SMC Corporation of America
Elite Part Number Search
Search Results "RS2H50TN-30DM-DC-M9PSAPC"

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 6, Valves: Not Provided, Allowable Kinetic Energy(J): 0.001, Operating Pressure Range(MPa

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 6, Valves: Not Provided, Allowable Kinetic Energy(J): 0.001, Operating Pressure Range(MPa

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 8, Valves: Not Provided, Allowable Kinetic Energy(J): 0.0015, Operating Pressure Range(MPa

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating Pressure Range(MPa

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure

Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure

Sensor Type: Non-Contact, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Wiring type: 3-wire type, Output Type: PNP type, Electrical entry direction: In-line, Lead wire length(m): 0.5, Connector Type: M8 3-pin

NPN open collector output Brown (DC 24V) Terminal NO.12 Wire the Black (Output1) communication cable to the Blue (DC COM) connector included as an Terminal NO.1 accessory.

A.STP Changing of DC line fuse cut Set the operation when the alarm No. AL21 DC line fuse cut is generated.

A.STP Changing of DC line fuse cut Set the operation when the alarm No. AL21 DC line fuse cut is generated.

NPN open collector output Brown (DC 24V) Terminal NO.12 Wire the Black (Output) communication cable to the Blue (DC COM) connector included as an Terminal NO.1 accessory.

NPN open collector output Brown (DC 24V) Terminal NO.12 Wire the communication cable to the Black (Output) Blue (DC COM) connector included as an accessory.

NPN open collector output Brown (DC 24V) Terminal NO.12 Wire the communication cable to the Black (Output) Blue (DC COM) connector included as an accessory.

NPN open collector output Brown (DC 24V) Terminal NO.12 Wire the communication cable to the Black (Output) Blue (DC COM) connector included as an accessory.

Auto Switch Internal Circuits Solid state switches D-H7A1 D-H7A2 D-H7B, D-H7C DC (+) Brown [Red] OUT (+) Brown [Red] DC (+) Brown [Red] Main switch circuit Main switch circuit Main switch circuit OUT Black [White] OUT Black [White] DC () Blue [Black] DC () Blue [Black] OUT () Blue [Black] D-H7PW D-G5NTL D-H7LF DC (+) Brown [Red] DC (+) Brown [Red] DC (+) Brown [Red] OUT (normal output) Black

Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None Internal resistance 1 or less (including lead wire length of 3 m) D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

D-Y7NW(V) Auto Switch Weight Table DC (+) Brown [Red] Unit: g Main switch circuit OUT Black [White] D-Y7BW D-Y7PW Model D-Y7NW 11 11 11 Lead wire length 0.5m 54 54 54 Lead wire length 3m DC () Blue [Black] Auto Switch Dimensions D-Y7PW(V) D-Y7W DC (+) Brown [Red] Main switch circuit OUT Black [White] DC () Blue [Black] D-Y7BW(V) OUT (+) Brown [Red] Main switch circuit D-Y7WV OUT () Blue [

Rectifying device Rectifying device ZNR ZNR 1 (+, ) Series VQ20/30 1 Grommet Black () DC SOL. SOL.

Changing a coil from AC to DC is possible, but it's impossible to change from DC to AC. (Hum sound may generate because of no shading coil for DC.) Return voltage is 20% or more of the rated value at AC power and 2% or more at the DC power. Allowable voltage fluctuation is 10% of the rated voltage.

Without indicator light Without indicator light 2 () 2 Without indicator light Without indicator light Conduit terminal, DIN terminal DC circuit DC circuit AC circuit 1 (+, ) 1 (+, ) 1 SOL. SOL.