I f a p re s s u re g re a t e r t h a n t h e s e t p re s s u re i s re a c h e d , t h e u n i t w i l l o p e n , c l o s i n g w h e n p re s s u re i s l e s s t h a n s e t pressure.
(Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.
.: Fieldbus H System S kit 1 to 8 stations 16 Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (16 output points) Panasonic Industrial Devices SUNX Co., Ltd.: S-LINK (8 output points) DeviceNet OMRON Corp.: CompoBus/S (16 output points) OMRON Corp.: CompoBus/S (8 output points) CC-Link 1 to 4 stations 8 D side 1 to 8 stations 16 Serial transmission kit EX140 Integrated-type (For Output
of OUT1 delay time at OFF 0.01 s increment (0 to 60 s) Output mode U8 1 Y 0: HYS 1: Wind Setting of OUT2 output mode 1 R/W 1450 0X05AA 0: Normal output 1: Reverse output Setting of OUT2 output normal and reversed output 2 R/W Output type U8 0 Y OUT port pressure (OUT2) 1 R/W HYS mode set value S16 300 Y -200 ~ 2200 Setting of OUT2 output set value 2 R/W HYS mode hysteresis S16 50 Y 0 ~ 2400
Other dimensions are the same as the single type. 3-7-27 Series VZS3000 2 position single Non Plug-in Grommet: VZS3150(S)01 02 G H Manual override (Non-locking) 2-4.5 mounting hole 300 (Lead wire length) Pilot EXH port 3-Rc 1/8, 1/4 (External pilot port) Not machined ( ): Rc 1/8 L plug connector: VZS3150-L(Z)01 02 K plug connector: VZS3150-KZ01 02 300 (Lead wire length) 300 (Lead wire length
and up: Stroke length tolerance Standard Stroke Table Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Symbol 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350
70-&' r q.oo 3, 24.4 l z.9 -3r 5l 25 ,{ 25 N/A 14.3 L45 300 e.60 -g' r 2.rof're.oo t? 25.4 12.9'3r ) t 25 25 PM2050g[(S] 306 l9.0fdo ?
Stroke (mm) up to 10 up to 30 up to 75 up to 100 up to 50 up to 100 up to 300 up to 400 More than 400 up to 100 up to 300 up to 400 More than 400 up to 100 up to 300 up to 400 More than 400 up to 100 up to 300 up to 400 More than 400 up to 100 up to 300 up to 400 More than 400 Max. speed (mm/s) 7 8 9 6 10 15 Selection graph 10 11 12 13 14 15 17 16 20 25 32 The maximum speeds for 10 to 32
Station Address MECHATROLINK-III Communication Baud Rate 100 Mpbs Transmission Cycle 125 s, 250 s, 500 s, 750 s, and 1.0 ms to 4.0 ms (increments of 0.5 ms) Number of Transmission Bytes 16, 32, or 48 bytes per station Use the DIP switch S3 to select the number of words.
CUJ Specifications CU Bore size (mm) 10 16 20 25 32 Fluid Air CQS Proof pressure 1.05 MPa Max. operating pressure 0.7 MPa CQ2 Without auto switch: 10 to 70C (No freezing) Ambient and fluid temperature With auto switch: 10 to 60C (No freezing) RQ Lubricant Not applicable (Non-lube) 10, 16: 1 to 300 mm/s CQM Piston speed 20 to 32: 0.5 to 300 mm/s Cushion Rubber bumper on both ends MU Rod end
Setting (byte) 1 to 65535 10 Pn80A 1st Linear Acceleration Constant 1 2 100 reference units/s2 its/s 1 to 65535 10 Pn80B 2nd Linear Acceleration Constant 1 2 100 reference units/s2 its/s 0 to 65535 100 reference units/s Pn80C Acceleration Constant Switching Speed 1 2 0 1 to 65535 10 Pn80D 1st Linear Deceleration Constant 1 2 100 reference units/s2 its/s 1 to 65535 10 Pn80E 2nd Linear Deceleration
, 340 Reinforced pad to prevent deformation when transferring heavy or large work pieces How to Order ZP2 32 H N Pad unit Pad diameter Pad material Symbol Pad diameter 32 150 250 300 340 Symbol Material NBR Silicone rubber FKM CR N S F C 32 150 250 300 340 Note) Silicone rubber is only applicable to the 32 pad.
Mounting position Average speed Va (mm/s) Allowable load W (N): Fig.1 Over hang Ln (mm): Fig.2 Cylinder: MAX16-15 Cushion: Rubber bumper Work table mounting Mounting: Lateral wall mounting Average speed: Va=300 [mm/s] Load W=10 [N] L1=10mm L2=30mm L3=30mm Kinetic energy Enumerate the operating conditions according to mounting position and work form.
Press the S button for 1 to 3 seconds. Press the S button for 3 to 5 seconds. Press S button once.
Unit mm/s kg kg kg kg Va W Wa We Wmax K 8
Piston speed [mm/s] Maximum air consumption Q [Nl/min.] 100 125 2 300 400 500 300 400 500 80 150 200 150 200 63 50 100 100 32 40 30 40 50 30 40 50 25 20 20 20 15 15 16 10 10 8 2000 10 5 4 1500 3 1000 2 6 500 400 300 1 1 200 0.5 100 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Working pressure [MPa] 1.8-26 Series CP95 Average air consumption of compressed air cylinders and piping Thermal loss is not represented
Order Made 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 Symbol Specifications/Descriptions 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 XA 100 Change of rod end shape 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450,
ES20-150 B Stainless Steel Cylinder Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80,100 For use in environments with water spray such as food processing machines Stainless Steel Cylinder Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Uses grease for food processing machines that meets FDA (U.S.
Without auto switch CG5 L N 25 S R 100 CDG5 L N 25 S 100 G5BAL R With auto switch Built-in magnet Number of auto switches 2 pcs. 1 pc. n pcs.
RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual