Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
or less 170 mA or less 290 g 150 mA or less 250 g 1/8, 1/4 3/8 1/2 Heater type 3-digit, 7-segment LED 50 kPa to 0.75 MPa 50 kPa to 0.5 MPa 1.0 MPa 0 to 9 l NPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputs Resistance Output specifications Note 5) Switch output PNP open collector Maximum
48 VAC/DC: 40 mA 100 VAC/DC: 20 mA Max. switch capacity Note 1) Voltage: 24 VDC to 100 VAC Inner voltage drop: 4 V Note 2) Combination of a valve VFS41 (single) and a release valve spacer can be used as an air release valve.
Note 2) For interface use, supply 24 VDC o10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions.
or less Switch Output NPN or PNP open collector OUT1: General-purposeOUT2: Valve control Maximum load current 80 mA Max. applied voltage DC26.4 V Residual voltage Max. 2 V (at 80 mA load current) Response time 2.5 ms or less (response times available for anti-chattering function: 20, 100, 500, 1000 or 2000 ms) Short circuit protection Provided Repeatability 0.2%F.S.1 digit Hysteresis Hysteresis
MA B Auto switch mounting heights D-A9V D-F9V D-F9WV (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL MA MA MA 20 25 25 27 25 27 27.5 29.5 A Approx.
MA B D-A9V D-F9V D-F9WV Auto switch mounting heights (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL SMC D-A90V SMC D-A90V MA MA MA 20 25 25.5 27.5 25.5 27.5 28 30 A Approx.
Connector pin numbers -18No.PS-OMS0007-H Internal circuit and wiring examples Z/ISE20(F)---Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage: 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage: 1 V or less -19No.PS-OMS0007-H Outline of Settings [Measurement mode] Power is supplied.
Table 3-4 Power supply cable and Earth Leakage Breaker(Recommended) Earth leakage Terminal Recomm breaker *1 Model Power supply block ended Cable qty. x Sensitivity Rated voltage size*2 screw crimp of leak current current diameter terminal [A] [mA] 3phase 200VAC(50Hz) HRS090-A-2030 3phase HRS090-W-20200 to 230VAC (60Hz) 3phase HRS090-A-404 cores x AWG10 380 to 415VAC 30 HRS090-W-40M5 R5.5
External switch signal Current consumption: 5 mA or less Max. load current: 40 mA Max. load current: 40 mA Discharge signal Residual voltage: 1 V or less Residual voltage: 1 V or less Error signal Output signal (with load current of 40 mA) (with load current of 40 mA) Max. applied voltage: DC 28 V Maintenance signal Effective charge eliminating distance 20~500 mm 0~55oC Ambient temp.
(at 24 VDC) Input OFF voltage/input OFF current 5 V or less/1.5 mA or less (at 24 VDC) Rated input current Approx. 7 mA Internal current consumption 200 mA or less (when the input signal is ON) Display Green LED (Lights when ON) Sensor connector EX500-DXPA: M8 connector (3 pin, socket) EX500-DXPB: M12 connector (5 pin, socket) Short circuit protection Available Enclosure rating IP67 Body
Specifications Table 12-1 EX245-DY1 specifications Item Description General Dimensions (W x L x H) in mm 54 x 120 x 61 Weight 280 g or less Housing material Nylon, PBT Electrical Rated supply voltage 24 V DC Voltage drop to load supply Max. 1.6 V Internal current consumption at 24 V DC 50 mA or less Load connection 4 x M12, 5-way sockets with double allocation Over Voltage protection Yes,
Table 11-1 EX245-DX1 (W x L x H) mm 54 x 120 x 61 280g , PBT 24 V DC 1.6 V 50 mA 8 x M125 A code 2 / US1 30V /1 0.5A /1 2 A 1 16 PNP ON 11 to 30 V OFF -3 to 5 V 1.5mA ON Typ. 4.5 mA 24VDC 71 No.EX##-OMY0006CN 11.3. /SI IP65M12 M12,5 , Table 11-2 EX245-DX1 (TOP View) 1 24 V 2 2 DI ( n+1) 3 5 1 3 0 V (US1) 4 DI (n) 4 5 FE/ 11.4.
Tighten the connector by hand. -23No.PF-OMV0006-B Examples of Internal Circuit and Wiring NPN output type Max.28 V, 80 mA Internal voltage drop 1 V or less PNP output type Max.80 mA Internal voltage drop 1.5 V or less Used as IO-Link device : Numbers in the figures show the connector pin layout.
Prepare the switch (power supply voltage: 24 VDC, contact capacity: 35 mA or more, minimum load current: 5mA) and suitable connector cable. HRS Series 3.3 Installation 3-21 DOC1001322 Chapter 3 Transport and Setting Up 2. Wire the contact input / output signal connector as follows and connect it to this product.
To use the power from the device, the total load current must be 200 mA or less. 2:Refer to 3.3.6 Wiring of the contact output signal 3.3 Installation HRL Series 3-18 HRX-OM-Y098 Chapter 3 Transport and Setting Up Table 3.3-4 Contact input/output communicatin /Analog output pin number PIN No.
no (M ma mTNN ALNN Alarm number (Alarm number maximum FLOW / / / PUmP Pump output setting (%) 900 Displays only when the alam is generated.
The default setting is OFF. 12. 4-20 mA mode When the operation (Target position operation) where the cylinder is operation by input current (4-20mA) is performed, set the Operation mode (Menu Tree No.1-3-5-2) to 4-20mA. Refer to 7-3. Target Position Operation for the signal input method. 13.
Two wire sensor connection Possible Logic0allowable current IL Max. 2.5 mA Input delay time 3 msec.
(at 24 VDC) Input OFF voltage/input OFF current 5 V or less/1.5 mA or less (at 24 VDC) Rated input current Approx. 7 mA Internal current consumption 200 mA or less (when the input signal is ON) Display Green LED (Lights when ON) Sensor connector EX500-DXPA: M8 connector (3 pin, socket) EX500-DXPB: M12 connector (5 pin, socket) Short circuit protection Available Enclosure rating IP67 Body