selected. Pilot spec.

A Symbol Flow adjustment valve Stop valve Nil 61.9 S 61.9 Nil P 95.9 W 95.9 0.5 to 4 L/min 3/8 (symbol 04) (symbol 03) Nil 72.9 S 72.9 Yes P 106.9 Remote sensor/ W 106.9 Integrated display type Nil 65.9 S 65.9 Nil P 99.9 3/8 W 99.9 (symbol 03) 2 to 16 L/min 1/2 (symbol 20) Nil 76.9 (symbol 04) S 76.9 Yes P 110.9 W 110.9 B: Total length of the supply unit (mm) Unit construction

0.29 J 0.46 J 0.84 J Allowable kinetic energy Female rod end 0.11 J 0.18 J 0.29 J 0.52 J Operate the cylinder within the allowable kinetic energy.

4-G C 1.5 B D L E 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Port size Bracket part no.

(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.

Check the setting for the station address of the host PC or PLC...etc, and reset the setting of the rotary switches, S1 and S2 to change the address to the proper value between 03 and EF. Check the rotary switches, S1 and S2, to see if the station address is within the allowable range from 03 to EF. The station address is out of the allowable setting range.

LV 4-G C 1.5 PA B D E L 4-H Valve mounting hole F Bracket mounting dimensions A B C D E F G H J L Bracket part no.

4-G C 1.5 B D L E 4-H Valve mounting hole F Bracket mounting dimensions A B C D E F G H J L Bracket part no.

LAT LZ USB cable (2.5 m) Cable for safety function device (3 m) LEC JZ CVSAF LC3F2 LEC JZ CVUSB * JZSP-CVS06-02-E manufactured by YASKAWA CONTROLS CO., LTD. * JZSP-CVH03-03-E manufactured by YASKAWA CONTROLS CO., LTD. Cable for connecting PC and driver when using the setup software (SigmaWin+TM). Do not use any cable other than this cable.

For lock unit with bellows, please add -J to the part number suffix. Ex.) MWB50-UA-J Lock unit replacement 1) To release the lock state, screw-in the lock release Check that the piston rod operates smoothly by hand while maintaining the lock release state. bolt to the body cap end or pressurize the lock release port with 0.3MPa or more.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing August, 2003 D-YGA P-120 (YG) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing September, 2003 D-DN P-120 (DN) Printed in Japan.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing May, 2001 D-SMC.L.A. P-80 (YG) All specifications in this catalog are subject to change without notice. Printed in Japan. This catalog is printed on recycled paper with concern for the global envionment.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing January, 2001 D-SMC.L.A.

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case

Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket