SMC Corporation of America
Elite Part Number Search
Search Results "VNA111A-8A-5G-B"

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

S070 is extremely lightweight (5g for valve single unit type) and operation noise is 38dB(A) or less. It is easy to increase or decrease the number of stations (stacking base).

Push Button (Mushroom)/VM120-01-30R, B, G, Y/VM130-01-30R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 21N F.O.F. 0.5MPa supply 4.9mm P.T. 1.6mm O.T. 6.5mm T.T. Push Button (Extended)/VM120-01-32R, B, G, Y/VM130-01-32R, B, G, Y Panel mounted hole JIS Symbol 2 port 3 port 21N F.O.F. 0.5MPa supply 4.9mm P.T. 1.6mm O.T. 6.5mm T.T.

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

The VN series is a combination of process valves that can be operated with pressure differential zero and comes with many variations. The VNA series is used for controlling pneumatic systems or air-hydro circuits. The VNB series controls various fluids. VNC is used for controlling the cutting oils and coolants used in machine tools. VNH is for controlling high pressure cutting oils and coolants

(L4) (L3) (5.25) L2 L1 Top entry port Not machined 27 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

2 B 2 B 2 B 2 B 2 R 3 B 2 B 2 B 2 B 2 PE R 3 B 2 R 3 R 3 SY A 4 A 4 A 4 A 4 A 4 P 1 P 1 A 4 A 4 A 4 A 4 X P 1 P 1 A 4 2n2One-touch fitting [4(A), 2(B) port] 2One-touch fitting (X, PE ports) Applicable tubing O.D.: 6 2n1-M5 x 0.8 [4(A), 2(B) port] SYJ Applicable tubing O.D.: 4 6 SX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-

(ZP)[1][2][8][0]17bit 14 37 14 (5) ON/OFF((DO)) ON/OFF [9][0] (a) DO [8][B][0][0]0004DO 0 0 0 4 4 DO (b) ON/OFF [9][2] [A][0] b31 b 1 b 0 1 ON 0 OFF bit 16 bit CN6 bit CN6 bit CN6 bit CN6 0 14 8 16 24 1 15 9 17 25 2 16 10 18 26 3 11 19 27 4 12 20 28 5 13 21 29 6 14 22 30 7 15 23 31 (c) DO DO[8][B][0][0] [8][B] [0][0] 0 DO 14 38 14 (6) (a) [8][B][0][0]0003 0 0 0 3 3 (b) ([8][B]

A B A B A Void A Void A B A B A B A A A B Double Double Double Double Double SY Sl unit Sl unit Single Single Single Single Single SYJ Stations Stations 1 2 3 4 5 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link System (Sharp) VK VZ ADDRESS NO. STATION NO.