L 1000 mm 2000 mm 3000 mm 4000 mm 5000 mm 7000 mm 10 mm IZS31-CF01-X210 IZS31-CF02-X210 IZS31-CF03-X210 IZS31-CF04-X210 IZS31-CF05-X210 IZS31-CF07-X210 IZS31-CF10-X210 Connection cable from the right-hand side of the control unit Frequency selection switch 12P modular jack (Plug for power cable) 190 36 16 30 Order connection cables separately.
6000 psig (41.4 MPa) inlet 1500 psig (10.3 MPa) inlet Inlet pressure: 3000 psig (20.7 MPa) inlet 4000 27.6 3500 24.1 1/4-20 UNC Screw For Panel Mounting Delivery pressure (MPa) Delivery pressure (psig) 20.7 3000 Max. 0.25 (6.4) Panel Thickness 17.2 2500 2000 13.8 To 6.88 (174.7) 1500 10.3 1000 6.9 500 3.4 0.75 (19.1) 0.50 (12.7) 3.84 (97.5) Min. 1.50 (38.1) 0 0.0 0 1000 2000 3000 4000 5000
0 1000 2000 3000 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) AR50(K)-B Rc1 AR60(K)-B Rc1 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 5000 10 0 0 0 5000 10 Flow rate L/min (ANR) Flow rate L/min (ANR) 68 Series AR10-A Series AR20-B to AR60-B Series AR20K-B to AR60K-B Pressure Characteristics (Representative
MPa 1.0 MPa ALIP Operating pressure differential range (Difference between tank pressure and line pressure) (Note 1) 0.1 to 0.6 MPa AEP HEP Vibration resistance (Pressure differential 0.3 MPa) 1 G (9.81 m/sec2) or less 120 : 65 : 100 : 120 190 220 1800 4 1 (Note 2) 4 1 Min. operating flow (L/min (ANR)) 8 3 1 : 460 1 : 650 2 1 2 1 (Note 3) Bowl capacity (cm 3) (Capacity between levels) 5000
0.007 to 0.2 MPa) AP1010 2 to 100 psig (0.014 to 0.7 MPa) Select compatible materials of construction for the gas AP1006 2 to 60 psig (0.014 to 0.4 MPa) AP1015 5 to 150 psig (0.034 to 1.0 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Vacuum to 3500 psig (24.1 MPa) 1) Vacuum to 300 psig (2.1MPa) 5000
0 1000 2000 3000 500 1000 1500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AR50(K)-B Rc1 AR60(K)-B Rc1 0.6 0.6 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 5000 10 0 0 0 5000 10 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 70 AR10-A Series AR20-B to AR60-B Series AR20K-B to AR60K-B Series Pressure Characteristics (Representative
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 526 Series AS Speed Controller: Standard Type In-line Type Needle Valve/Flow Characteristics Note) The flow characteristics are representative values.
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A AS Series Speed Controller: Standard Type In-line Type Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
~er ~ Zone 10 Distance From Auto Switch Top Face 0 5000 10 15000 20 Welding Current CAl .. ... i1 SO >. . /" /. 40 Sai. Zone ..
Symbol Model Remarks M9NJL D-M9NJL Lead wire length 3000 mm M9NJZ D-M9NJZ Lead wire length 5000 mm M9PJL D-M9PJL Lead wire length 3000 mm M9PJZ D-M9PJZ Lead wire length 5000 mm M9J/ Without auto switch (with magnet) y Number of auto switches/Mounting position Symbol Quantity Mounting position A 2 Valve open/closed B 1 Valve open C 1 Valve closed * For details about auto switches, refer to
Symbol Model Remarks M9NJL D-M9NJL Lead wire length 3000 mm M9NJZ D-M9NJZ Lead wire length 5000 mm M9PJL D-M9PJL Lead wire length 3000 mm M9PJZ D-M9PJZ Lead wire length 5000 mm M9J/ Without auto switch (with magnet) y Number of auto switches/Mounting position Symbol Quantity Mounting position A 2 Valve open/closed B 1 Valve open C 1 Valve closed * For details about auto switches, refer to
Standard Strokes Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 16 100,200,300,400,500,600,700,800,900 1000,1200,1400,1600,1800,2000 3000 25, 40 5000 Strokes are manufacturable in 1mm increments, up to the maximum stroke. When exceeding a 2000mm stroke, specify "-XB11" at the end of the model number. Refer to the Made to Order Specifications on page 33.
Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves. Available protocols include, but are not limited to DeviceNet™, PROFIBUS-DP®, CC-Link, and AS-i.
Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves.
Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves. Available protocols include, but are not limited to DeviceNet™, CC-Link, and AS-i.
Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves. Available protocols include, but are not limited to DeviceNet™, CC-Link, and AS-i.
(Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
(Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
(Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)