SMC Corporation of America
Elite Part Number Search
Search Results "LEFG40-S-1200"

MY3M Shock Absorber Specifications Piston Speed 16 to 100 10 Bore size (mm) RB 0806 RB 1412 RB 2015 RB 1007 RB 0805 Model Without stroke adjusting unit 100 to 500 mm/s 100 to 1000 mm/s 100 to 1500 mm/s (2) A unit 2.9 19.6 58.8 5.9 100 to 200 mm/s 1.0 100 to 1000 mm/s (1) Max. energy absorption (J) Stroke adjusting unit L unit and H unit 6 12 15 7 Stroke absorption (mm) 100 to 1000 mm/s 5

MI W S + 0.05 0.02 CEP1 CE1 CE2 ML2B C J G5-S Tolerances can be set with the preset value. OK/NG signal is output by the counter. Labor savings can be realized in parts inspections.

P Panel mount union U Union Ordering Example OUT side Tube size 4 x 3 LQ1U22-S Union SMC PB1313AS-1S07 Process pump PB1313AS-1S07 1 LQ1E21-S (Union elbow) 1 LQ1U22-S (Union) 1 LQ1E21-S Union elbow Tube size 6 x 4 Note) Fittings ordered together with the process pump will be shipped in a separate package.

(15 to 35C) 5% F .S. (0 to 50C) 2% F .S.

T U 8F7 +0.013 +0.028 through 11 through 5 16 30 0.025 30 0.025 30 0.025 30 0.025 30 0.025 30 0.025 30 0.025 30 0.025 30 0.025 V W X R40 45 155 0.05 M10 x 1.5 1 16 1 R37 30 10.5 R9 30 26 NAAMS code Weight kg (lbs) A B C D E F G H I J K L M N O P Q R S T U V W X Part no.

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

Symbol 40, 50 40 50 40 50 63, 80 100, 125 A14 A14N A14F A16 A16N A16F B8 B10 B12 B16 Rc1/8 NPT1/8 NPFT1/8 Rc1/8 NPT1/8 NPFT1/8 M8 x 1.25 M10 x 1.5 M12 x 1.75 M16 x 1.5 63 63 M14 x 1 80 80 Male thread 100 100 Mounting 125 125 M16 x 1.5 Pad type Female thread H Heavy duty Material N S NBR Silicon rubber Urethane rubber Fluororubber U F E EPR 1190 Series ZPT Vacuum Pad: Large/Heavy Duty Type

Ex.When inputting pushing speed of 20mm/s to RWwn+7 and 100% to positioning force. Pushing speed 20mm/s is 14h in hexadecimal. Positioning force data is expressed by 10%. The value to express 100% is 10, and 0Ah in hexadecimal.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size

Kinematic viscosity [m2/s] = Viscosity [Pas]/Density [kg/m3] 1 cP = 1 mPas = 10-3Pas 1 cSt = 1 mm2/s = 10-6m2/s 591 PB1313A Series Working Principle: Air Operated When air is supplied with the external 3-port solenoid valve turned ON (energized), air enters the driving chamber and the diaphragm moves to the left.

-S; LECSA2-S; LECSB1-S; LECSB2-S; LECSC1-S; LECSC2-S; LECSS1-S; LECSS2-S; 6: The motor and encoder cables are included.

Extension locking Retraction locking 100 100 63 63 50 50 40 Load mass kg Load mass kg 40 10 10 32 32 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 1 1 100 500 100 500 Maximum speed mm/s Maximum speed mm/s Allowable load mass (Graph (2)) Horizontal (With and without switch) 10 Load mass m (kg) 1 63 50 40 32 m 0.1 10 100 Eccentric distance + Stroke L (mm) l S l: Eccentric distance (mm) S: Stroke (mm) L Cushion

) l S l: Eccentric distance (mm) S: Stroke (mm) L Cushion Needle Adjustment Warning 1.

NO 100 200 300400 500 100 200 300400 500 Piston Speed (mm/s) Piston Speed (mm/s) Horizontal Mounting Vertical Mounting YES OK Whether retries function is still workable, without any problem. NO If retries problem arises, please reminded, not to use the cylinder. YES NO Whether determined position matches the inputted value.

Baud rate Max. bus cable length 1 Mbit/s 25 m 800 kbit/s 50 m 500 kbit/s 100 m 250 kbit/s 250 m 125 kbit/s 500 m 50 kbit/s 1000 m 20 kbit/s 2000 m 10 kbit/s 5000 m -10No.EX-OMK0006-C Bus cable and termination resistors The cables, connectors, and termination resistors used in CANopen networks shall meet the requirements defined in ISO 11898.

Cylinder extension speed: 100mm/s Meter-out needle fully open 100mm/s Return speed (Reference) Recommended circuit for high return speed When low extension speed and high return speed are desired, the following circuit using 3 ports is recommended. Tightening Torque Caution 1. The proper tightening torque for pipe fittings is as shown in the table.

How to Find the Flow Rate (at air temperature of 20C) Choke flow: when (P2 + 0.1)/(P1 + 0.1) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply

Nil S n Auto switch Thread type Nil Without auto switch (Built-in magnet) Refer to the table below for the applicable auto switch model. Type Bore size 16 Symbol M thread Rc NPT G Nil TN TF 25, 40 Stroke adjusting unit position Nil S Both ends One end Piping S is applicable for stroke adjusting units L and H.

Piston Speed Standard Stroke Bore size (mm) 16 25 40 63 20 32 50 Bore size (mm) Max. manufacturable stroke (mm) Standard stroke (mm) 80 to 500 mm/s Without stroke adjustment unit (MY3A) 80 to 1000 mm/s Without stroke adjustment unit (MY3B) 16, 20, 25 32, 40, 50 63 100, 200, 300, 400, 500, 600 700, 800, 900, 1000, 1200 1400, 1600, 1800, 2000 3000 80 to 1000 mm/s (16, 20 L unit: 80 to 800 mm

Nil Without auto switch (Built-in magnet) 12 20 32 40 50 63 12 mm 0.5 m 3 m Nil L Foot type S 1 pc. 20 mm For the applicable auto switch model, refer to the table below.