Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 35 x 4.186 x 103 x 3.0 60 = = qm x C x (T2 T1) 860 Q = = 7325 [J/s] 7325 [W] = 7.3 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 7.3 [kW] x 1.2 = 8.8 [kW] 1 x 35 x 60 x 1.0 x 103 x 3.0 860 = Q: Heat generation T1: Outlet Thermo-chiller temperature amount Customer equipment T = T2 T1 7325 [W] = 7.3 [kW]

Q = qm x C x (T2 T1) x qv x C x iT 60 1 x 70 x 4.186 x 103 x 4.0 60 = = qm x C x (T2 T1) 860 Q = = 19535 [J/s] 19535 [W] = 19.5 [kW] x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 19.5 [kW] x 1.2 = 23.4 [kW] 1 x 70 x 60 x 1.0 x 103 x 4.0 860 = Thermo-chiller T1: Outlet temperature Q: Heat generation amount 1680 [cal/h] 860 Users equipment = T = T2 T1

Silent interval is indicated by T1-T2-T3-T4. Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).

Silent interval is indicated by T1-T2-T3-T4. Table 3.8-2 RTU mode message frame a)Start b)Slave Address c)Function d)Data e) Checksum (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (non-communication time).

Applicable model D5 L9 L10 L11 L12 L13 L14 L15 L16 L17 t1 AS-10L AS1002F3.4 14.8 18.3 11 27.5 19.5 3.4 4.9 7.3 12 1 AS-20L AS2002F 15.6 19.6 12.6 29 21 1.2 AS-25L AS2052F 4.5 19.6 24.6 17 38 28 4.5 6.5 9.5 15.5 AS-30L AS3002F 24.8 29.8 22 43 33 1.4 AS-40L AS4002F 25.7 30.7 28 49 39 3.5 18.2 23.2 11 3.5 18 11.3 1.6 AS-20D AS2002F 18.6 23.6 12.6 19.6 AS-25D AS2052F 4.5 4.4 22 27 17 4.4 25.8

Dimension AS220M01 02 AS120M H (width across flats) 8 L1 T2 24.8 (Max. 29.8) M5 x 0.8 28.2 (Max. 33.2) L2 A D1 9 10.3 L3 10 M5 x 0.8 10-32UNF D2 T1 9 Dimensions A L2 L3 T1 T2 H L1 Model D1 D2 Min. Min. Max. Max.

^ 9troh6 056 ('g/s') 5 t b 3.5 lb/in 1.75 lblin 075 \%') 6.5 tb 4 lb/in 2 lb/in 106 (1%;) 7.75 tb 4 lblin 2 lblin 150 t1%') 8 r b 3.4 lb/in 1.7 lblin 2OO 12\ 1 2 t b 8 lb/in 3 lblin 250 (2%') 18.75 tb 8.25lblin 3.5 lb/in 300 (3) 23 rb 10.5 lb/in 3.75 lb/in 400 (4') 26.5 tb 8.5 lblin 3.5 lb/in Series NCQT Constru.ction Spring Retum Rubber Bumper Double Ac'ting Sgring Extend 1 4 Bumper B Urethane

D C D D CQ-M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L CQ-M5 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 125L x 150L CQ-M6 x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 135L x 160L x 185L x 210L CQ-M8 x 75L x 80L x 85L x 90L x 95L x 100L x 105L x 110L x 115L x 120L x 145L x 170L x 195L x 220L x 245L C Model Mounting bolt

s o.50 o.8e4 o93 0.75 0.18 %-18 0.50 0.95 2.94 106 (1 0.312 %-24 0.50 o.624 0.25 1.12 o.12 0.88 0.88 0.24 %-8 0.62 1.17 3.25 0.la7 Wzo 0.75 0.7i19 o 1.t2 0.25 1.06 'L06 o.25 %-16 ora 1.62 400 150 t1%l o.87 1h-20 o_75 o.749 0.38 1.56 0.25 1.25 1.25 o.25 3l-16 0.88 '1.50 3.69 Double End : NC.

