HRS Series 5.10Operation Restoration after Power Failure 5-27 HRX-OM-S004 Chapter 5 Display and setting of various functions 5.10.2 Setting/checking of the operation restoration function The table below shows the setting items of the operation restoration after power failure function and the default setting.
Input current calibration 26 Mode Change on LCD 27 Mode Change 27 No.IP8S-OM09 1 Parameter Mode Functioning in Manual Mode 27 Reflection of Changed Content in Parameter Mode 27 Auto Mode Operation 28 Auto Mode 28 Display Switching Method at Auto Mode 28 Manual Mode Operation 28 Setting Parameters 29 Parameter Code 29 Parameter Code Detail 30 How to Change Values 41 Parameter Setting Procedure
Input current calibration 26 Mode Change on LCD 27 No.DIG-31900-OM002 1 Mode Change 27 Parameter Functioning in Manual Mode 27 Reflection of Changed Content in Parameter Mode 27 Auto Mode Operation 28 Auto Mode 28 Display Switching Method in Auto Mode 28 Manual Mode Operation 28 Setting Parameters 29 Parameter Code 29 Parameter Code Detail 30 How to Change Values 39 Parameter Setting Procedure
3.1. . 12 3.2 . 13 3.3. . 14 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 Node Address/Data Rate . 18 4.2 . 19 4.3 DeviceNet . 19 1Step Data Class 67h . 19 2IO Class 68h . 20 3IO . 21 4IO . 21 5 . 23 5.1 PWR . 23 5.2 MOTENC . 23 5.3 SII/O . 23 1 . 23 2 . 24 5.4 DeviceNet . 24 6CN1: . 25 6.1 . 25 6.2 . 25 6.3 . 26 1(C24V,M24V,0V) . 26 2(EMG) . 26 3LK RLS . 26 1 - 6.4 . 27
(1) Test Drive setting . 27 (2) Change to Remote mode . 27 (3) Return to origin . 28 (4) Test drive starts . 28 3.9 EtherNet/IP communication setting and checking . 29 (1) Controller setting . 29 (2) PLC set up . 29 (3) LED Display . 29 3.10 Operation test by PLC . 29 4.
32 39 18 21 24 27 32 39 24 30 34 40 46 58 92 113.5 116.5 116.5 135 135 47.5 66.5 64.5 60.5 74.5 67.5 62 63.5 76.5 76.5 85 85 17.5 16.5 24.5 20.5 24.5 17.5 25, 50, 75, 100, 125, 150, 175, 200 Nil TN TF P Bore size (mm) PW Q R S T U V X YY YL Z MM ML NN OA OB OL 20 25 32 40 50 63 M5 x 0.8 M6 x 1 M8 x 1.25 M8 x 1.25 M10 x 1.5 M10 x 1.5 Rc1/8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 Rc1/4 17 18 26 27 28.5 30
18 SR3.5 26.6 3 18 M5 x 0.8 13 40 17 27 5 67.5 14.5 4-M4 x 0.7 Thread depth 7.5 2-M5 x 0.8 (Port size) 71.5 103 + Stroke 24 127 + Stroke 2 10-12-12 High Precision Stroke Reading Cylinder Non-rotating Piston Type Series CEP1 Foot style: CEP1L12 Stroke 4-4.5 (Positioning pin hole) 40 5.5 13 25 6 RE A B +0.05 +0.02 4 REC CX 66 54 CY MQQ M RHC MK(2) RS Q G 47.5 RS H A 17 RZQ 40 27 3.5 51 MI
Grommet terminal DIN terminal 2 to 10 Plug-in type VV5FR3-01(-Q) VFR300-F(-Q) 2 to 8 VFR31-E VFR31-D(-Q) VFR34-G VFR34-E VFR34-T VFR34-D(-Q) Non plug-in type VV5FR3-10(-Q) Note) 3 8 1 4, 1 2 Side/Bottom C8, C10 SJ 2 to 10 Grommet Grommet terminal Conduit terminal DIN terminal Non plug-in type VV5FR3-40(-Q) SY Note) If silencer is mounted to EA/EB port, use silencer AN403-04 (O.D. 27
Width across flats 27 14 34 14 34 2 x 5.5 Mounting hole 42 42 B B DIN terminal: D Conduit terminal: T 23 23 (E) G1/2 Cable 6 to 12 K I F I F 34 K D 32 J Width across flats G Width across flats G (E) 14 25 31.5 (44) E E 14 J (L) A (C) C A 2 x H Port size E (E) G1/2 2 x H Port size 2 x 5.3 Mounting hole Mounting hole 2 x 5.3 Width across flats 27 Width across flats 27 42 14 34 14 34 42 B B
(37) 5 (15) D-M9, D-M9V 0 15 27 (39) 5 (17) d L d L 8 D-F8 0 15 47 25 D-M9W, D-M9WV 0 15 27 (39) 5 (17) Dimensions by Mounting Style (1) (2) (3) (4) ( ): Denotes the values of D-A9V, D-M9V and D-M9WV.
