150FS Standard Specications Item Model IDF100FS-30 IDF125FS-30 IDF150FS-30 Fluid Inlet air temperature Compressed air 41 to 140F (5 to 60C) Inlet air pressure 22 to 145 psi (0.15 to 1.0)/22 to 232 psi (0.15 to 1.6 (Option K) Ambient temperature (humidity) 36 to 113F (2 to 45F) (Relative humidity 85% or less) Operating Outlet air pressure dew point set range Note 2), Note 3) 50 to 86F (10 to 30F
32" 3/16" 1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min} Effective area (mm2) 7.6 9.1 10.7 18.3 19.8 2.7 4.5 1.1 5.3 Note) Flow rate values are measured at 0.5 MPa and 20C. 15-9-14 Dual Speed Controller with One-touch Fitting Series ASD How to Order ASD 3 30F
21 286 12.5 a0 230 1 4 40 1 5 25 80 226 0 40 162 130 214 235 306 65 14.0 8 1 244 $et'ies CtA [ul0 $wllrh Standard ifications Reed oil 300m/S3 5Ol\rO or more under the test Nole l) 1500 VAC 1 min 14-1,10.F {Note 2) IEC spec 1P67, JlSC0920 Oil Prool Note l) Lead wire entry: conneclor type and D-9 type: 1000 VAC 1 min (Bet/veen case and cabte).
ft diagEm E : With indicator light and surco voltage suppssor i e l s I 3 14' 6 , ' , Lr 2.09 (s3) 2.72 (6e) 3.35 (85) 3.98 (101) 4.61 (117) 5.24 (i33) (i4e) 6.50 (165) (i&) (197) 8.39 (2|3) (?
WETTED MATERIALS Polysulfone, Silicone, Stainless steel SUPPLY CONSUMPTION See Graph MAX SUPPLY 35 PSI (242 kPa) TEMPERATURE RANGE 40 150 F (4 66 C) EFFECT OF SUPPLY VARIATION < 0.02 PSI (0.14 kPa) per 1 PSI (6.89 kPa) supply change when dead-ended REPEATABILITY < +/0.05 PSI (.35 kPa) DRIFT < .03 PSI (.21 kPa) after 24 hours RECOMMENDED FILTRATION 5 micron Part Number Description F-4103-30F
Operation 4.1 MECHATROLINK-III Communications Settings This section describes the switch settings necessary for MECHATROLINK-III communications. 4.1.1 Setting Switches S1, S2, and S3 The DIP switch S3 is used to make the settings for MECHATROLINK-III communications.
STO 13.3.3 3.2.2 ISO/EN ISO 13849-1 3 PL d 24 V EMG S4 S3 KM1 S2 KM1 K3 +24 V XS0 XS1 Z00 Z10 Z20 KM1 MELSEC (QS90SR2S) KM1 X0 COM0 24G X1 COM1 Z01 Z11 Z21 CN8 STO1 S1 EMG () STO2 STOCO M K3 TOFB1 TOFCOM 0 V TOFB2 20 S1STO (STO ) S2(STO ) S3ON S4OFF KM1 K3 EMG CN3 EM1 EM2 M . STOS1EMG0 STO[AL. 63 STO] 13.
lh.r XTOlG2i 't3 thock pd NXTO1010 ta NXrOl t3 DIRECTIOI{AL AIR VALVE DIMENSIONS/PARTS LIST SERIES NVS 3115,3125 NVS 3135, 3145 NVS 3135 NVS 3145 DIMENSIONS Valve Slzs A B c D E F G H J K M N P NVS 3135 5.98 (152) 2.56 (65) 2.01 (s1) 0.75 (19) 0.35 (s) 1.38 (35) 1.77 {45) 2.56 (65) 2.52 (64) 1.97 (50) 0.98 (25) (s0) 0.98 (25) NVS 3145 8.46 Pr5) 3.46 (88) 2.80 (71) 1.38 (35) o.47 (121 2.09 .s3
.: MELSECNET MINI-S3 Data Link System B C4 C6 4 One-touch fitting 6 One-touch fitting Mixed M When creating the mixed specifications, complete the stations table on the right.
