The special cable is packed with the teaching box. (2 to 5m) 61 Series LC1 How to Order Performance/Specifications LC1 1 T1 0 General Specifications LC1-1-T1-0 Power supply Supplied from LC1 Dimensions (mm) 169 x 76 x 20 Weight ( g ) 158 Case type Resin case Display unit 46 x 55 liquid crystal screen Cable length Operating unit Keyswitches, LED indicators 2 3 4 5 2m 3m 4m 5m Cable length

Sealmaterial Part numbers indicating changed seal material and leakage XVD Compound No. 1349-80 2101-80 Symbol Leakage (Pam3/s or less) Note 1) Internal 1.3 x 10-10 (FKM) 1.3 x 10-8 Changed part Note 2) Seal material FKM EPDM Barrel Perfluoro Symbol External 1.3 x 10-11 (FKM) 1.3 x 10-9 Nil XGT w, e w e N1 Nil A B C P1 70W 1.3 x 10-11 (FKM) 1.3 x 10-9 1.3 x 10-8 CYV Kalrez Q1 R1 R2 R3 S1 T1

OUT2 OUT1 CH.B CH.A OUT2 OUT1 CH.B CH.A OUT2 OUT1 CH.B CH.A ZSE2 ISE2 Select "LED2 display mode" by pressing the G button. LED2 display Select "OUT2 output mode" by pressing the G button. LED2 display : Normal mode : Reversed output mode Select "OUT1 output mode" by pressing the G button.

Conversely, due to the operation of the switching valve that occurs after a certain length of time, T1 becomes reactivated and T2 assumes the adsorption state. This process is repeated to continuously provide dry air.

(Refer to Precautions on page 16-2-24 for details.) 1.5 01: R 1/8 T1: NPT 1/8 Data ZSE40(F)/ISE40-W1 2-M4 x 0.7 thread depth 4 20 30 Rc 1/8 MPa 7 19 20 30 OUT2 OUT1 SET 6.5 R 6.4 18.35 Atmospheric release port Lead wire length 600 (3000) 3.5 12.4 7.8 7 2.5 2.6 30 15.2 42 10.7 4 6 For splash proof use (IP65), insert an air tube into the atmospheric release port.

Speed:V [mm/s] a1 a2 Reaches the target position T = T1 + T2 + T3 + T4 [s] P T1: Acceleration time and T3: Deceleration time can be obtained by the following equation.

Options Description Model Material Bracket B21-1-T1 Rolled steel plate (electroless nickel plated) Specifications M5, Rc 1/8 Connection port size Air, N2, CO2, Ar Fluid Proof pressure MPa 1.5 Maximum operating pressure MPa 1.0 0.005 to 0.2 Low pressure type Regulating pressure range MPa 0.01 to 0.4 High pressure type Ambient and fluid temperature (C) 0 to 60 Fluid consumption l/min (ANR)

Change circulating fluid setting temperature.Set the pump output (option T1 only).

ZSE2 ISE2 ZSP Environment Installation ISl Caution Caution qIf the Air Catch Sensor is mounted in an enclosure, make sure that the exhaust port is open to atmospheric pressure to avoid malfunction due to possible pressure build-up inside the enclosure. wConnect the tubing via the M5 fittings to the Air Catch Sensor.

-25 NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ZSE401 T1-26 Vacuum Analog output 1~5V (+ 5%F.S.), load impedance : 1k ZSE401 T1-65 PNP output PNP open collector 80mA ISE4L01 T1-25 Positive Pressure NPN output NPN open collector 30V, 80mA, residual voltage: 1V or less ISE4L01 T1-26 100kPa Analog output 1~5V (+ 5%F.S.), load impedance: 1k ISE4L01 T1-65 (14.5PSI) Type

Option symbol T1 Inverter Pump Mounted HRR010 20 T1 Inverter pump mounted Possible to choose an inverter pump in accordance with users piping resistance Cooling capacity will decrease by heat generated in the pump. The inverter pump does not use a mechanical seal. The 50 Hz and the 60 Hz inverter pumps have the same capacity.

ZSP1-0X-15CN 1 pc. ZS-10-5 A-50 1 pc. 0.6 m 30 3 m 50 5 m Specifications Model ZSP1-B ZSP1-S Fluid Air Operating pressure range 20 to 101 kPa Applicable adsorption nozzle dia. 0.3 to 0.7 (Refer to Graph (1) on page 16-7-3.) 0.5 to 1.2 (Refer to Graph (2) on page 16-7-3.)

Time [s] Method 2: Calculation T1 T2 T3 T4 T5 T6 Cycle time T can be found from the following equation. L : Stroke [mm] V : Speed [mm/s] a1: Acceleration [mm/s2] a2: Deceleration [mm/s2] T = T1 + T2 + T3 + T4 [s] Calculation example) T1 to T4 can be calculated as follows. T1 and T3 can be obtained by the following equation.

Note 2) Splash proof specification is not available for F and T1.

-02 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Performance/Specifications General specifications LC5-1-T1-02 Part no.

ZSP1-0X-15CN 1 pc. ZS-10-5 A-50 1 pc. 0.6 m 30 3 m 50 5 m Specifications Model ZSP1-B ZSP1-S Fluid Air Operating pressure range 20 to 101 kPa Applicable adsorption nozzle dia. 0.3 to 0.7 (Refer to Graph (1) on page 16-7-3.) 0.5 to 1.2 (Refer to Graph (2) on page 16-7-3.)

L Speed: V [mm/s] Calculation example) T1 to T4 can be calculated as follows. a1 a2 Time [s] T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] T = T1 + T2 + T3 + T4 [s] T1 T2 T3 T4 L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration T2 = L : Stroke [mm] time can be obtained by the following equation. 200 0.5 300 (0.1 + 0.1) 300 (Operating condition) V : Speed