SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-N15L-P1-M2"

No.0.8 L1 L3 L2 L3 (L4) No.0.8 H 2 H 2 H 2 L1 M1 M1 M1 D Pad side Pad side Pad side ZP2V-A01ZP2V-AN1ZP2V-AG1ZP2V-A5ZP2V-A8Vacuum generator side D Vacuum generator side M2 M2 L3 L2 H 1 Vacuum generator side L2 L3 3 H 1 M2 H 1 (L4) (L4) No.0.8 No.0.8 (L4) No.0.8 H 2 H 2 L1 L1 L1 H 2 M1 M1 M1 Pad side Pad side Pad side ZP2V-B01ZP2V-BN1ZP2V-BG1ZP2V-B5ZP2V-B61 The place at the vacuum generator

M1 = W1 x L1 M2 = W3 x L3 NO L3 L1 NO M1 YES The product is operatable at 14.5 mT or less magnetic field ? Is there any influence from magnetic fields ? (Refer to Caution on Handling on pages 6 and 7.) M2 W1 W3 YES NO M1 = W4 x L3 M2 = W1 x L2 NO Do not use it since it will result in a miscount. L3 L2 M1 YES Is cylinder exposed to oil, coolant, powder etc. ?

(Nm) ML2B/M1 (Pitch moment) ML2B/M2 (Roll moment) ML2B/M3 (Yaw moment) Pitch moment M1/M1e 10 20 40 Roll moment M2 1.2 2.4 4.8 Yaw moment M3/M3e 3.0 6.0 12 MI W S 40 Model 20 30 YES 20 5 4 3 10 ML2B25 ML2B32 ML2B40 CEP1 If speed or load changes, stopping time may vary and positioning accuracy may be compromised.

Maintenance space For encoder connecter Screw size: M2 Tightening torque: .1 Nm M2 0.1Nm Reserve sufficient space for maintenance. 16. Mounting connectors For brake connecter Screw size: M2 Tightening torque: 0.2 Nm M2 0.2Nm Tighten the screws evenly. Tightening torques are as indicated below.

Bore size Hexagon socket set screw Hexagon width across flats Tightening torque (Nm) 0.176 0.176 0.63 1.5 1.5 0.9 0.9 1.5 2 2 M2 x 6 M2 x 6 M3 x 8 M4 x 8 M4 x 8 8 12 20 25 32 Retaining ring Retaining ring Cap O-ring set screw hole O-ring Cap Hexagon socket set screw 390 Series MIW/MIS Replacement Procedure of Finger/Seal 2 2-4.

Thin shaft Position of rotational axis: Perpendicular to the shaft, and attached near one end CKQ = m1 + m2 a12 3 a22 = m1 + m2 4a12 + b2 4a22 + b2 3 12 12 2. Thin shaft Position of rotational axis: Perpendicular to the shaft, and attached at the center of gravity 5.

LOAD WEIGHT (G) P R O D U C T SPECIFICATION ALLOWABLE MOMENT Model Stroke M1 M2 M3 Cp.Cy Cr MXU6 5 0.046 0.040 0.049 28.3 7.5 10 0.046 0.040 0.049 28.3 15 0.061 0.053 0.062 31.5 20 0.061 0.053 0.062 34 25 0.076 0.066 0.074 38.5 30 0.076 0.066 0.074 41 MXU10 5 0.047 0.041 0.109 28.5 9.5 10 0.047 0.041 0.109 31 15 0.080 0.069 0.169 36 20 0.080 0.069 0.169 38.5 25 0.103 0.089 0.212 44 30 0.103

(mm) Model L Q Weight (g) 2-applicable tubing M2 D KGL04-00 18 4 6 8 10 16 17 18.5 21 10.4 4.5 4.2 4.2 6 KGL06-00 20 12.8 5.3 11.4 9.0 6 KGL08-00 23 15.2 6 21.6 14.9 10 KGL10-00 26.5 18.2 6.8 35.2 25.0 17 KGL12-00 28.5 20.9 7.5 50.2 39.7 21 12 22 KGL16-00 34 26.5 10 100 (84) 29 16 25 K Note 1) D: Max. diameter Note 2) ( ): Values for nylon.

Output Output 3 B Output 1 Output 2 A B C A B A Dimensions (mm) 1in = 25.4mm 1g = 0.0353 oz D3 Metric sizes: Light gray Inch sizes: Orange D2 L5 M2 IN Blue L3 L2 L4 OUT IN D1 M1 Applicable tubing O.D. d M1 L1 Metric sizes: Light gray Inch sizes: Orange Metric sizes Weight g Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1210F-23 3.2 11.4 8.4 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 VR1210F-04 4 12.8

Tightening Torque for Piping Proper tightening torque Nm 0.1 to 0.14 Thread size Model Base mounted LVM09R3, 09R4, 095R M2 Body ported LVM11 1.5 to 2 M5 Note) Without sub-plate M2 0.15 to 0.2 Base mounted LVM10R3,10R4, 10R6,105R Maintenance M6 or 1/4-28UNF With sub-plate 1.5 to 2 Warning Base mounted LVM15R3, 15R4, 155R M2.5 0.25 to 0.35 1.

Output Output 3 B Output 1 Output 2 A B C A B A Dimensions Metric sizes: Light gray Inch sizes: Orange D2 L5 M2 IN Blue L3 L2 L4 OUT IN D1 M1 M1 Applicable tubing O.D. d L1 Metric sizes: Light gray Inch sizes: Orange D3 Metric sizes Weight g Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 3.2 11.4 8.4 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 VR1210F-23 4 12.8 10.4 56 20.3 32.2 21.9 15.7 15.8 25.2 VR1210F

Replacement pilot valve for the JSY3000/5000 b-side pilot valve 2 Pilot valve mounting screw (M2 x 16.5) Tightening torque: 0.15 Nm B tight flat head screw (M1.7) Tightening torque: 0.12 Nm 2 Pilot valve mounting screw (M2 x 25) Tightening torque: 0.15 Nm Loosen B tight flat head screw to remove the pilot cover in the direction indicated by the arrow q.

[Accumulated output mode] Set each [P1]/[P2] (set value), referring to setting method of page 27. (When reversed output is selected, the main screen displays [n1]/[n2]).

)No LinkNo Activity BUS IN (P1) LinkNo Activity BUS IN (P1) Link Activity L/A2 BUS OUT (P2)No LinkNo Activity BUS OUT (P2) LinkNo Activity BUS OUT (P2) Link Activity 7.2 LED LED LED PWR ALM MS NS EtherNet/IP EEPROM : LED EEPROM (PWR()) * () -30- 8 8.1 No.

External Pilot Piping of pilot port [12(P1), 10(P2)] P1 and P2 piping should be as follows according to the model. Caution Port VND0D VND02D 12(P1) External Pilot Bleed port 10(P2) Bleed port External Pilot Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention.

Connect the communication cables with P1 and P2. P1 (D-sub 25P female) Cap P2 (D-sub 9P female) P3 (D-sub 9P male) Not used. (Only for maintenance) Power cable Contact signal cable Serial RS-485 communication cable Figure 3-10 Power Cable Insertion and Communication Cable Connection Correct phase rotation is required when attach the power cable to the breaker terminal.

Connect the communication cables with P1 and P2. Cap P1 (D-sub 25P female) P2 (D-sub 9P female) P3 (D-sub 9P male) Not used. (Only for maintenance) Power cable Contact signal cable Serial RS-485 communication cable Figure 3-7 Power Cable Insertion and Communication Cable Connection Correct phase rotation is required when attach the power cable to the breaker terminal.

S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa. 1.12-16