The display End will be replaced by 0.0, Program P1 P8 Step S1 50.0 68.0 S2 300.0 30.5 S3 30.0 S0 End End leading to the input STEP 1. Press LEFT 2 times. Blinking Blinking is shifted to 0, the first decimal point. Press UP 5 times to set value of 5. Press WRITE one time. Press LEFT 3 times to shift the blinking cursor.
Input program shown below: Program P1 P8 Step S1 50.0 68.0 S2 300.0 30.5 S3 30.0 S0 End End Turn the controller switching mode to PROGRAM. Press WRITE for 2 times. The display End will be replaced by 0.0, leading to the input STEP 1. Press LEFT for 2 times. Blinking is shifted to 0, the first decimal point. Press UP for 5 times to set value of 5.
Communication connector Power supply connector PROFIBUS DP S1 S2 S3 S4 Preset pressure OFF OFF OFF OFF P01 ON OFF ON ON P14 ON OFF OFF OFF P02 OFF ON ON ON P15 OFF ON OFF OFF P03 ON ON ON ON P16 ON ON OFF OFF P04 OFF OFF ON OFF P05 1 4 4 5 2 2 3 3 1 For safety reasons, it is recommended that one of the preset pressures be set to 0 MPa.
specfcatpns on a man i)d spe.ilicalDn sheel (Note thal doubteand 3 posiuo. vatves nnol be usedwhere sinqle solenodwtrng has been specitied ) A, B port size (metric) A, B port size (inch) SSsV E series I DIN rail length 2 stalions Nore 1) Double wiring spcilication I sialions 2 stalions Noie 4 Specified layout (Up to l6solenods possible.) 6 slations Mibubishi Eleclric C,omoralion: MELSECNETA,IINI-S3
100 25 LECSA -S1 S3 200 32 LECSA -S3 S4 400 40 LECSA2-S4 Motor option Stroke [mm] 100 25 LECSB -S5 LECSC -S5 LECSS -S5 Motor mounting position S6 Nil Without option B With lock 100 100 to to 1000 1000 Refer to the applicable stroke table.
Do not scratch or put foreign matter on the O-ring, as this will cause air leakage. 1.2-153 SY3000/5000 Base Mounted Type Manifold Stacking Type/DIN Rail Mount Serial Transmission (Integrated) Type45S How to Order Manifolds How to Order Manifold Assemblies (Example) -Q U 3 N 45S SS5Y 05 C6 Manifold series 3 SY3000 5 SY5000 SI unit type Symbol Specification Without SI unit MELSECNET/MINI-S3
300 10 300 6 300 2 30 400 15 400 8 400 3 40 500 20 500 10 500 4 50 600 25 600 13 600 5 60 700 30 700 15 700 6 80 800 40 800 20 800 7 100 900 50 900 25 900 8 150 1000 75 1000 38 1000 9 200 1200 100 1200 50 1200 10 250 1400 125 1400 63 1400 11 300 1600 150 1600 75 1600 12 350 1800 175 1800 88 1800 13 400 2000 200 2000 100 2000 14 450 2500 225 2500 113 2500 15 500 3000 250 3000 125 3000 LEY25A
M There are currently 3 versions available: version 1 products (V1.m or S1.m), version 2 products (V2.m or S2.m), and version 3 products (V3.m or S3.m). Keep in mind that in order to write a backup file (.bkp) to another controller with the JXC-BCW, it needs to be the same version as the controller that created the file.
consumption Tiro TVpe of Manifold Options Compact size with large flow Model (Seies) Manifold pitch (mml Rubber seal Appicable cylinder size (mm) Cv sv1m0 10.5 0.28 Up to o50 Gassette base type manifold (Series SV1000/2000) Cassette base type manifolds offer the ultimate in flexibility. lvlanifold sections can be added using a simple release mechanism. sv2(x)0 16.0 0.48 Up to o80 SV3O(D 20.5 0.s3
NI = Carbon Steel with Electroless Nickel Plating* S3 = 303 Stainless Steel Passivated* S6 = 316 Stainless Steel Electropolished* Seal Code: Blank = Nitrile A = Aflas* W = Ethylene Propylene Y = Fluorocarbon Z = Neoprene For Perfluoroelastomer Seal Option Contact the Division.
Refer to pages 15-8-3 and 15-8-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-10-1 2 Series ASP How to Order ASP 3 30F 01 06 S Pilot check valve With seal Body size Applicable tubing O.D.