Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 /min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 F.R.L.
Width across flats Min. bore size Model T Connection port size Weight g Effective area mm2 L2 L1 KKA3P-01F-1 Rc 1/8 23.2 9.6 14 -02F-1 1/8 T Rc 1/4 6.0 22.6 16.0 30.3 20.2 17 -03F-1 Rc 3/8 32.0 26.2 19 KKA4P-02F-1 Rc 1/4 29.7 20.0 17 -03F-1 1/4 Rc 3/8 8.0 40.2 18.9 34.0 25.8 19 -04F-1 Rc 1/2 39.4 46.1 24 L2 H KKA6P-03F-1 Rc 3/8 30.9 34.3 22 L1 -04F-1 1/2 Rc 1/2 11.0 76.0 20.4 39.6 50.0 24
Common PS port q Stations Note 1) Symbol w System (Port combination) Note 2) Stations Symbol Standard Port System 01 02 1 station Common PV port 2 stations Vacuum pump system Common PV: 8, Common PS: 6 Note 3) P P 10 10 stations Metric size Note 1) In case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.
Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SS3Y1 31 05 Stations 02 2 stations P R 20 20 stations R port M5 x 0.8 P port M5 x 0.8 Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.
= 26 x n + 12 2 76 64 3 102 90 4 128 116 5 154 142 6 180 168 7 206 194 8 232 220 9 258 246 10 284 272 L L1 L2 [ ]: With light/surge voltage suppressor 4-7-8
List part numbers of the installed valve and option in required station location separately under manifold part number. 2.1-10 Series SY100 Common SUP/Common EXH 30 Type How to Order Applicable solenoid valve (1) SS3Y1 30 05 F SY113-l-M3 SY113A-l-M3 Stations 02 Applicable blank plate assembly 2 stations ... ...
NARM 2500 05 A 02 G1 Optimal for central pressure control. Accessory Regulator for manifold Pressure easily set using the new handle. One-touch lock system.
Type 31 How to Order Applicable solenoid valve Note) SY113--M3 SY113A--M3 SY123--M3 SY123A--M3 Applicable blanking plate assembly SY100-77-1A SYJ SS3Y1 31 05 VK Stations VZ 02 2 stations P R 20 VT 20 stations R port VP M5 x 0.8 P port M5 x 0.8 VG Note) SY113(A) and SY123(A) cannot be mounted on the same manifold.
SS5Y3-42-02-C6 1 unit SY3140-5LOZ 2 units o Cable assembly for output entry. EX510-VW10S 1 pc. !0 Output unit . EX510-DYN3 1 unit !1 2 port solenoid valve . VX2120-02-5GS1 1 pc. Two branch connectors are attached to the manifold including the SI unit and two are attached to the input unit and the output unit respectively.
VE 3 Bleed port Model (Made to Order) Pressure range Note) Indication unit Connection thread VY1 Note Model MPa G43-2-01 to 02-X2 G43-4-01 to 02-X2 G43-6-01-X2 G43-7-01 to 02-X2 G43-10-01 to 02-X2 G43-2-01 to 02-X3 G43-4-01 to 02-X3 G43-6-01-X3 G43-7-01 to 02-X3 G43-10-01 to 02-X3 G43-2-01 to 02-X4 G43-4-01 to 02-X4 G43-6-01-X4 G43-7-01 to 02-X4 G43-10-01 to 02-X4 0 to 0.2 0 to 0.4 0 to 0.6
R Right side (PV port on the right side) L Left side (PV port on the left side) 02 2 B Both sides (PV port on both sides) Nil All stations 1 Station 1 only 08 8 1 Viewed from the front side of valve unit, confirm the port location on the right and/or left side. 2 EXH ports are released to atmospheric pressure in both sides.
Output 1 Output 2 A B C Dimensions D3 D2 L5 M2 IN L3 L2 L4 OUT IN D1 M1 M1 Applicable tube dia. d L1 Metric Size Weight (g) Model d D1 D2 L3 L2 D3 L1 L4 L5 M1 M2 VR1211F-23 3.2 11.4 8.4 52 6.2 25.7 36.1 17.5 12.7 12.9 26.4 14.8 VR1211F-04 4 12.8 10.4 56 26.6 38.5 21.9 15.7 15.8 30.4 6.8 VR1211F-06 6 12.8 12.8 53.2 28.8 41.9 25.2 16.8 16.8 25.0 Inch Size Weight (g) Model d D1 D2 L3 L2 D3 L1
(max. 20 stations) Valve stations Supply/Exhaust block assembly fitting specifications Note Symbol 02 Stations 2 stations Double wiring specification Straight Nil L B Supply/Exhaust block assembly mounting position 08 02 Elbow fitting (upward) 8 stations Elbow fitting (downward) 2 stations Specified wiring (up to 16 solenoids are possible) U D B M U Side (2 to 10 stations) D Side (2 to