Max acceleration/deceleration [mm/s2] Positioning repeatability [mm] 0.01 Lost motion[mm] Note3) 0.05 Lead [mm] 20 12 6 24 16 8 30 20 10 Impact/Vibration resistance [m/s2] Note4) 50/20 Actuation type Ball screw (LEKFS)Ball screw + Belt (LEKFSR/L) Guide type Linear guide Operating temperature [] 5 to 40 Operating humidity [%RH] 90 or less(No condensation) Motor output [W]/size [mm] 100W/40
Impact/Vibration resistance (m/s2) Note) 150/50 Enclosure Dustproof Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF.
Standard Specifications VQ7 Compact yet provides a high flow capacity 1/4: C: 3.4 dm3/(sbar) Low power consumption: 1.8 W DC Fluid Air/Inert gas Maximum operating pressure Minimum operating pressure 1.0 MPa 0.1 MPa EVS Valve specifications Electricity specifications Ambient and fluid temperature 1.5 MPa Proof pressure VFN 10 to 60C (1) Non-lube (2) Non-locking push type (Flush) 150/50 m/s2
without control unit and bracket mounted, Others 30 m/s2, whichever is smaller for 2 hours in X, Y, Z direction each (De-energized) Vibration resistance Without control unit and bracket mounted: 980 m/s2, Others: 150 m/s2 in X, Y and Z direction, 3 times each (De-energized) Nil: Rc 1/8, N type: NPT 1/8, F type: G 1/8 4-core, oil resistant, cable (0.64 mm2) with M12, 4-pin pre-wired connector
Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMCs website (http://www.smcworld.com/). 10 to 150 Hz with a 0.035 mm amplitude or 4.9 m/s2 in each X, Y, Z direction for 2 hrs (De-energized) 147 m/s2 in each X, Y, Z direction, 3 times (De-energized) Standard CE marking, UL (CSA) Communication connector
Compatible Compatible Compatible ORIG direction Set in units of 1/s Speed during return to origin position Set in units of 1 mm/s ORIG speed No setting required Set in units of 1/s2 Acceleration during return to origin position Set in units of 1 mm/s ORIG ACC Continuous operation at the set speed can be tested while the switch is being pressed.
Address Description of bytes tion unit range Input Mode D0410 4 Target position [m] Note 1) 1 Note 1) No D0412 2 Positioning time [0.01s] 1 0 to 6000 No D0413 2 Speed [mm/s] 1 0 to 400 No D0414 2 Acceleration [mm/s2] 1 0 to 60 No D0415 2 Deceleration [mm/s2] 1 0 to 60 No 1 to 20, Pushing speed [mm/s] D0416 2 1 No 32768 to Note2) 32788 Thrust setting value Note 3) More than D0417 2 1 Yes [
External terminals (including the FE terminal) and enclosure screws Insulation resistance 10 M or more 500 VDC External terminals (including the FE terminal) and enclosure screws EN61131-2 compliant 5f<8.4 Hz 3.5 mm Vibration resistance 8.4f<150 Hz 9.8 m/s2 Impact resistance EN61131-2 compliant, 147 m/s2, 11 ms Mounting Through hole for M4 screw (2 pcs.)
Maximum acceleration: 2000mm/s2 Positioning distance (mm) 1 1000 500 100 10 10 0.5 100.5 50.5 10.5 1.5 100 0.5 10.5 5.5 1.5 0.6 Speed (mm/s) 500 0.5 2.7 1.7 0.9 0.6 1000 0.5 1.9 1.4 0.9 0.6 A B C D Values will vary slightly depending on the operating conditions.
When selecting the overhang, refer to "Calculation of Guide Load Factor" or the Electric Actuator Selection Software for confirmation, http://www.smcworld.com Dynamic Allowable Moment Acceleration/Deceleration 1000 mm/s2 3000 mm/s2 5000 mm/s2 Orientation Load overhanging direction m : Work load [kg] Me: Dynamic allowable moment [Nm] L : Overhang to the work load center of gravity [mm] Model
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Acceleration Stroke Cushion seal RHC MK(2) 15 m/s2 5 m/s2 (REB) (REA) RS Q G High precision guide type: REAHT (Double axis) High precision guide type: REBHT (Double axis) RS H A REB REA RZQ High precision guide type: REAH (Single axis) High precision
(Unit: mm/s2) to 10 Deceleration 5000 5000 Sets the deceleration to reach the moving speed. (Unit: mm/s2) to 10 Selects the pushing operation or the positioning operation from the set value. For the pushing operation, this value specifies the force to be generated as a percentage of the maximum pushing force. (Unit: %) The maximum pushing force depends on the electric actuator.
ZB-OM00201-B Specifications General Specifications Ambient -5 to 50oC (No condensation) temperature range Fluid Air, inert gas Vibration 30m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 1) 20m/s2 (With switch) Impact 150m/s2 (Without pressures sensor/vacuum pressure switch, With pressure sensor) resistance Note 2) 100m/s2 (With switch) Note 1)
(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.
Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Ambient & Fluid Temperature -10 ~ 50C A Clean Room version is available to specified Lubrication Not Required order please contact your local SMC Sales Office Manual Override Non-Locking Push Type Shock Resistance/Vibration Resistance 150 / 30m/s2 for further information. Mounting Orientation Free The VQD1000 is used either on a Single SubEnclosure Dust Proof base or Manifold Mounted.
Mount switches in locations where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Do not drop, bump, or apply excessive impact (PSE540: 980 m/s2, PSE560: 500 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is 50 N. Applying a greater pulling force to it can cause malfunction.
specifications Coil specifications Seal material NBR, FKM, EPDM, PTFE Ambient temperature (C) 20 to 60 1 to 60 (No freezing) Fluid temperature (C) VC Dusttight/low jetproof (equivalent to IP65) Enclosure VDW Environment Location without corrosive or explosive gases (3) Valve leakage (cm3/min) 0 (With water pressure) VQ Mounting orientation Unrestricted (4) Vibration/Impact resistance (m/s2
T1 T2 T3 T4 L 0.5 V (T1 + T3) V T2 = L : Stroke [mm] (Operating condition) V : Speed [mm/s] (Operating condition) a1: Acceleration [mm/s2] (Operating condition) a2: Deceleration [mm/s2] (Operating condition) 500 0.5 300 (0.1 + 0.1) 300 T1 = V/a1 [s] T3 = V/a2 [s] = P T2: Constant speed time can be found from the following equation. = 1.57 [s] T4 = 0.3 [s] T2 = [s] L 0.5 V (T1