Stations: 5 Stations, Cylinder Port Size: One-touch Fitting for ø4, P, R Port Size: One-touch Fitting for ø8, Kit: w/o Serial Unit, SI Unit COM.: +COM. (or w/o SI Unit), Option 1: w/o DIN, w/Bracket, Option 2: N+S
Stations: 4 Stations, Cylinder Port Size: 5/32" One-touch Fitting, P, R Port Size: 1/4" One-touch Fitting, Kit: DeviceNetâ„¢ for 32 Points, Communication Connector: T-branch Type (or None w/o SI Unit), SI Unit Common: Positive Common (or None w/o SI Unit), Option 1: w/o DIN Rail, w/Bracket, Option 2: Built-in Silencer
+ -+ R P R P P port 1/4 R port 1/4 P port 1/8 R port 1/8 Note) If there are more than 6 stations for type 20, or more than 9 stations for 21 type, supply air to both sides of P port and exhaust air from both sides of R port.
with the manifold base model no. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 (Example) SS5YJA3-41-03-M5 1 pc.
SYJ3000-21-2A 1 pc. 5(R) 1 (P) (R)3 3(R) 1 (P) 3 position pressure center 3 position pressure center The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 4(A) (B)2 4(A) (B)2 5(R) 1 (P) (R)3 3(R) 1 (P) Caution Be sure to read this before handling the products.
P Part in contact with fluid A part that comes into physical contact with the fluid. Pressure characteristics The amount of variation in the analogue output or display value when the supply pressure is changed. Proof pressure The pressure beyond which the flow switch will be damaged. R Rated flow range The flow range within which the product will meet all published specifications.
Actuation: 1 (Normally Closed), Piping: 3 (Standard, Body Ported), Voltage: S (5 VDC), Electrical Entry: MO (w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: PM3 (Body Ported for P, R, A Port), Bracket: F (w/Bracket)
Model: 10S (Side Ported), SI Unit Specification: 0 (w/o SI Unit), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 16 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: R (External Pilot), A,B Port Size: C10 (ø10 One-touch Fitting, Straight, Metric), Mounting: AA (Direct Mounting, Name Plate w/Station Number)
Stations: 9 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N9 (One-touch Fitting for 5/16"), Kit: FD0 (D-sub Connector, 25P, w/o Cable), Option 1: D0 (w/o DIN, w/Bracket)
Pilot valve symbol 1 2 3 4 5 6 100 AC 200 AC 110 AC 220 AC 24 DC 12 DC q w e r t y u i Nil Y Nil Y Nil Nil Nil Nil K1 K1 J1 J1 Q1 Q2 N1 N2 Combinations (1) to (8) in the above table are the only possible options. 850
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Stations: 9 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N9 (One-touch Fitting for 5/16"), Kit: FD1 (D-sub Connector, 25P, w/1.5m Cable), Option 1: D0 (w/o DIN, w/Bracket)
: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)