VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.
Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> S 5 % * ,* -> -/& 05 ( ! 001 # ) # ) #' ) L 5 % ) / *% ' 06 ! 002 003 Z 5 % *%+ * ,* -07 ( =+4 7> 08 (?
O-ring O, @, O Non plug-in type ME263LR-o2-1 Plug-in type Conneclor lead wires With terminal block. o @ End plate (kit) asJY ME272LR-02-1 End Plate (U) lD, End plate (D) (D ,Clamp O ' O o-rins G), O, O, O. Non plug-in type 1!
VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.
Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 Bore size (mm) LT LH L1 LG L LD L L1 B 36 46 43.5 53.5 53 63 LS 10 20 13.5 23.5 19 29 A B LS A 63 8 33.5 63 72.2 46 20 63 3.2 46 5 18 11 43.5 80 10 43.5 80 85 53.5 23.5 74.5 4.5 59 7 20 13 53.5 100 12 100 98 63 29 86 6 71 7 22 13 53.5 Flange bracket material: Carbon steel Foot bracket material: Carbon steel Bore size (mm
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LTF Light-weight, compact electric Light-weight, compact electric Frame-type linear guide has one-piece Frame-type linear guide has one-piece Space saving, light weight Space saving, light weight 50 40 46 33 60 74 LTF8 work piece mounting section
(7.5) 38.5 48 45.9 48 24 6.5 M4 x 0.7 thread depth 8 (F.G. terminal) 6 120 D x 120 (= E) B 10 35 3H9 ( ) depth 3 + 0.025 0 Motor mounting position: Left side parallel LEFS25L Motor mounting position: Right side parallel LEFS25R n x 4.5 4 48 106 106 46 46 47 47 (mm) Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to
Double solenoid V110N-D5MOZConnector assembly (for junction common) SJ3000-46-SC Single solenoid V110N-S5MOZConnector assembly (for junction common) SJ3000-46-DC Common wiring Connector assembly SJ3000-46-S (Example) VV100-10-04U1-C6 1 set V110N-S5MOZ-C4 2 sets V110N-D5MOZ-C4 2 sets SJ3000-46-S 1 set (Connector assembly for single solenoid) SJ3000-46-SC 1 set (Connector assembly for single
Check that a proper connection is established between the power cable and main breaker of this system. 02 Incorrect Phase Error FLT Stop The power phase rotation is wrong. The pressure of the refirigerant circuit exceeded the specified value.
NO YES Use With No Problem. 11
2-2 System Configuration 12
2-3 Recommended Circuit Design Horizontal Mounting Downward Mounting Upward Mounting
YES NO NO 2 YES YES NO NO YES 10 2-2 (CEU2) (AC100V,15) (24V10,0.4A) (0.3MPa0.5MPa) 3) () (CE1-R**) (CE2**) 11 2-3 40 VFS240R VFS210 AR425 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 12/9 AN300-03 AS4000-03 80 VFS440R VFS310 AR425 12/9 AN300-03 AS420-03 100 VFS440R VFS310 AR425 12/9 AN400-04 AS420-04 12 * 3. 3-1 () 40 50 63 80
Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12
load No load Load ratio Load ratio Bore size (mm) Bore size (mm) AS4000-02/03/04 AS3000-02/03 Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Circuit diagram No load No load Load ratio Load ratio Speed controller Bore size (mm) Bore size (mm) 10-17-12 Product Profile: Hydraulic Cylinders: Series CH For details, refer to the catalog CAT.
LVA LVH Connection 1 4 3 8 1 2 3 4 02 03 04 06 10 LVD Thread type Nil T F N Refer to the table (2) given below for availability. Rc NPTF G NPT Thread LVQ Refer to page 17-3-16 for ordering coil only. 1 LQ 32 40 50 For 32A For 40A For 50A Flange LVN Refer to the table (1) given below for availability.
LVH Connection LVD 02 03 04 06 10 12 14 20 1 4 Thread type Nil T F N Refer to the table (2) given below for availability. 3 8 1 2 3 4 Rc NPTF G NPT Thread LVQ Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LQ 1 4 1 2 LVN 32 40 50 For 32A For 40A For 50A Flange TI/ TIL PA Refer to the table (1) given below for availability.
Used beyond the specifications of Use within the range of specifications. close mounting. 46 Servo motor overheat Servo motor temperature rise actuated the thermal sensor. 1. Ambient temperature of servo motor Check environment so that ambient temperature is 0 to 40 . is over 40 . 2. Servo motor is overloaded. 1. Reduce load. 2. Check operation pattern. 3.
AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.
AW-OMZ0062 PRODUCT NAME icro Mist Separator Regulator MODEL / Series / Product Number AWD20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWD30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWD40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3.
selection mode 25 Default setting 25 F 0 Display units, switch output specifications and diagnostic information selection function 27 F 1 Setting of OUT1 29 F 2 Setting of OUT2 32 F 3 Digital filter setting 34 F 4 Auto-preset function 35 F 6 Fine adjustment of display value 37 F10 Sub display setting 38 F11 Display resolution setting 44 F14 Zero cut-off setting 45 F80 Power saving mode 46
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46