SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-02-L2-MA"

41.7 40.4 35.4 15.2 18.5 15 11 R(PT)1/4 17 34.4 29.4 18.5 55 28.2 46.5 19.7 10 ASD430F-02-10S 18.5 21 58 31 49.3 6 ASD530F-02-06S 12.8 17 74 25.2 48.3 20.3 8 ASD530F-02-08S 15.2 18.5 76 28.2 51.3 41.9 46.9 48.8 43.8 23 19.8 15.4 R(PT)1/4 19 42.8 37.8 10 ASD530F-02-10S 21 18.5 80 32.6 54.1 23.1 12 ASD530F-02-12S 22 20.9 83 34.4 55.9 6 ASD530F-03-06S 17 74 12.8 25.2 48.3 20.3 8 ASD530F-03-08S

Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

Body A 1 Brass Electroless nickel plated Body B 2 Brass Electroless nickel plated Valve 3 Aluminum O-ring 4 HNBR Spring 5 Stainless steel Pad side Element 6 BC ZP2V-AZP2V-BGasket 7 NBR + Stainless steel 63 Series ZP2V Vacuum Saving Valve Dimensions Vacuum generator side Vacuum generator side M2 M2 H1 H1 Vacuum generator side L2 L1 L3 L2 M2 H1 L2 L33 (L4) (L4) No.0.8 No.0.8 L1 L3 L2 L3

LECSB1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.)

LECSB1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.)

LECSB1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.)

Knuckle Pin L2 Material: Carbon steel (mm) Pivot Bracket (Order separately) Applicable bore (mm) Applicable retaining ring 20 25, 32 40 50, 63 80 100 L2 Dd9 m t d Part no.

Y60 Interface G36-10-01 G36-10-01G46-10-02 G46-10-02 G46-10-02 G46-10-02 G46-10-02 G36-10-01 1.0MPa G27-10-R1 Pressure gauge (G27-10-R1)(4) G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G36-2-01 0.2MPa AD43 AD43 AD44 AD44 AD44 AD44 AD44 N.O.

M = W x 9.8 (Ln + An)/1000 Correction value of moment center position distance An: Table (3) Ma = K Mmax Workpiece mounting coefficient K: Fig. (3) Allowable moment coefficient : Graph (2) Maximum allowable moment Mmax: Table (4) 2 = M/Ma Find the allowable static moment Ma (Nm). Find the load factor 2 of the static moment.

/Input unit manifold Input device supply current Approx. 5 mA Rated input current Green LED (Lights when power is turned ON.)

MHW Position where light turns ON -X MRHQ 0.3 to 0.5 mm MA Position to be secured DNote 1) It is recommended that gripping of a workpiece be performed close to the center of the finger stroke.

VVEX2-2-5-02 VEX1233-G VEX1-17 4 pieces 1 piece AP100 Note) Not conforming to ISO1179-1.

Series VC 2 3 4 Class 2 Class 3 Class 4 OUT port size VDW Port size 1/8 (6A) Symbol 01 02 Stations Uside D side 1/4 (8A) Material VQ Stations 1 2 3 4 5 n 02 2 stations All IN ports are 3/8.

GDM2A-L1 GDM2A-L1 GDM2A-L2 GDM2A-L2 GDM2A-L2 GDM2A-L2 GDM2A-L5 GDM2A-L15 24 VDC 100 VAC 12 VDC 110 VAC 100 VAC 200 VAC 110 VAC 220 VAC With light 200 VAC 230 VAC With light 220 VAC 240 VAC 230 VAC 24 VAC 240 VAC 48 VAC 24 VAC 48 VAC Select an appropriate DIN connector suitable for the coil insulation type.

1/4, 3/8 61 68 26 5.5 56 45.5 5.25 25 13.2 20.6 (N)AS3000-02, 03 Courtesy of Steven Engineering, Inc. !

AS321F-02-06 AS221F-02-11 6 3/8" 12.8 17 35.3 21 18.8 44.5 27.8 36 60 18.5 39.3 AS321F-02-08 AS321F-02-07 8 1/4" 15.2 18.5 27.8 17 41 29.5 39.3 63 13.2 60 48.3 43.3 42.8 37.8 21.3 23 AS321F-02-10 AS321F-02-09 10 5/16" 23 18.5 21 43.3 31.8 37.8 67 18.5 63 29.5 43.3 42.8 15.2 41 21.3 48.3 AS321F-02-12 AS321F-02-11 12 3/8" 20.9 22 31.8 44.3 32.8 69 43.3 21 67 17.9 19 19 AS321F-03-06 AS321F-

Supply/exhaust block assembly, end plate R, power block, or other EX9 series general purpose output block EX500 series PWR PWR COM PWR PWR 1 0 1 0 1 0 L2 L3 L1 1 0 1 0 1 0 1 0 Power block or EX9 series general purpose output block SI unit for general purpose output block ( EX500-Q 02 ) Tie-rod: 4 pcs. 1 0 1.5 66 Mounting hole for: M4 places 34 35 Pin allgnment and connection drawing of the