Lock-Up Valve IL201/211/220 Series The lock-up valve is used if any air source or air supply piping line failure occurs in the air operated process control line. Single acting, Double acting: Retains pressure at the operating area as emergency operation until the air source is recovered to its normal state. 3 Port: Changes the supply port if a trouble occurs.
6 Stepper motor D 24VDC Input/Output type Function A Photo coupler input C Position control/Driver Motor type 220 2 phase motor (2A/phase) Applicable Actuators Built-in position control function added to LC6D Up to 28 patterns of movement data can be set.
Optional specification Note 2) With barb fitting B With drain guide B Metal bowl B 85 123 166 166 200 200 276 292 293 Metal bowl with level gauge Model B AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 161 161 195 195 272 287 288 160 160 194 194 271 286 287 186 186 220 220 296 312 313 4 F.R.L.
OFF Full step ON Half step 1 Set Release 2 Function change-over switch 308 Series LC6C Positioning driver Series LX Dedicated How to Order LC 6 C 220 A D Applicable motor Power supply 6 Stepper motor D 24VDC Input/Output type Function A Photo coupler input C Position control/Driver Motor type 220 2 phase motor (2A/phase) Applicable Actuators Built-in position control function added to LC6D
Vacuum pressure switch suction filter Voltage (Refer to Table 1.) 1 2 3 4 5 6 100 V AC 200 V AC 110 V AC 220 V AC 24 V DC 12 V DC Suction filter only 1 NPN output and analog output, suction filter 2 NPN outputs, suction filter 1 PNP output and analog output, suction filter 2 PNP outputs, suction filter F D31 D32 D51 Electrical entry D52 L plug connector, With 0.3 m lead wire With indicator
Atmospheric vent port Displayed when supply pressure is not in the range 80 kPa to 220 kPa. Measurement is not possible.
Name Main display Description Measures Pressure exceeding 220 kPa is supplied. Supply pressure error (When pressure value is displayed in the sub screen) Keep the supply pressure within the displayable range of -22 kPa to 220 kPa. Operation Vacuum pressure (-22 kPa or less) is supplied.
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Valve type Port size Rated voltage Valve size 3 2 1 100 VAC 50/60 Hz Symbol Nil: Non-locking push type Orifice size (mm) Symbol Port size Rc 1 2 3 Note) 4 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Symbol N.C. 1 MPa N.C. 0.5 MPa N.O. C.O.
VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage suppressor With light/surge voltage suppressor With indicator light Option VDW L Light/Surge voltage suppressor Nil Z VQ Except 12 VDC, 240 VAC, other voltages.
Vacuum pressure switch suction filter Voltage (Refer to Table (1).) 1 2 3 4 5 6 100 V AC 200 V AC 110 V AC 220 V AC 24 V DC 12 V DC Suction filter only 1 NPN output and analog output, suction filter 2 NPN outputs, suction filter 1 PNP output and analog output, suction filter 2 PNP outputs, suction filter F D31 D32 D51 Electrical entry D52 L plug connector, With 0.3 m lead wire With light/
VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages, please consult with SMC.
03 AMH250-03 AMH250-03 AMH350-04 AMH350-04 AMH450-06 AMH550-10 AMH550-10 AMH650-14 AMH850-20 AM850-20 AMH850-20 IDG20-03 IDG30-03 IDG50-03 IDG75-04 IDG100-04 IDF2D-1 IDF3DIDF4DIDF6DIDF8DIDF11CIDF15CIDF22C1-3 IDF37C1-3 IDF55C-3 IDF75D-3 IDF120D-3 IDF150D-3 IDF240D-3 IDF55C-3 AM850-20 AMD850-20 75 AMF1000-40 AMF900-30 AMF850-20 AMD850-20 AMD910-30 AMD910-40 AMD1010-40 IDF120D-3 110 150 220
60 76 110 102 136 184 44 66 96 9 11 13 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AME550 AME650 AME850 1 2 1 2 1 2 1 Please refer to page 14-20-57 for Made to Order Specifications. 14-20-41
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 1 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMH850 1 2 13 42 348 220 57.5 220 10 Please refer to Made to Order Specifications of Series AMH on pages 14-20-55 to 14-20-57. 14-20-35
How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
CN I/F is approx. 10mA GND 1 4 AM26LS31 equivalent Shielding wires 3.9k 1 2 22 23 24 25 COM+ CW+ CW CCW+ CW pulse input Servo ON input Switch ON turns servo ON 220 SRV-ON GAIN Switch ON selects secondary gain 5 Gain switching input CCW pulse input 220 CL CCW 4 Deviation counter clear input Command divider multiplication switching input 3.9k Switch ON selects secondary multiplication 6 3
60 76 110 102 136 184 4.5 4.5 6 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AME550 AME650 AME850 AME450SAME, #4 AME550SAME, #5 AME650SAME, #6 AME850SAME, #7 4.6-26
Standard specifications AL30 AL40 AL60 AL10 AL40-06 AL20 AL50 Model Port sizes 1/4, 3/8 1/4, 3/8, 1/2 1 M5 x 0.8 3/4 1/8, 1/4 3/4, 1 Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa 1/4: 30 3/8: 40 1/2: 50 Note 1) 1/4: 30 3/8: 40 220 4 50 15 190 Minimum dripping flow rate [L/min (ANR)] Oil capacity (cm3) 55 135 7 135 25 135 135 Recommended lubricant Class 1 turbine oil (ISO