or less Switch Output NPN or PNP open collector OUT1: General-purposeOUT2: Valve control Maximum load current 80 mA Max. applied voltage DC26.4 V Residual voltage Max. 2 V (at 80 mA load current) Response time 2.5 ms or less (response times available for anti-chattering function: 20, 100, 500, 1000 or 2000 ms) Short circuit protection Provided Repeatability 0.2%F.S.1 digit Hysteresis Hysteresis
Product failure Replace the product -90No.PF-OMY0005-A Error indication Problem Possible causes Investigation method Countermeasure (1) Check if the output current is 80 mA or greater. (1)(2) Connect the appropriate load. (2) Check if the connected load complies with the specification.
Table 3-4 Power supply cable and Earth Leakage Breaker(Recommended) Termin Earth leakage breaker *1 al Recomm Model Power supply block ended Cable qty. x Sensitivity Rated voltage size*2 screw crimp of leak current current terminal diamet [A] [mA] er 4 cores x AWG10 3phase HRS100-A-2030 R5.5-5 (4 cores x 5.5mm2) 200VAC(50Hz) HRS100-W-20*including ground 3phase 4 cores x AWG8 HRS150-A-20200
To use the power from the device, the total load current must be 200 mA or less. 2:Refer to 3.3.6 Wiring of the contact output signal HRL Series 3.3 Installation 3-19 HRX-OM-X037 Chapter 3 Transport and Setting Up Table 3.3-4 Contact input/output communicatin /Analog output pin number PIN No.
mA Internal voltage drop 0.8 V or less at load current of 10 mA (2 V or less at load current of 40 mA) 4 V or less Current leakage 100 A or less at 24 VDC 0.8 mA or less Indication light Operating position: The red LED lights up.
D-F6N D-F6P D-F6B Wiring type 3-wire type 2-wire type Output type NPN PNP Applicable load IC circuit / relay / PLC 24 VDC relay / PLC Power supply voltage 5/12/24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA load current (2 V or less at 40 mA load
40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at load current of 10 mA (2 V or less at load current of 40 mA) 4 V or less Current leakage 100 A or less at 24 VDC 0.8 mA or less Indication light Operating position: The red LED lights up.
Model Wiring NPN transistor (open collector output) CEU5 50 mA or OUT less CEU5B Load Power CEU5-D COM (30VDC or less) CEU5B-D PNP transistor (open collector output) CEU5P (50 mA or less) OUT CEU5PB Load Power CEU5P-D COM (30VDC or less) CEU5PB-D 6-5.
. -25 NPN open collector output Max.30 V, 80 mA Residual voltage 1 V or less -65 PNP open collector output Max.80 mA Residual voltage 1 V or less -10No.PS-OMJ0004-E Pressure Setting Operation When the pressure exceeds the set value, the switch will be turned ON. When the pressure falls below the set value by amount of hysteresis or more, the switch will be turned OFF.
Model ZK2-ZSV-A Rated pressure range -100 to 100 kPa Set/Display pressure range -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less NPN or PNP open collector Output type OUT1: General purpose, OUT2: Valve control Maximum load current 80 mA
Model ZK2-ZSV-A Rated pressure range -100 to 100 kPa Set/Display pressure range -105 to 105 kPa Proof pressure 500 kPa Minimum setting unit 0.1 kPa 12 to 24 VDC 10%, Ripple (P-P) 10% or less Power supply voltage (Protected against reverse connection) Current consumption 40 mA or less NPN or PNP open collector Output type OUT1: General purpose, OUT2: Valve control Maximum load current 80 mA
MHC MHT MHY MHY Max. tightening torque (Nm) Model Applicable bolts MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 1.4 2.5 4.1 10.6 24.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 MHW MHW -X MRHQ MA D723
180 Angular Type Air Gripper MHY2/MHW2 Series 10, 16, 20, 25 MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHY MHW MHW -X MRHQ MA D697 180 Angular Type Air Gripper MHY2/MHW2 Series Cam Type Rack & Pinion Type MHY2 Series/Cam Type Light and compact size in small bore sizes Over length L (mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHY2-10D 10 0.16 70 71 MHY2-16D 16 150 0.54 84 MHY2-20D
48 VAC, DC: 40 mA 100 VAC, DC: 20 mA Non plug-in type Note 1) Combining valve VFR41 (single) and release valve spacer makes it possible to use this as an air release valve.
48 VAC/DC: 40 mA 100 VAC/DC: 20 mA VS4 Max. switch capacity Note 1) Voltage: 24 VDC to 100 VAC Inner voltage drop: 4 V Note 2) Combination of a valve VFS41 (single) and a release valve spacer can be used as an air release valve.
Mass Output Indicator light Current consumption Operating temperature range Max. operating pressure 50 g Open collector 30 V, 80 mA ZM Light at ON state 17 mA or less (24 VDC, at ON state) ZMA 0 to 60C 0.5 MPa ZQ Sensor chip When using ejector system, instantaneous pressure up to 0.5 MPa will not damage the switch.
3 rotations 200 degrees 200 degrees 25 mA or less (When 24 VDC is ON) 16 mA 0.5 MPa 5 to 20 mA Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.2 MPa When using ejector system, instantaneous pressure up to 0.5 MPa will not damage the switch.
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
or less 170 mA or less 290 g 150 mA or less 250 g 1/8, 1/4 3/8 1/2 Heater type 3-digit, 7-segment LED 50 kPa to 0.75 MPa 50 kPa to 0.5 MPa 1.0 MPa 0 to 9 l NPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputs Resistance Output specifications Note 5) Switch output PNP open collector Maximum