Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
2 position double: VQ525 3 position closed center: VQ535 3 position exhaust center: VQ545 3 position pressure center: VQ555 3 position double check: VQ565 0 1 0 1 0 1 0 1 G H G H G H G H 194.5 (200) 121.3 53 73.2 (78.7) Indicator light 213 121.3 91.5 13.5 (Port B) 59.5 53 (Port A)17.5 13.5 (Port B) 59.5 (Port A) 17.5 Indicator light SMC 2 4 2 4 SMC A B A B 53 40 66 162 50 41 37 31.5 18 53
2 position double: VQ525 3 position closed center: VQ535 3 position exhaust center: VQ545 3 position pressure center: VQ555 3 position double check: VQ565 0 1 0 1 0 1 0 1 G H G H G H G H 194.5 (200) 121.3 53 73.2 (78.7) Indicator light 213 121.3 91.5 13.5 (Port B) 59.5 53 (Port A)17.5 13.5 (Port B) 59.5 (Port A) 17.5 Indicator light SMC 2 4 2 4 SMC A B A B 53 40 66 162 50 41 37 31.5 18 53
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZM With valve 07 5 K E15 LZ 1 S A H L Supply valve, Release valve ZM 07 H 2 E15 L Without valve Vacuum switch electrical entry Nozzle diameter Nil L Grommet type, with 0.6 m lead wire Grommet type, with 3 m lead wire C Connector type, with 0.6 m lead
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
y Return spring Stainless steel CAC406 u Body Dimensions: Bracket A J 4-G C 1.5 B D E L 4-H Valve mounting hole F Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D E F G H J L Valve model Bracket part no.
bracket) are included with the above parts. 3 Direct Operated 2 Port for Heated Water Series VCB Dimensions Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port
Number of needle rotations Dimensions D3 Applicable tubing O.D. d D1 L3 A L4 M T H (Width across flats) L2 L1 Metric Size/Inch Size [mm] Model d T H D1 D3 L1 L2 L3 L41 A2 M Weight [g] Unlocked Locked Unlocked Locked AS121F-M3-02A-X790 2 11.9 5 AS121F-M3-23A-X790 3.2 7.2 17.2 21.7 5.8 15.8 20.3 16.9 13.3 AS121F-M3-04A-X790 4 8.2 AS121F-M3-06A-X790 6 10.4 18.6 23.1 16.5 6 AS121F-M3-01A-X790
W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option Digital pressure switch (Electrical entry: Wiring top entry) Digital pressure switch (Electrical entry: Wiring bottom entry) Square embedded type pressure gauge Option Round type pressure gauge J J J J H Dimensions Center of piping H H Center of piping H Center of piping Center of piping Standard
0.01mm 700.00mm 7016 00011170h 00 01 11 70 h 64h 00h RWwn+1 15bit 8bit 7bit 0bit 01h 00h RWwn+2 15bi 8bit 7bit 0bit 70h 11h RWwn+3 15bi 8bit 7bit 0bit 39 - 12.2 IF ( ) IF ID ID=1 bit 7 6 5 4 3 2 1 0 I_Address RWrn+8 bit F E D C B A 9 8 I_Address RWrn+8 (1) (LEC)1(ON)0(OFF) (2) (LEC)0(OFF)(LEC)1(ON) (3) 1 (LEC)1(ON)0(OFF) (4) (LEC)1(ON)0(OFF) 40 - 12.3 (IO ) No Rx00 (L) Rx01 (H) Rx02
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMX1011 Data
Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65. However, if the panel mount adapter is hold enough with screw and the instrument is not seated correctly, water might enter.
ON UP ON/OFF SET DOWN ON/OFF -12No.PF-OMN0011CN-C F F.S.(1~5V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] A 1-5V 1-5V 4-20mA (Hysteresis) ON OFF 90% () Ka (copy function) () 10 L/min 10 L Sa ON OFF ON OFF , , 2 5 10 L/min 5 ,10550 L ON-OFF 1 L/min ,10 11 12 1 L/min -13No.PF-OMN0011CN-C SI SI Ta ON-OFF Na ON 0 Ha -14No.PF-OMN0011CN-C M38 L(2 ) (ZS-26-B) (ZS-26-01) ZS-26-01 1
1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4
Dimensions (Hexagon width across flats) Dimensions Min L1 H Screw D D Model Max 20.5 20.5 30 34.2 37 49 ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 8 8 12(12.7) 17(17.5) 19 24(23.8) 23.3 23.3 35 39.2 42 54 10 10 15 20 25 30 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Screw D Note) (in parentheses) are the dimensions of NPT screw specifications. Caution Be sure to read before handling.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-l02 : E4-l03 : E4-l04 1 4 3 8 1 2 1 4 1 2 : E6-l06 : E6-l10 3 4 1 : E5-l04 : E5-l06 : E3-l02 : E3-l03 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) l in the gauge part number (e.g.