G D G 24 V 0 V 24 V 0 V D G D G 24 V 0 V Power supply { 24 V 0 V Power supply { 24 V 0 V Power supply { Transmission line Transmission line G D 0 V 24 V G D 0 V 24 V G D 0 V 24 V G D 0 V 24 V Black White Brown Blue Crimp connector SL-J1A Main transmission line Transmission line 24 V 0 V Power supply { 24 V 0 V Power supply { 24 V 0 V D G D G 24 V 0 V 24 V 0 V D G D G 24 V 0 V The above is
32.3 (A, B port) 1/8 0.8 1.6 16.2 (20) 15 EA P EB 28.1 [32] For manifold gasket positioning 22.2 die-cast hole (P, EA, EB port) 1/8 27.2 32.5 20.5 23 32.3 L plug connector: L SY5120-L(-F ) 1 2 C4, N3 C6, N7 C8, N9 M plug connector: M SY5120-M(-F ) DIN terminal (D): C4, N3 C6, N7 C8, N9 SY5120-W0(-F ) 1 2 M8 connector (W0): C4, N3 C6, N7 C8, N9 1 2 C4, N3 C6, N7 C8, N9 1 2 SY5120-D(-F ) 60.9
9 Station D side 50 29.5 Cover diameter 1.4 75.5 300 3.8 Cross sectional area 0.2mm2 (Lead wire length) 64 62 11.5 29.5 34 The broken line indicate DIN rail mounted type [-D].
Valve model Port size VCS21 VCS20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCS30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCS30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCS30-12-04 VCS41 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCS Direct Operated
Valve model Port size VCS21 VCS20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCS30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCS30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCS30-12-04 VCS41 1/2 48 56 36 44 23 23 6 5.5 7 23 VCS40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCS Direct Operated
A L D VQZ D KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 VQD Color: White VZS VFS EXH port silencer VS 63 Silencer is installed in the EXH port.
Dimensions Applicable tubing O.D. d Inch Size Metric Size L3 (1) Model L3 Model Weight (g) Weight (g) M1 d M1 D1 D2 L2 L1 D2 D1 L2 L1 d Min. 24.9 25.5 Min. 24.9 25.5 26.6 27.6 28.7 30.2 31.5 Max. 27.7 28.5 Max. 27.7 28.5 29.8 32.6 33.7 35.2 36.5 6 7 8 9 12 18 21 24 26 31 3.2 4 6 4 6 6 8 6 7 8 12 13 26 31 AS1001FM-23 AS1001FM-04 AS1001FM-06 AS2001FM-04 AS2001FM-06 AS2051FM-06 AS2051FM-08 AS1001FM
System construction status No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End EX600 EX600 EX600 EX600 EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -SEN3 plate -LAB1 -LAB1 -LBB1 -LBB1 -127No.EX-OMX1011 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen.
8 70.6 [72.8] 39 V100 2-5.5 (For mounting) 1/8 (P, R port) SY SYJ (Pitch) P=19 20 Manual override Approx. 300 (Lead wire length) VK (Station n) (Station 1) VZ (Light/Surge voltage suppressor) VT + + + + VP 57 [64] 41.6 VG 25 VP 1/8 (A port) S070 VQ 23 8 19.5 VKF (Pitch) P=19 VQZ 20 VZ DIN terminal (D) M8 connector (WO) L plug connector (L) M plug connector (M) VS VFN 53.5 53.5 53.5 53.5
CX D-Z7/Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BAL Bore size (mm) DB A C D C D C D -X 6 10 15 20 25 32 11.5 (10) 20.5 (19) 13 22 5.5 14.5 24.5 15.5 18.5 (17) 18.5 (17) 20 20 12.5 12.5 22.5 22.5 2026.5 (25) 20.5 (19) 28 22 20.5 14.5 24.5 30.5 34 (32.5) 23 (21.5) 36 24.5 28 17 27 38 Data 34 (32.5) 30 (28.5) 36 31.5 28 24 34 38 44 (42.5) 35 (33.5) 46 6.5 38 29 39 48 As for auto switch
X B 5 S T D. R O D T H R E A D S T D.
Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket
Electrical entry TT is approved for Class I, II, III, Division 1, Groups A, B, C, D, E, F, G. Electrical entry L and LL is approved for Class I, Division 1, Groups A, B, C, D. 4.
Output 1 Output 2 A B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions D3 D2 L5 M2 IN L3 L2 L4 OUT IN D1 M1 M1 Applicable tube dia. d L1 Metric Size Weight (g) Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1211F-23 3.2 11.4 8.4 52 6.2 25.7 36.1 17.5 12.7 12.9
E R (N)AS S E R I E S W I T H O N E-T O U C H F I T T I N G S 1F NAS A R E A C O D E A P P L I C A B L E T U B E OD Japan, Asia, Australia, UK N Canada, USA MM 23 3.2 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 B O D Y S I Z E 1 M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard T H R E A D P O R T S I Z E M5 ...M5 U01 ..1/8 U02 ..1/4 U03 ..3/8 U04
end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10 x 1.25 6 17 19.6 16.5 JS40 nut M14 x 1.5 8 22 25.4 21 H B JS63 nut M18 x 1.5 11 27 31.2 26 10-19-14
5 7 8 7 10 13 17 22 27 14.4 19 24.8 29 38.4 49.2 17 23 29.9 33.5 38 47.5 80 210 JS20-8-125 JS32-10-125 M8 x 1.25 M10 x 1.25 43.9 49.5 1100 2500 6000 11000 JS40-14-150 JS63-18-150 M14 x 1.5 M18 x 1.5 60 74.5 11 13.5 Rod end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size