Series VER2000/4000 5 Port Electro-Pneumatic Proportional Valve How to Order Port size Nil Without sub-plate 02 03 1 4 3 8 ARJ VER2000 02 Series VER2000 AR425 to 935 AMR 03 0 VER400 Series VER4000 ARM Thread type Pilot type Internal pilot External pilot ARP 0 1 Nil Rc Port size F N G NPT T IR Nil Without sub-plate 03 04 06 3 8 1 2 3 4 NPTF IRV VEX1 SRH Note) To order valve with interface
PVPD 00 1 2 PVPD 03 0.3 0.35MPa 0.4MPa PVPD 04 0.4 0.35MPa 0.45MPa 3 05 0.5 0.35MPa 2) PV 06 0.6 0.5MPa 1) PD 3 0 1 PVPD PVPD PVPD PVPD K1 N.C. N.C. 2 J1 N.C. M5 Q1 +COM N.C.
"Line name communication data" Value (16 decimal 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) 7 seg Display digit 11 seg Value (16 decimal 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) 7 seg Display digit 11 seg Value (16 decimal 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) 7 seg Display digit 11 seg Remark The value of cannot be displayed -105No.PS-OMW0009
---I -~ _:_::-::: : ::-0.7ipa ~,,:-~~.'. "". 0~~1~00 ~~2~0~~~ ~ 0 30~0-4~OLO-~50~0~~60~0 0 1500 3000 4500 6000 7500 Air flow rate Qlmin (ANR) Air flow rate Qlmin (ANR) AMH350 AMH850 0.5MPa )7MPa I I // ",0.06I-Air pressure 0.3MPa '" 0.06 Inlel air pressure 0.3MPa / a. V o/pa ~pa ::;; a. V~V ::;; Q) /-Y :; ~0 . 04 '// ~ / /,/ ~ 0.04
Interchangeability Interchangeability The bodies and workpiece mountings are interchangeable between Series MY1M and MY1C. 8-11-2 3 27 Height 27 mm 40 High precision guide type MY1H10 Basic type MY1B10 30 20 MX MTS 10 MY 00 The stroke adjusting unit (H unit) does not protrude above the table type.
The part numbers have therefore changed from “IS3□1-02□” to “IS3□00-02□.”
Note) The ø10 electrical entry type of the IS300 series has been discontinued.
output style 16 OUT2 output mode / output style 17 Line name (left side 4 digits, right side 5 digits) 18 Display channel 19 CH1 measurement display value 20 CH2 measurement display value 21 CH3 measurement display value 22 CH4 measurement display value 23 Display OFF (No display) : Settable : Not settable (negative acknowledge) -94No.PS-OMW0012-C Value (16 Hex number) 00
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation
Wind mode lower side set value 12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -83No.PF-OMY0002 [Line name communication data] Value (16 hex number) 00
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles
01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -49No.PF-OMX0007-A Specifications Models PF3A701H PF3A702H Applicable fluid 1 Air, N2 Fluid Operating fluid temperature
mode/output style 16 Line name (left side 4 digits, right side 5 digits) 17 Display channel 18 CH1 measurement display value 19 CH2 measurement display value 20 CH3 measurement display value 21 CH4 measurement display value 22 Display OFF (No display) : Settable : Not settable (negative acknowledge) -87No.PF-OMA1011-A [Line name communication data] Value (16 Hex number) 00
Fig. 1 shows an internal alarm circuit of the IP8101-02(Non explosion protected construction). 11: 10mADC or more load current is needed to operate the main circuit of the internal switch, and it should be 40mADC or less to protect the internal resistance circuit. Therefore, use a power supply voltage and load resistance with a load current of 10 to 40mADC when the output is on.
Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32
Phone AUSTRIA / (43) 2262-62 280 ITALY / (39) 02-92711 BELGIUM / (32) 3-355 1464 NETHERLANDS / (31) 20-531 8 CZECH REP. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20 DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85 FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22 FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100 GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700 GREECE / (30)
Settings can be made from 00 to 99. Store the setting with the SET key.
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 3/4 PT, AIRLINE EQUIPMENT, AN SILENCER, GX, AN 3/4INCH (MISC./OTHER), .43422 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 3/4 PT, AIRLINE EQUIPMENT, AN SILENCER, GB, AN 3/4INCH STANDARD (PT), .48400 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 1-1/4 PT, AIRLINE EQUIPMENT, AN SILENCER, IB, AN 1 1/4INCH STANDARD (PT), 1.27720 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?