Relationship Between Flow Rate and Pressure Difference (Representative values) 100 [Inrush] 90 80 70 60 50 40 30 20 10 0 0 0.05 0.1 0.15 0.2 0.25 Pressure difference [MPa] Flow rate [L/min (ANR)] Rated voltage SX090 [Holding] SX91 1 2 35% (SX090) 42% (SX9 ) of rated voltage 0 V SX92 100 10 ms T1 (ON) (2 s or more) T2 (OFF) Energized condition 1 Low Profile 2/3-Port Solenoid Valve SX90/090

bar absolute, T1 = 297 5K, 0.07 bar DP 0.14 bar.

Mounting bolt Mounting bolt diagram C D D Model C Mounting bolt Model C D Mounting bolt M5 x 55l x 60l x 65l x 70l x 75l M8 x 95l x 100l x 105l x 110l x 115l CHQB63 10D (M) 5D (M) CH QB20 55 60 65 70 75 80 85 90 95 100 70 75 80 85 90 95 100 105 110 115 140 165 75 80 85 90 95 100 105 110 115 120 145 170 90 95 100 105 110 115 120 125 130 155 180 95 100 105 110 115 120 125 130 135 160 185 100

T=T2 T1 Output (shaft power, etc.)

Circulating device Users equipment L 0.8 x 3 x 1 x 103 x 4.2 x 103 = T = T2 T1 60 x 1000 = 167 W T1: Outlet temperature 200 W Cooling capacity = Considering a safety factor of 20%, 167 W x 1.2 = Example 3 When cooling the object below a certain temperature in certain period of time.

Power supply 11) 100/110V AC (50/60Hz) 200/220V AC (50/60Hz) 21) 1) Consult SMC if the supply voltage for LC1-1HV1 will be 110V AC or more, or the supply voltage for LC1-1HV2 will be 220V AC or more. or LC1-1-T1(Teaching box) are required.

L1 Dimensions A Model T2 H D1 T1 D2 D3 L3 L1 L4 L2 AS12 0-M5-T M5 x 0.8 8 9 M5 x 0.8 9 4.5 10 31 10.3 0.7 28.4 AS12 0-U10/32-T 10-32UNF 10-32UNF AS22 0-01-ST Rc 1/8 12 14.3 R 1/8 AS22 0-F01-ST PF 1/8 14.6 7 18 35.6 14.1 1.5 32 AS22 0-N01-ST NPT 1/8 12.7 NPT 1/8 AS22 0-02-ST Rc 1/4 17 18 R 1/4 AS22 0-F02-ST PF 1/4 19.5 7 27.2 40.7 18 1.5 36.7 AS22 0-N02-ST NPT 1/4 17.5 NPT 1/4 AS32 0-02-

Applicable model D5 L9 L10 L11 L12 L13 L14 L15 L16 L17 t1 AS-10L AS1002FS3.4 14.8 18.3 11 27.5 19.5 3.4 4.9 7.3 12 1 AS-20L AS2002FS 15.6 19.6 12.6 29 21 1.2 AS-25L AS2052FS 19.6 24.6 17 38 28 AS-30L AS3002FS4.5 24.8 29.8 22 43 33 4.5 6.5 9.5 15.5 1.4 AS-40L AS4002FS 25.7 30.7 28 49 39 Part no.

T [s] = (V/10) x (T2 T1 )/(Z) T [s] = (5/10) x (12 3.7) = 4.2 Increase number of booster regulators (Z) to decrease T. NO NO Extend stop time Ts up to charge time T or more. Judgement of charge time T Ts 4.2 29 YES YES When running continuously for a longer period of time, confirm the life expectancy.

ASS Dimensions ASR AS220M-01 02 AS120M ASF H 8 (Hexagon width across flats) L1 T2 24.8 (MAX. 29.8) 28.2 (MAX. 33.2) M5 x 0.8 L2 A L3 D1 9 10.3 10 M5 x 0.8 10-32 UNF D2 T1 9 Dimensions A L2 L3 T1 T2 H L1 D1 D2 Model Min. Min. Max. Max.