Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27

How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)

Setting range 100.0 to 100.0kPa 101.3 to 101.3kPa 1.000 to 1.000MPa Set pressure range 100.0 to 100.0kPa 10.0 to 101.3kPa 0.1 to 1.000MPa Lead wire length Nil L 0.6m 3m 2 High Precision Digital Pressure Switch Dimensions ZSE40(F)/ISE40 01 T1 20 30 M5 x 0.8 thread depth 5 MPa 30 20 OUT2 OUT1 SET Width across flats 12 2-M3 x 0.5 thread depth 4 6.4 18.35 Atmospheric release port Lead wire length

For vacuum/compound pressure : kPa For positive pressure : MPa Setting range Set pressure range Lead wire length 100.0 to 100.0kPa 101.3 to 101.3kPa 100.0 to 100.0kPa Nil 0.6m 3m 10.0 to 101.3kPa 0.1 to 1.000MPa L 1.000 to 1.000MPa 2 High Precision Digital Pressure Switch Dimensions ZSE40(F)/ISE40 01 T1 20 30 M5 x 0.8 thread depth 5 MPa 30 20 OUT2 OUT1 SET Width across flats 2-M3 x 0.5 thread

V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Model LW53 3 Way Normally Closed Piped Exhaust LW53GG8XGB LW53GH8XGB (G or L) LW53GJ8XGB (G or L) LW53GV8XGB (G or L) LW53GK8XGB (G or L) LW53HH8XGB (G or L) LW53HJ8XGB (G or L) LW53HV8XGB (G or L) LW53HK8XGB (G or L) LW53JJ8XGB (G or L) LW53JV8XGB (G or L) LW53JK8XGB (G or L) LW53VV8XGB (G or L) LW53VK8XGB

Minimum measured Maximum measured Minimum measured Maximum measured Minimum measured Maximum measured Part nos. flow rate value [l/min] Part nos. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2

Minimum measured Maximum measured Minimum measured Maximum measured Minimum measured Maximum measured Part nos. flow rate value [l/min] Part nos. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2