VAC for 1 minute between terminals and housing 50 M or more (500 VDC measured via megohmmeter) between terminals and housing 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Note 1) In the case of PF2W711, 3% of F.S. or less (15C to 35C, 25C reference).
1500 0 200 400 600 800 00 25 50 75 100 125 150 0 0 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AC30 Rc3/8 AC40 Rc1/2 AC40-06 Rc3/4 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 500 1000 1500 0 1000 2000 3000 00 1000 2000 3000 4000 5000 0 0 Flow rate (l/min (ANR)) Flow
time: tp = ta + tc + td [s] 0 0 250 500 750 1000 (Add settling time to the Positioning time to get the total Load Ma[g] positioning time).
MY3M Shock Absorber Specifications Piston Speed 16 to 100 10 Bore size (mm) RB 0806 RB 1412 RB 2015 RB 1007 RB 0805 Model Without stroke adjusting unit 100 to 500 mm/s 100 to 1000 mm/s 100 to 1500 mm/s (2) A unit 2.9 19.6 58.8 5.9 100 to 200 mm/s 1.0 100 to 1000 mm/s (1) Max. energy absorption (J) Stroke adjusting unit L unit and H unit 6 12 15 7 Stroke absorption (mm) 100 to 1000 mm/s 5
LEHZ/LEHZJ: 5 to 50 mm/s LEHF10: 5 to 20 mm/s LEHF20/32/40: 5 to 30 mm/s LEHS: 5 to 50 mm/s Operation at the speed outside of the range can get the lead screw caught and cause operation failure. 9. Self-lock mechanism The product keeps a gripping force due to the self-lock mechanism in the lead screw.
-Q6312-S 325 NCA325-02AQ6311-S NCA325-03-Q6311-S Material Aluminum alloy Aluminum alloy Aluminum alloy Carbon steel Aluminum alloy Aluminum alloy Bronze casting Carbon steel Carbon steel Carbon steel Carbon steel Resin NBR NBR NBR NBR NBR NBR Resin Carbon steel 150 NCA150-02AQ6308-S NCA150-03-Q6308-S 200 NCA200-02AQ6309-S NCA200-03-Q6309-S Please see below for How to Order Cylinder Tube.
Discharge time sec. 15 15 Air flow SW:1 Air flow SW:1 10 10 Air flow SW:10 Air flow SW:10 5 5 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance mm Installation distance mm IZF21-S (with Automatic cleaning unit) IZF31-S (with Automatic cleaning unit) 20 20 15 15 Discharge time sec. Discharge time sec.
Main circuit of switch OUT Black Switch operating range (mm) Cylinder speed (mm/s) Switch detecting time Ex.) Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.
VBAT10A1 S Note) A safety valve port is provided only when option R or S is selected.
1 s/2 s Output protection Output mode Response time Note 6) Voltage output Current output Short circuit protection Flow rate Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. 0.5 s/1 s/2 s (linked with the switch output) Voltage output: 1 to 5 V Output impedance: 1 k7 Analog output Output current: 4 to 20 mA Max. load impedance
V (mm/s) = Operating range of auto switch (mm) Response time of electrical device (ms) x 1000 -X Auto switch 20Example The operating range of a D-A73L reed switch on a CD85E40 cylinder is 8 mm. It is necessary to use a solenoid valve with an electrical response time of 30 ms.
Description Material 1 Rod Cover Aluminum alloy NCA200-02AQ3609-S NCA200-03-Q3609-S NCA250-02AQ3610-S NCA250-03-Q3610-S NCA325-02AQ3611-S NCA325-03-Q6311-S 2 Head Cover Aluminum alloy 3 Cylinder Tube Aluminum alloy Please See below for How to order Cylinder Tube 4 Piston Rod Carbon steel Available only as an Assembled Item.
V (mm/s) = Operating range of auto switch (mm) Response time of electrical device (ms) x 1000 -X Auto switch 20Example The operating range of a D-A73L reed switch on a CD85E40 cylinder is 8 mm. It is necessary to use a solenoid valve with an electrical response time of 30 ms.
PA06 1 262144 (Position control mode) 2400 1600 800 3000 2000 1000 2700 4200 Electronic gear denominator *3.
VBAT10A1 S Note) A safety valve port is provided only when option R or S is selected.
(CO2) [mg/L] 4.0 or less v Reference item 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s *1 In the case of [Mcm], it will be 0.003 to 0.01.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Operating pressure: 1 MPa Lateral load 1000 Stroke 100 Eccentric distance 100 80 Load weight (kg) 1000 63 10 50 40 32 25 20 1.0 100 Allowable lateral load (N) 0.1 10 100 1000 Maximum piston speed (mm/s) 100 80 63 50 40 10 32 25 20 1 0 50 100 150 200 Stroke + Eccentric distance (mm) Refer to Model Selection in Best Pneumatics No.2 for details about model selection procedure. 3 ISO Standards
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.