TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input signal 1: Run/Stop (Default setting) 4.7 k 1 k 3 Contact input
48 VAC, DC or less: 40 mA 100 VAC, DC or less: 20 mA Center of F.R.L. body D A P * For detailed specifications of the IS10 series, refer to the IS10 series section on the SMC website: https://www.smcworld.com Model P A B C D Applicable AC size IS10T-20-D 1/8, 1/4 28 77.6 60.1 42 AC20-D IS10T-30-D 1/8, 1/4, 3/8 31 85.6 64.1 53 AC30-D IS10T-40-D 1/4, 3/8, 1/2 39 93.6 68.1 71 AC40-D IS10T-
), 0.95 W DC (40 mA) Note 3) 24 VDC 3-position exhaust center 0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3) 12 VDC Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA) 100 VAC Power consumption (Current) Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA) 3-position pressure center 110 VAC Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA) 200 VAC Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA) 220 VAC Note 1)
5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC Note 1) Use dry air to prevent condensation when operating at low temperatures.
), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC
) 100 VAC 0.5 VA (5 mA) Power consumption 0.65 VA (5.9 mA) 110 VAC 0.55 VA (5 mA) (current value) 1.2 VA (6 mA) 200 VAC 1.0 VA (5 mA) 1.3 VA (5.9 mA) 220 VAC 1.1 VA (5 mA) L plug connector Grommet Grommet L plug connector With light/surge voltage suppressor L plug connector (With light/surge voltage suppressor) ( ) Electrical entry With light/surge voltage suppressor Vacuum Pressure Switch
Output Specifications 25 (L) 1 output NPN open collector 30 V, 80 mA or less Analog output (1 to 5 V) ZSE4 ZSE4B 26 (L) 67 (L) 1 output PNP open collector 80 mA or less 26 (L) Analog output (1 to 5 V) ZSE4E 27 (L) 2 outputs NPN open collector 30 V, 80 mA or less 67 (L) 2 outputs PNP open collector 80 mA or less 13-3-16 16 Series ZR Large Size Vacuum Module: Ejector System ZX ZR ZM ZH ZU Courtesy
SMC website: https://www.smcworld.com 172 a JXCE1/91/P1/D1/L1/M1 Series Specifications Model JXCE1 JXC91 JXCP1 JXCD1 JXCL1 JXCM1 Network EtherCAT EtherNet/IP PROFINET DeviceNet IO-Link CC-Link Compatible motor Step motor (Servo/24 VDC) Power supply Power voltage: 24 VDC 10% Current consumption (Controller) 200 mA or less 130 mA or less 200 mA or less 100 mA or less 100 mA or less 100 mA
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. +V CEP1 Internal circuit 3. Output circuit There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
Flat w~h rib (mm) Model . .A .8 C JD ' Model 'A .8 C D E F I:M6x1 I:Ma XI y I I: Ma x l Y E F I r.M6 Xl G c H G H ..JatlFlat1>ilt1 rib I . .
The voltage and the amperage capacity of the switch or the PLC to be connected are 24 VDC, 10 mA or higher. Internal circuit RE A B REC 3. Output circuit CX There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
Slide bearing Ball bushing bearing M L M 80 50 Y7BW MVGQ Cylinder 1 0 5 L 4 MA VF3 Valve Speed controller specifications Type of actuation 2 position single solenoid 2 position double solenoid 1 2 MA MB Meter-out Meter-in Option Please consult with SMC for 3 position type.
Mr = 0.2 x 9.8 (20 + 6.8)/1000 = 0.053 Ma = Mmax Find the allowable static moment Ma (Nm).
30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
() DC15 V(1 M) 1 (26.4 V ) NPN PNP 2 80 mA DC30 V(NPN ) 1 V (80 mA ) () 100 ms.500 ms1 s2 s 15 V( 1 k () (25 ) 1F.S. 420 mA() 600 (DC24 V) 50 () (25 ) 1F.S
*1: To use the power of the device, the total load current must be 500 mA or less.
or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal
or less Data Weight 45 g Maximum load current: 80 mA NPN open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301