This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AMH 1/4INCH MODULAR (PT), AIRLINE EQUIPMENT, AMH MICRO MIST SEPARATOR, DA, AMH 1/4INCH MODULAR (PT), 1.15363 lb, ModelNote)Rated flow (l/min (ANR))Port sizeMass (kg)AMH150C2001 8, 1 40.38
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, M'BRANE W/SEPARATOR, OTHERS, IDG MEMBRANE AIR DRYER, EX, IDG 3/8 MEMBRANE AIR DRYER, 6.17294 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, DA, AC MASS PRO 1/4 MODULAR (PT), 4.6297 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, MEMBRANE W/SEP/REG, OTHERS, IDG MEMBRANE AIR DRYER, DX, IDG 1/4 MEMBRANE AIR DRYER, 2.71903 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, DA, AC MASS PRO 1/4 MODULAR (PT), 2.35160 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, DA, AC MASS PRO 1/4 MODULAR (PT), 2.20094 lb
Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
For applications requiring micro-mist separation up to 0.1µm with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set
For applications requiring micro-mist separation up to 0.1µm with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set
Combining a mist separator and regulator into one unit simplifies piping and installation. This combination controls the filtration to 0.3µm, for applications that require cleaner air than regular filtration, such as air blow off. As part of the family of modular air preparation units, the AWM can be combined with other similar sized products. This series is available with port sizes from
Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style. Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, N/PLUG-IN, SQ2000, VALVE, SS5Q2 MANIFOLD SQ2000, 2M, SS5Q2 NO SIZE RATING, 1.35032 lb
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF3000 series manifold, Metric threads [Rc(PT)], Manifold type: S mount, Maximum stations: 10, Port sizes: 1/8, 1/4, Common
SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone
MANIFOLD, 4 STA, AIR OPERATED VALVE, 468 lb
Part Number Description: MFLD, BASE MT Product Line: V Product Line Description: VALVE PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
Part Number Description: MFLD, BASE MT Product Line: V Product Line Description: VALVE PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 3.52739 lb