L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
Symbol AMD 4.6-7 Micro Mist Separator Series AMD AMD150 to AMD850 How to Order AMD 250 03 J B Body size Options J Drain guide 1/4B female thread R IN R OUT reversal 150 1 8 250 1 4 350 3 8 450 1 2 550 3 4 650 1 850 11 2 Accessories(Options) Symbol Description None Bracket T Element service indicator B N.C. auto drain C N.O. auto drain D Please refer to p.4.7-7 regarding How to Order of case
(variations on the order of 30%) Large variations may occur depending on the surrounding environment.
(variations on the order of 30%) Large variations may occur depending on the surrounding environment.
(variations on the order of 30%) Large variations may occur depending on the surrounding environment.
AXT661-14ALead wire length VZ AXT661-13ALatching VQZ100 VQZ100-GS-2 300mm 600mm 1000mm 2000mm 3000mm VQZ200 6 10 20 30 VQZ200-GS-2 VT DC (-COM) VQZ300 VQZ300-GS-2 AXT661-13ANLatching Note) Above part number consists of a 10 pcs. units with one gasket and two screws. Orders are accepted in 10 pcs. units.
, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-REA63 63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.
, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20 16 50 78 162 M10 38 77 19 63 16.5 16.5 13.5 6.5 16.5 Bore size (mm) J K L MM ML NN OA OB OL P PA PB PW Q R S T U VA 18 M8 x 1.25 7.5 M8 x 1.25 27 27 40 20 6.6 11 1/8 38 30 104 44 118 86 106 40 13 21.5 9 M10 x 1.5 9 32 32 46 22 8.6 14 1/4 47 40 130 60 146 110 130 50 M10 x 1.5 14 28 39 39 58 22 8.6 14 1/4 55 50 130 70
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
No.EX-OMN0029CN-D TMSI DeviceNet // EX600-SDN#A EX600-ED# 3 9 10 12 12 15 15 17 SI 18 18 19 19 20 LED 25 27 27 28 29 29 30 30 31 31 31 -1No.EX-OMN0029CN-D 33 34 43 43 54 EDS 54 TM 55 RSNetWorx for DeviceNet 59 60 63 TM 65 DeviceNet 77 -2No.EX-OMN0029CN-D *1) (ISO/IEC)(JIS) *2) *1) ISO 4414 Pneumatic fluid power -General rules relating to systems ISO 4413
These default values can be changed in the Offset FB Overall Accuracy +/5% (0.5V DC) Input Impedance 150 kOhm or higher Input Voltage 0 10V DC Conversion Speed 10 ms Resolution 10/250 mv Analog Input Range 0 250 ECC-PNAL-20M*-D 8 Channels: I01 I08 ECC-PNAL-10M*-D 6 Channels: I01 I06 Description Analog Input Specication 7 2.4 Output Specication PneuAlpha Hardware Specification 2 Table 2.7
L dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300/150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: D (Double Clevis), Bore Size: 40mm, Thread: TF (G Thread), Full Stroke: 50mm, First Stroke: 20mm
Mounting: D (Double Clevis), Bore Size: 40mm, Thread: TF (G Thread), Full Stroke: 300mm, First Stroke: 150mm
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300/150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Mounting: Double Clevis, Bore Size: 40mm, Thread: G Thread, Full Stroke: 50mm, First Stroke: 20mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
L1 L2 L3 L4 L5 L6 L7 (1) L8 D Model Bore size ASV AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 5 17 54.5 16 15.5 50 30 10 4.5 AK 1 4 1 4 2 x M4 x 0.7 11.5 17 56 51.5 40 5 23 20 30 4.5 Effective thread depth 6 Reference dimensions 8 3 45.5 5.25 20.6 61 13.2 68 56 25 26 5.5 VCHC Note 1) L7: Reference dimensions Dimensions: AS5000 ASR ASQ 2 x 1/4 to 1/2 2-1/4 to 1/2 74.9 (Max. 82.9)
If using an input voltage exceeding 125 VAC, select 02 (Without AC cord) and prepare a suitable AC cord separately. *3 This nozzle is complaint with the OSHA standard for hand and portable powered tools and equipment, general (1910.242b) requiring that static pressure at the main orifice shall not exceed 30 psi (210 kPa).
---I -~ _:_::-::: : ::-0.7ipa ~,,:-~~.'. "". 0~~1~00 ~~2~0~~~ ~ 0 30~0-4~OLO-~50~0~~60~0 0 1500 3000 4500 6000 7500 Air flow rate Qlmin (ANR) Air flow rate Qlmin (ANR) AMH350 AMH850 0.5MPa )7MPa I I // ",0.06I-Air pressure 0.3MPa '" 0.06 Inlel air pressure 0.3MPa / a. V o/pa ~pa ::;; a. V~V ::;; Q) /-Y :; ~0 . 04 '// ~ / /,/ ~ 0.04