Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 3.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 5.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 6.50000 lb
AIR MANAGEMENT SYSTEM, AIR MANAGEMENT SYSTEM, Q22, 1.60000 lb
AIR MANAGEMENT SYSTEM, AIR MANAGEMENT SYSTEM, Q22, 2.20000 lb
AMS (Electro-Pneumatic Regulator type), AIR MANAGEMENT SYSTEM, Q22, 2.50000 lb
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X102
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 03 (3/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X102 (Hub and Relief Valve only)
EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-26: 2007 EN 60079-31: 2009 EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-15: 2010 EN 60079-31: 2009 II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA Output: Ui 30 V, Ii 152 mA II 3 G Ex ic IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA, Pmax = device limits itself, Ci 22 nF, Li 53 H.
(PFH) PFH = 6.4 10-9 [1/h] Number of on/off times of STO 1,000,000 times LVD: EN 61800-5-1 CE marking EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061 Note 1.
(PFH) PFH = 6.4 10-9 [1/h] Number of on/off times of STO 1,000,000 times LVD: EN 61800-5-1 CE marking EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061 Note 1.
(PFH) PFH = 6.4 10-9 [1/h] Number of on/off times of STO 1,000,000 times LVD: EN 61800-5-1 CE marking EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061 Note.
EU2006/66/EC20[] Hg:(0.0005%), Cd:(0.002%), Pb:(0.004%) / 4 4.1 (IEC/EN 61800-5-2 ) STO(IEC/EN 61800-5-2: 2007 4.2.2.2 STO) LECSS2-TSTOSTO 4.2 4 4.2.1 LECSS2-T () 4.1.2 LECSS2-T ISO/EN ISO 13849-1 3 PL dIEC/EN 62061 SIL CL 2IEC/EN 61800-5-2 SIL 2 (STO) IEC/EN 61800-5-1IEC/EN 61800-3IEC/EN 60204-1 LECSS2-TMR-J3-D05()PLCs 4.1.3 LECSS2-T() 15 (1) (a) 75/60[AWG] 75/60 [AWG](1) L11L21
DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For details, refer to page 482. For connector cable of M8 connector, refer to page 490.
61131-2, EN 61131-6 Machinery directive Yes, 2006/42/EC, EN 62061, EN ISO 13849 RoHS 2011/65/EU, EN50581: 2012 TUV Certification Yes, IEC 61508, EN 62061, EN ISO 13849 PROFINET & PROFIsafe Yes UL/cUL Yes,E209424 28 No.EX##-OMY0011-A 6.
60068-2-27/29 Operating environment No corrosive gas Certifications EMC directive Yes, 2014/30/EU, IEC61326-3-1 Machinery directive Yes, 2006/42/EC, EN 62061, EN ISO 13849 TUV Certification Yes, EN 61508, EN 62061, EN ISO 13849 PROFINET & PROFIsafe Yes UL Yes, for used materials (UL508) 21 No.EX##-OMY0004 5.
Battery (Cell) : LEC-JZ-CVBAT Lithium content : 0.31(g) 11 Harmonized Standards European Directives Model European Directives Harmonized Standards Machinery Directive 2006/42/EC EN ISO13849-1: 2008 EN 954-1 LECY-V (SGDV) EN 55011 /A2 group 1, class A EN 61000-6-2 EN 61800-3 DRIVER EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC EN 50178 EN 61800-5-1 EN 55011 /A2 group 1, class
Battery (Cell) : LEC-JZ-CVBAT Lithium content : 0.31(g) 11 Harmonized Standards European Directives Model European Directives Harmonized Standards Machinery Directive 2006/42/EC EN ISO13849-1: 2008 EN 954-1 LECY-V (SGDV) EN 55011 /A2 group 1, class A EN 61000-6-2 EN 61800-3 DRIVER EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC EN 50178 EN 61800-5-1 EN 55011 /A2 group 1, class