For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
Do not press the setting buttons with a sharp pointed object. This may damage the setting buttons. Supply the power when there is no flow. If using the product to detect very small flow rates, warm up the product for 10 to 15 minutes first. There will be a drift on the display or the analogue output of approximate 2 to 3% immediately after the power supply is turn on, within 10 minutes.
Do not short-circuit the load. Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause the damage of the Pressure switch. Do not press the setting buttons with a sharp pointed object. It may damage the setting buttons. If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first.
Do not stare into beam visible at XF1/XF2.
Bore size/Stroke (mm) Bore size 6 10 15 20 25 32 Standard strokes 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 Applicable Auto Switches/Refer to page 15 for detailed auto switch specifications.
Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14
Do not press the setting buttons with a sharp pointed object. It may damage the setting buttons. If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first. There will be a drift on the display of approximate 1% immediately after the power supply is turned on, within 10 minutes. Perform settings suitable for the operating conditions.
Do not use in the place creating magnetic field to prevent the malfunction of the actuator. Do not use in the environment subject to temperature cycle. Do not use where close to surge generating source. Do not short the load. Short of the load of the controller is indicated as error, but it may cause over current and break the actuator.
EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series
DDH10 (Hole) B DA DB DL DU DC DX DE DO DR DT DS DH Z 32 40 50 63 +0.058 0 54 42 32 22 10 44 14 62 9 6.6 15 7 33 224 10 MB-B03 25 45 160 32, 40 +0.058 0 63 42 32 22 10 44 14 62 9 6.6 15 7 33 235 10 +0.070 0 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 271 14 MB-B05 40 60 190 50, 63 +0.070 0 90 53 43 30 11.5 60 20 81 10.5 9 18 8 45 285 14 80 100 +0.084 0 102 73 64 45 14 86 30 111 12.5 11 22 10
Do not modify the internal electrical wiring of the product. 10.2 Earth leakage breaker specification Models Item IDFB60-11-R IDFB60-23-R IDFB70-23-R IDFB80-23-R IDFB90-23-R Rated current (A) 15 10 15 20 30 Sensitivity current (mA) 30 IDFB60/70/80/90 Series 10.1 Safety instructions for use 10-1 IDX-OM-V024 Chapter 10 Option R 10.3 Connection of power supply Connect the power cable according
REAL40 REAL25 REAL32 Model 10 (2.48 1.3 x 10-3 x ST) 30 10 (1.98 1.3 x 10-3 x ST) 10 (2.26 1.3 x 10-3 x ST) = 50 20 2.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
4 0 4 0 10.5 7 10 6.5 40 10 10 14 14 7.5 7.5 7.5 7.5 7 7 4 4 4 4 10.5 10.5 10 10 50 11.5 10.5 15.5 14.5 9 8 9 8 8.5 7.5 5.5 4.5 5.5 4.5 12 11 11.5 10.5 63 12.5 11.5 16.5 15.5 10 9 10 9 9.5 8.5 6.5 5.5 6.5 5.5 13 12 12.5 11.5 80 17.5 14 21.5 18 15 11.5 15 11.5 14.5 11 11.5 8 11.5 8 18 14.5 17.5 14 100 17.5 15 21.5 19 15 12.5 15 12.5 14.5 12 11.5 9 11.5 9 18 15.5 17.5 15 (mm) Auto switch model
Do not press the setting buttons with a sharp pointed object. It may damage the setting buttons. If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first. There will be a drift on the display of approximate 1% immediately after the power supply is turned on, within 10 minutes. Perform settings suitable for the operating conditions.
Do not short-circuit the load. Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause the damage of the Pressure switch. Do not press the setting buttons with a sharp pointed object. It may damage the setting buttons. If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first.
A 4 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, DC24 V +10/-5%, 2 A 8 A 4 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.
Do not press the setting buttons with a sharp pointed object. It may damage the setting buttons. If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first. There will be a drift on the display of approximate 1% immediately after the power supply is turned on, within 10 minutes. Perform settings suitable for the operating conditions.
Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. 2 Analogue input range (Range) Selects the analogue input range. -10..10 V 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit. 2s complement 2s complement.
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.