Calculation of applied lateral load The lateral load F equals the total load of the workpiece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) CC 70 Lateral load F (N) RB 60 0.4 MPa 50 J 40 2.

Rod clevis: GKM (ISO 8140) l1 [mm] Bore size [mm] Part no. e b d f h11 (Shaft) f H9 (Hole) l1 c (Min.) a (Max.) 32 GKM10-20 M10 x 1.25 10+0.5 +0.15 40 10 10 52 20 20 40 GKM12-24 M12 x 1.25 12+0.5 +0.15 48 12 12 62 24 24 50, 63 GKM16-32 M16 x 1.5 16+0.5 +0.15 64 16 16 83 32 32 80, 100 GKM20-40 M20 x 1.5 20+0.5 +0.15 80 20 20 105 40 40 125 GKM30-54 M27 x 2 30+0.5 +0.15 110 30 30 148 54 55

(ISE70 series only) prevent moisture from getting into the piping. -30No.PS-OMH0003-F Reference No. Problem Possible cause Investigation method Countermeasure Check if the power supply voltage is within the range of 12 to 24 VDC. (ripple 10%) Supply power supply voltage of 12 to 24 VDC (ripple 10%) Incorrect power supply Check the wiring to the power supply.

How to Order JA 40 F 14-150 Option Mounting type None Nil High temperature specifications 5 to 100C Nil F L Basic type Flange type Foot type Applicable bore size (mm) X11 Symbol Applicable bore size (mm) Model 6 10 15 20 30 40 63 80 100 140 160 6 10 10, 15 20 25, 32 40 50, 63 80 100 125, 140 160 Thread nominal size (Standard) Nominal thread size Applicable cylinder nominal thread size Standard

Applicable model HRR012/018--10-T/MT*1 HRR012/018/024/030--20-T HRR012/018/024/030--20-MT1 Pump Rated flow (50/60 Hz)2, 3 L/min 7 (0.36 MPa)/10 (0.42 MPa) 10 (0.42 MPa)/14 (0.40 MPa) 10 (0.32 MPa)/14 (0.32 MPa) Maximum pump head (50/60 Hz) m 50 50 50 Output W 350 550 Circuit protector A 15 15 (10 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity4 W The cooling

Bore size B DA DB DL DU DC DX DE DO DR DT DS DH Z DD H10 32 219 40 237 50 268 63 280 80 351 100 371 MB-B03 32 46 42 32 22 10 44 14 62 9 6.6 15 7 33 213 10+0.058 0 40 52 42 32 22 10 44 14 62 9 6.6 15 7 33 231 10+0.058 0 MB-B05 50 65 53 43 30 11.5 60 20 81 10.5 9 18 8 45 260 14+0.070 0 63 75 53 43 30 11.5 60 20 81 10.5 9 18 8 45 272 14+0.070 0 MB-B08 80 95 73 64 45 14 86 30 111 12.5 11 22 10

hole) 1.5 IDF-TR500-1 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA IDF-TR500-2 Output sealing C A Output outlet Input fuse 5A Voltage selector B 220V INPUT 200V 230V 240V E D 4-5.5 x 10 long hole F Input cord 2 m Transformer part no.

(mm) 500st 300st 400st 1 1 0.5 400st 300st 200st 300st 0.5 0.5 200st 100st 200st 100st 100st 75st 75st 0 0 0 0 0 0 10 20 30 40 50 20 40 60 80 100 10 20 30 40 50 60 70 Allowable end load F (N) Allowable end load F (N) Allowable end load F (N) MGGM 40Stroke 3 (Slide bearing type) 2.5 Deflection Y (mm) 800st 2 700st 600st 1.5 500st 1 300st 400st st: Stroke (mm) 0.5 100st 200st 0 0 20 40 60

(mm) RB Note) H OA A B C D E F W I Y J K L M N OB Q RA TN TF 10 39.5 M3 x 0.5 M4 x 0.7 10 to 40 31.5 6 6 ( 5.8) 29 5.5 38 4 5 5 8 20 3.5 6.5 14.5 7 16 44 M4 x 0.7 M6 x 1.0 10 to 60 34 8 8 ( 7.8) 36 5.5 47 7 5 7 10 25.5 5.4 9 18 10 20 47.5 M5 x 0.8 M6 x 1.0 10 to 60 37.5 10 10 ( 9.8) 40 5.5 52 7 6 8 10 28 5.4 9 19.5 10 25 10 to 50, 75, 100 54 M6 x 1.0 M6 x 1.0 42 12 12 (11.8) 45 8.5

Through-hole/CQ2YB, CDQ2YB Both ends tapped/CQ2YA, CDQ2YA CDQ2YA Both ends tapped (mm) Bore size (mm) O1 R O1 thread R R M6 x 1.0 10 32 M6 x 1.0 10 40 M8 x 1.25 14 50 H thread effective depth C U 4-N through 8-O counter bore Q F 2-P (Port size) (Rc, NPT, G) I 22 D M E Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J L B + Stroke A + Stroke Rod end male thread H1 Auto switch

Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.

Internal Grip External Grip MHKL2-12S MHKL2-12C 20 15 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 15 Pressure 0.6 MPa MHZ 10 0.5 MPa 0.5 MPa 10 MHF 0.4 MPa 0.4 MPa 5 5 MHL 0.3 MPa 0.3 MPa F F 0 0 MHR 10 20 30 40 50 10 20 30 40 50 10 20 30 40 50 Note) In case of single acting type, the value is for stroke center.

Internal Grip External Grip MHKL2-12S MHKL2-12C 20 15 Gripping force (N) Gripping force (N) Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 15 Pressure 0.6 MPa MHZ 10 0.5 MPa 0.5 MPa 10 MHF 0.4 MPa 0.4 MPa 5 5 MHL 0.3 MPa 0.3 MPa F F 0 0 MHR 10 20 30 40 50 10 20 30 40 50 10 20 30 40 50 Note) In case of single acting type, the value is for stroke center.

calculation m2 = d x e x f x Relative density m2 = 4 x 5 + 6 x 2.7 x 10-6 = 3.24 x 10-4 (kg) Inertial moment around Z2 axis Z2 = {m2 (d2 x e2) / 12} x 10-6 Z2 = {3.24 x 10-4 x (42 + 52) / 12} x 10-6 = 1.11 x 10-9 (kg.m2) = 1.11 x 10-9 + 3.24 x 10-4 x 23.52 x 10-6 = 0.18 x 10-6 (kg.m2) Inertial moment around Z axis B = Z2 x m2r22 x 10-6 B Thus, the total inertial moment is = A + B = 0.20

C D E F H RB I J K L M N OB Q RA W Y M4 x 0.7 4 14.5 7 5 M3 x 0.5 10 to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to 60 44 34 8 8 36 5.5 16 47 7 10 25.5 5.4 9 M6 x 1.0 7 19.5 10 6 M5 x 0.8 10 to 60 47.5 37.5 10 10 40 5.5 20 52 8 10 28 5.4 9 M6 x 1.0 7 23 10 49.5 7 M6 x 1.0 10 to 50, 75, 100 54 42 12 12 45 8.5 25 60 4.5 10 12 34 5.5 9 M6 x 1.0 7 26 10

1 6 2 1 3 G1/8 G1/8 3 7 NPN2 PNP2 A B 4 L 7 5 SI N 1 2 3 1 2 3 4 5 6 S 6 7 8 4 5 6 6 7 8 T 1F 2GH 3ISO1179-1 4 5kPa 61 7 88 (10 ) 9DIN 101 1 2 2 -8No.PS-OMT0001CN-E 2 B 2 F 0.010.03mm 0.020.15mm 0.050.30mm G H DC24V AC100V AC110V 10 1 10 2 Rc1/8 4 1 C 2 6 10 N 3 10 0.4MPaMPa 0 G1/8 F G1/8 3 1 11 0.4MPaMPa 0.2MPaMPa 0.2MPaMPa 2 3 C Rc1/4 F 12 G1/4 4

piece mass (kg) Work piece mass (kg) 5 10 10 5 5 1 1 1 0.5 5 40 30 20 10 5 40 30 20 10 5 40 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) Transfer speed V (m/min) 1420 Escapements Series MIW/MIS Model Selection Allowable lateral load MIW8 MIS8 MIW12 MIS12 0.7 MPa 70 0.7 MPa 30 0.6 MPa 0.6 MPa 0.5 MPa 60 0.4 MPa 0.5 MPa 0.3 MPa 0.4 MPa Lateral load F (N) Lateral load F (N) 50

UPPER AND LOWER LIMIT ARISES -9-2 FIG. 10-1 MOISTURE AIR DIAGRAM -10-3 vi Contents Table List Page No.

kPa ONOFF ISE20A0.050 MPa ZSE20A5.1 kPa ZSE20AF5.0 kPa 1.5 ms OUT1 ON OUT1 OFF -28No.PS-OMU0002CN-D [F 2] OUT2 34 [F 1] OUT1 [F 3] 36 0 ms [F 4] 37 [F 5] FUNC 39 [F 6] 41 0% [F10] 42 std() [F11] 48 1000 [F80] 49 OFF [F81] 50 OFF [F82] 52 A [F90] 53 OFF [F96] 55 [F97] 56 OFF [F98] 58 () [F99] 60 OFF XY "---" -29No.PS-OMU0002CN-D [F 0] (kPa/MPa) <> [F 0] [F 0] ZSE20AF