SMC Corporation of America
Elite Part Number Search
Search Results "VFM351-02-33"

How to Order Hexagon Socket Head Cap Screw ZQSTB 05 Fitting assembly Number of stations Clip (ZK1-CP-A) 10 pcs. in one set 01 02 1 station 2 stations Applicable tubing O.D.

AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.

AW-OMZ0062 PRODUCT NAME icro Mist Separator Regulator MODEL / Series / Product Number AWD20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWD30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWD40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure switch. Do not perform wiring while the power is on.

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. -6No.PS-OMV0009-E Wire correctly. Incorrect wiring can break the Pressure switch. Do not perform wiring while the power is on.

1.5 5 29.5 33 186 (230) 142 22.5 23.5 12 8 100 Rc3/8 112 85 85 25 40 4 60 M12 x 1.75 depth 14 5 259 (325) 1.5 5 39.5 33 245 (311) 172 28 25 12.5 8 Size AU BU CU SU MU Key Note 2) dimensions b L1 50 9.5 6 19 33 M12 x 1.75 5 0 0.030 25 63 10.5 6 22 35.5 M14 x 2 6 0 0.030 30 80 12.5 8 24 44 M16 x 2 6 0 0.030 40 The dimensions of the shaft type (W: Double shaft, X: Single shaft with four chamfers

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Applicable bore size A 0.43 D B 0.13 C No.10-32 UNF JM-02 Note 1) 0.38 7/16", 9/16" JM-025 1/4-28 UNF 0.44 0.51 0.16 3/4", 7/8" JM-03 5/16-24 UNF 0.50 0.50 0.19 1-1/16" JM-045 7/16-20 UNF 0.79 0.26 0.69 1-1/4", 1-1/2" JM-04 3/8-24 UNF 0.56 0.65 0.23 1-1/4", 1-1/2" (Non-rotating) JM-05 Note 1) 1/2-20 UNF 0.75 0.87 0.32 2" Note 1) Please order separately. (044, 056, 200 only) 46 Series NCM

The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure switch. Do not perform wiring while the power is on.

U B A Auto Switch Proper Mounting Positions (mm) Solid state auto switch Reed auto switch D-F7/J79 D-F7V/J79C D-F7W/F7WV D-F7BA/F7BAV D-F79F/J79W D-F7NT D-A9/A9V D-A73/A80 D-A7H/A80H D-A73C/A80C D-A72 D-A79W D-M9/M9V D-M9W/M9WV D-M9A/M9AV Bore size (mm) B 10.5 23 26 27.5 31.5 33 35.5 B 9.5 20.5 23.5 25 29 30.5 33 B 14.5 25.5 28.5 30 34 35.5 38 B 6.5 19 22 23.5 27.5 29 31.5 B 9 20 23 24.5

(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8

Bore size (mm) 0.1 0.3 A + Stroke A A B 82 92 CL B CL -X 102 23 33 92 102 10 to 50 75, 100 32 33 92 Individual -X Refer to page 832 for details of rod end nuts and accessory brackets.

L 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.

Description Material Note 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 No.

49 LS LS 89.2 23 33 79.2 89.2 10 to 50 75, 100 33 49 32 Rod end nut 38.5 Front flange type: CLQF32 54.2 48 34 8 4-5.5 65 56 17 32 B + Stroke A + Stroke Front flange type (mm) Stroke range Without auto switch With auto switch Bore size (mm) A B A B 82 23 33 72 82 10 to 50 75, 100 33 32 Rod end nut 38.5 Rear flange type: CLQG32 54.2 48 34 7 32 B + Stroke 8 A + Stroke 4-5.5 65 56 Rear flange

7 50 2B 50F 33 50 Flange Note 1) Only air operated style Table r Applicable pressure Pilot pressure Valve size 5 to 7 TL D DL Except for rated voltage 6, 7, 9. 4.2-12 VNB Model Weight (kg) Port size Orifice size (mm) Cv Flow rate Effective area (mm2) Air operated External pilot solenoid Model Flange(1) Rc(PT) 13 11 15 11 15 14 20 16 25 22 32 22 32 28 40 28 40 33 50 33 50 43 29 43 29

49 LS LS 89.2 23 33 79.2 89.2 10 to 50 75, 100 33 49 32 Rod end nut 38.5 Front flange type: CLQF32 54.2 48 34 8 4-5.5 65 56 17 32 B + Stroke A + Stroke Front flange type (mm) Stroke range Without auto switch With auto switch Bore size (mm) A B A B 82 23 33 72 82 10 to 50 75, 100 33 32 Rod end nut 38.5 Rear flange type: CLQG32 54.2 48 34 7 32 B + Stroke 8 A + Stroke 4-5.5 65 56 Rear flange