Note 2) A R P N.C. 3 port PA N.C. 17-5-5 3 Series LV Manually Operated Series LVH P. 17-5-27 Integral Fitting Type Model LVH20 4 4, 6 1/8, 3/16, 1/4 LVH30 8 6, 8, 10 1/4, 3/8 LVH40 10 10, 12 3/8, 1/2 Orifice diameter Tubing O.D. Metric Inch Symbol Type Valve type Basic type N.C. A B A B Non-locking Locking Manifold (5 stations max.)
) 11(B port) (12.5) Indicator light Indicator light 167 181 59 73 50 90 108 2 4 24.6 38 48 11 (A port) 11 (B port) B A (12.5) (12.5) 14 12 1 5 3 4 2 Manual override 30 45 24.6 A B 25.6 Mounting hole 38 48 B A 14 5 3 1 12 30 45 25.6 Mounting hole Manual override 14.5 27 30.5 32 41.5 91.5 129 G1/2 Electrical entry 79 PE X 41.5 32 30.5 X PE 27 R1 R2 P 15.5 14.5 R1 R2 P 15.5 Rc1/8 External pilot
:Opfion' ,' Note Lead wire with connector zs-27-A Lead wire length: 2m Bracket zs-27-B With mounting screws lM3x5L:2Pcs.) Panel mounl adapter H i s h-p reci s io n D i s *"l?
(general purpose type) Dust-protected SI unit (L4) (L3) L2 (5.25) (12) 13 27 28 L1 Indicator light 63.5 10.5 (n-1) x 10.5 23.5 1.5 Manual override B A B A B A B A A A A FG + + 0V 24V SMC S E R I A L U N I T MODEL SC (SI No.EX120-STA1) 2 93.5 66 64 ERR T/R RUN (35) (5.5) 0 1 DIP SW. 4 x M4 mounting hole 61.5 4.5 Drawing shows a SC case.
25 22 27 52.3 45.9 Union Elbow: KFG2L Applicable tube size (mm) O.D.
ZS-27-C Panel mount adapter Panel mount adapter + Front protective cover With M3 x 8L (2 pcs.) ZS-27-D Note) These options are not attached in the factory, but packed together with it for shipment. Front protective cover 1 pc.
steel roller Hexagon nut thick 6, across flats 27 EXH port (3 port only) Panel mounting hole 3 port SA VA 0.5 MPa supply 3.5 mm P.T. 56 N F.O.F.
Width across flats 27 A A T T IN OUT IN OUT B B K L K L M 40 M 40 2 x P 1 (IN), 2 (OUT) port (50) (50) 2 x P 1 (IN), 2 (OUT) port DIN terminal: D Conduit terminal: T 19.5 53.5 65.5 19.5 34 (69.5) (100.5) 30 32 T Width across flats 27 Width across flats 27 31.5 (44) 25 Applications A A T G1/2 OUT IN OUT IN B B G1/2 K L K L M 40 40 M Cable 6 to 12 2 x P 1 (IN), 2 (OUT) port (50) (50) 2 x P
16 15 23.5 35.5 47.5 53.5 77.5 95.5 107.5 9 D-A7l/A80 10 10 10 17.5 29.5 41.5 3 16 9.5 9.5 18 30 42 48 72 90 102 3.5 D-A79W 10 7.5 15 27 39 0.5 16 7 15.5 27.5 39.5 45.5 69.5 87.5 99.5 1 : In the actual setting, adjust them after confirming the auto switch performance.
12.5 27 14.5 27 10.5 22 12(10.5) 22 13.5 22 6 29.5 16 29.5 18 29.5 14 24.5 15.5(14) 24.5 17 24.5 9.5 42 22.5 42 24.5 42 20.5 37 22(20.5) 37 23.5 37 16 The values inside ( ) are for D-Z73.